메뉴 건너뛰기




Volumn 8, Issue 4, 2007, Pages 28-44

Using an onboard kilovoltage imager to measure setup deviation in intensity-modulated radiation therapy for head-and-neck patients

Author keywords

Head and neck; IGRT; IMRT; Setup error

Indexed keywords


EID: 38049185164     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v8i4.2439     Document Type: Article
Times cited : (20)

References (12)
  • 1
    • 0035577194 scopus 로고    scopus 로고
    • The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer
    • Manning MA, Wu Q, Cardinale RM, et al. The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer. Int J Radiat Oncol Biol Phys. 2001;51(5):1400-1409.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , Issue.5 , pp. 1400-1409
    • Manning, M.A.1    Wu, Q.2    Cardinale, R.M.3
  • 2
    • 0038738053 scopus 로고    scopus 로고
    • Systematic setup errors for IMRT in the head and neck region: Effect on dose distribution
    • Samuelsson A, Mercke C, Johansson KA. Systematic setup errors for IMRT in the head and neck region: effect on dose distribution. Radiother Oncol. 2003;66(3):303-311.
    • (2003) Radiother Oncol , vol.66 , Issue.3 , pp. 303-311
    • Samuelsson, A.1    Mercke, C.2    Johansson, K.A.3
  • 4
    • 0028938971 scopus 로고
    • Accuracy of field alignment in radiotherapy of head and neck cancer utilizing individualized face mask immobilization: A retrospective analysis of clinical practice
    • Hess CF, Kortmann RD, Jany R, Hamberger A, Bamberg M. Accuracy of field alignment in radiotherapy of head and neck cancer utilizing individualized face mask immobilization: a retrospective analysis of clinical practice. Radiother Oncol. 1995;34(1):69-72.
    • (1995) Radiother Oncol , vol.34 , Issue.1 , pp. 69-72
    • Hess, C.F.1    Kortmann, R.D.2    Jany, R.3    Hamberger, A.4    Bamberg, M.5
  • 5
    • 0034212293 scopus 로고    scopus 로고
    • Setup error in radiotherapy: On-line correction using electronic kilovoltage and megavoltage radiographs
    • Pisani L, Lockman D, Jaffray D, Yan D, Martinez A, Wong J. Setup error in radiotherapy: on-line correction using electronic kilovoltage and megavoltage radiographs. Int J Radiat Oncol Biol Phys. 2000;47(3):825-839.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , Issue.3 , pp. 825-839
    • Pisani, L.1    Lockman, D.2    Jaffray, D.3    Yan, D.4    Martinez, A.5    Wong, J.6
  • 6
    • 3042522622 scopus 로고    scopus 로고
    • Implanted gold markers for position verification during irradiation of head and neck cancers: A feasibility study
    • van Asselen B, Dehnad H, Raaijmakers CP, Lagendijk JJ, Terhaard CH. Implanted gold markers for position verification during irradiation of head and neck cancers: a feasibility study. Int J Radiat Oncol Biol Phys. 2004;59(4):1011-1017.
    • (2004) Int J Radiat Oncol Biol Phys , vol.59 , Issue.4 , pp. 1011-1017
    • van Asselen, B.1    Dehnad, H.2    Raaijmakers, C.P.3    Lagendijk, J.J.4    Terhaard, C.H.5
  • 7
    • 1642266409 scopus 로고    scopus 로고
    • Evaluation of intrafraction patient movement for CNS and head and neck IMRT
    • Kim S, Akpati HC, Kielbasa JE, et al. Evaluation of intrafraction patient movement for CNS and head and neck IMRT. Med Phys. 2004;31(3):500-506.
    • (2004) Med Phys , vol.31 , Issue.3 , pp. 500-506
    • Kim, S.1    Akpati, H.C.2    Kielbasa, J.E.3
  • 9
    • 33646924615 scopus 로고    scopus 로고
    • Magnitude and clinical relevance of translational and rotational patient setup errors: A cone-beam CT study
    • Guckenberger M, Meyer J, Vordermark D, Baier K, Wilbert J, Flentje M. Magnitude and clinical relevance of translational and rotational patient setup errors: a cone-beam CT study. Int J Radiat Oncol Biol Phys. 2006;65(3):934-941
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , Issue.3 , pp. 934-941
    • Guckenberger, M.1    Meyer, J.2    Vordermark, D.3    Baier, K.4    Wilbert, J.5    Flentje, M.6
  • 10
    • 31844439099 scopus 로고    scopus 로고
    • Six dimensional analysis with daily stereoscopic X-ray imaging of intrafraction patient motion in head and neck treatments using five points fixation masks
    • Linthout N, Verellen D, Tournel K, Storme G. Six dimensional analysis with daily stereoscopic X-ray imaging of intrafraction patient motion in head and neck treatments using five points fixation masks. Med Phys. 2006;33(2):504-513.
    • (2006) Med Phys , vol.33 , Issue.2 , pp. 504-513
    • Linthout, N.1    Verellen, D.2    Tournel, K.3    Storme, G.4
  • 11
    • 33645371783 scopus 로고    scopus 로고
    • Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy
    • Zhang L, Garden AS, Lo J, et al. Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy. Int J Radiat Oncol Biol Phys. 2006,64(5):1559-1569.
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , Issue.5 , pp. 1559-1569
    • Zhang, L.1    Garden, A.S.2    Lo, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.