메뉴 건너뛰기




Volumn 38, Issue 2, 2008, Pages 105-118

Contrast harmonic ultrasound and indocyanine-green fluorescence video angiography for evaluation of dermal and subdermal microcirculation in free parascapular flaps

Author keywords

Contrast harmonic ultrasound; Fluorescence angiography; Microcirculation; Parascapular flaps

Indexed keywords

CONTRAST MEDIUM; INDOCYANINE GREEN; SONOVUE;

EID: 38049087209     PISSN: 13860291     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (19)

References (33)
  • 2
    • 33746435297 scopus 로고    scopus 로고
    • The effect of ischemia and reperfusion on microvascular function: A human in vivo comparative study with conduit arteries
    • T. Gori, G. Di Stolfo, S. Sicuro, S. Dragoni, J.D. Parker and S. Forconi, The effect of ischemia and reperfusion on microvascular function: A human in vivo comparative study with conduit arteries, Clin. Hemorheol. Microcirc. 35 (2006), 169-173.
    • (2006) Clin. Hemorheol. Microcirc , vol.35 , pp. 169-173
    • Gori, T.1    Di Stolfo, G.2    Sicuro, S.3    Dragoni, S.4    Parker, J.D.5    Forconi, S.6
  • 3
    • 22744453832 scopus 로고    scopus 로고
    • Vascularisation and perfusion of hepatocellular carcinoma: Assessment with contrast-enhanced ultrasound using perflutren protein-type A microspheres
    • E.M. Jung, R. Kubale and K.-P. Jungius, Vascularisation and perfusion of hepatocellular carcinoma: assessment with contrast-enhanced ultrasound using perflutren protein-type A microspheres, Clin. Hemorheol. Microcirc. 33 (2005), 63-73.
    • (2005) Clin. Hemorheol. Microcirc , vol.33 , pp. 63-73
    • Jung, E.M.1    Kubale, R.2    Jungius, K.-P.3
  • 4
    • 33646533729 scopus 로고    scopus 로고
    • Vascularisation of liver tumors - preliminary results with coded harmonic angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison®)
    • E.M. Jung, R. Kubale, K.-P. Jungius, W. Jung, M. Lenhart and D.-A. Clevert, Vascularisation of liver tumors - preliminary results with coded harmonic angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison®), Clin. Hemorheol. Microcirc. 34 (2006), 483-497.
    • (2006) Clin. Hemorheol. Microcirc , vol.34 , pp. 483-497
    • Jung, E.M.1    Kubale, R.2    Jungius, K.-P.3    Jung, W.4    Lenhart, M.5    Clevert, D.-A.6
  • 7
    • 9644272880 scopus 로고    scopus 로고
    • Multi-frequency harmonic arrays: Initial experience with a novel transducer concept for nonlinear contrast imaging
    • F. Forsberg, W.T. Shi, B. Jadidian and A.A. Winder, Multi-frequency harmonic arrays: initial experience with a novel transducer concept for nonlinear contrast imaging, Ultrasonics 43 (2004), 79-85.
    • (2004) Ultrasonics , vol.43 , pp. 79-85
    • Forsberg, F.1    Shi, W.T.2    Jadidian, B.3    Winder, A.A.4
  • 8
    • 0141894125 scopus 로고    scopus 로고
    • Free of speckle ultrasonic imaging of soft tissue with account of second harmonic signal
    • N. Kharin, D. Driscoll and W. Tobocman, Free of speckle ultrasonic imaging of soft tissue with account of second harmonic signal, Phys. Med. Biol. 48 (2003), 3239-3260.
    • (2003) Phys. Med. Biol , vol.48 , pp. 3239-3260
    • Kharin, N.1    Driscoll, D.2    Tobocman, W.3
  • 9
    • 0036893087 scopus 로고    scopus 로고
    • Advantages of real-time spatial compound sonography of the musculoskeletal system versus conventional sonography
    • D.C. Lin, L.N. Nazarian, P.L. O'Kane, J.M. McShane, L. Parker and C.R. Merritt, Advantages of real-time spatial compound sonography of the musculoskeletal system versus conventional sonography, AJR 179 (2002), 1629-1631.
    • (2002) AJR , vol.179 , pp. 1629-1631
    • Lin, D.C.1    Nazarian, L.N.2    O'Kane, P.L.3    McShane, J.M.4    Parker, L.5    Merritt, C.R.6
  • 12
    • 21744458729 scopus 로고    scopus 로고
    • Vascular imaging with contrast-enhanced sonography for experimental use
    • M. Krix, H.U. Kauczor and S. Delorme, Vascular imaging with contrast-enhanced sonography for experimental use, Radiologe 45 (2005), 552-559.
    • (2005) Radiologe , vol.45 , pp. 552-559
    • Krix, M.1    Kauczor, H.U.2    Delorme, S.3
  • 13
    • 1642317459 scopus 로고    scopus 로고
    • Low mechanical index contrast-enhanced ultrasound better reflects high arterial perfusion of liver metastases than arterial phase computed tomography
    • M. Krix, F. Kiessling, M. Essig, F. Herth, A. Karcher, M. Le-Huu, H.U. Kauczor and S. Delorme, Low mechanical index contrast-enhanced ultrasound better reflects high arterial perfusion of liver metastases than arterial phase computed tomography, Invest. Radiol. 39 (2004), 216-222.
    • (2004) Invest. Radiol , vol.39 , pp. 216-222
    • Krix, M.1    Kiessling, F.2    Essig, M.3    Herth, F.4    Karcher, A.5    Le-Huu, M.6    Kauczor, H.U.7    Delorme, S.8
  • 14
    • 9644283317 scopus 로고    scopus 로고
    • Quantification of perfusion of liver tissue and metastases using a multi-vessel model for replenishment kinetics of ultrasound contrast agents
    • M. Krix, C. Planthow, F. Kiessling, F. Herth, A. Karcher, M. Essig, H. Schmitteckert, H.U. Kauczor and S. Delorme, Quantification of perfusion of liver tissue and metastases using a multi-vessel model for replenishment kinetics of ultrasound contrast agents, Ultrasound Med. Biol. 30 (2004), 1355-1363.
    • (2004) Ultrasound Med. Biol , vol.30 , pp. 1355-1363
    • Krix, M.1    Planthow, C.2    Kiessling, F.3    Herth, F.4    Karcher, A.5    Essig, M.6    Schmitteckert, H.7    Kauczor, H.U.8    Delorme, S.9
  • 15
    • 0242557653 scopus 로고    scopus 로고
    • Quantification of tissue perfusion with novel ultrasound methods
    • M. Krix , H.U. Kauczur and S. Delorme, Quantification of tissue perfusion with novel ultrasound methods, Radiologe 43 (2003), 823-830.
    • (2003) Radiologe , vol.43 , pp. 823-830
    • Krix, M.1    Kauczur, H.U.2    Delorme, S.3
  • 16
    • 0042844541 scopus 로고    scopus 로고
    • Blood flow quantification with contrast-enhanced US: "entrance in the section" phenomenon-phantom and rabbit study
    • O. Lucidarme, S. Franchi-Abella, J.M. Correas, S.L. Bridal, E. Kurtisovski and G. Berger, Blood flow quantification with contrast-enhanced US: "entrance in the section" phenomenon-phantom and rabbit study, Radiology 228 (2003), 473-479.
    • (2003) Radiology , vol.228 , pp. 473-479
    • Lucidarme, O.1    Franchi-Abella, S.2    Correas, J.M.3    Bridal, S.L.4    Kurtisovski, E.5    Berger, G.6
  • 18
    • 0036460692 scopus 로고    scopus 로고
    • Intraoperative evaluation of skin-flap viability using laser-induced fluorescence of indocyanine green
    • C. Holm, M. Mayr, E. Hofter, A. Becker, U.J. Pfeiffer and W. Mühlbauer, Intraoperative evaluation of skin-flap viability using laser-induced fluorescence of indocyanine green, Br. J. Plast. Surg. 55 (2002), 635-644.
    • (2002) Br. J. Plast. Surg , vol.55 , pp. 635-644
    • Holm, C.1    Mayr, M.2    Hofter, E.3    Becker, A.4    Pfeiffer, U.J.5    Mühlbauer, W.6
  • 19
    • 9644291409 scopus 로고    scopus 로고
    • Indocyanine-green fluorescence video angiography used clinically to evaluate tissue perfusion in microsurgery
    • H. Mothes, T. Dönicke, R. Friedel, M. Simon, E. Markgraf and O. Bach, Indocyanine-green fluorescence video angiography used clinically to evaluate tissue perfusion in microsurgery, J. Trauma 57 (2004), 1018-1024.
    • (2004) J. Trauma , vol.57 , pp. 1018-1024
    • Mothes, H.1    Dönicke, T.2    Friedel, R.3    Simon, M.4    Markgraf, E.5    Bach, O.6
  • 20
    • 0032978923 scopus 로고    scopus 로고
    • Efficacy of conventional monitoring techniques in free tissue transfer: An 11-year experience in 750 consecutive cases
    • J.J. Disa, P.G. Cordeiro and D.A. Hidalgo, Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases, Plast. Reconstr. Surg. 104 (1999), 97-101.
    • (1999) Plast. Reconstr. Surg , vol.104 , pp. 97-101
    • Disa, J.J.1    Cordeiro, P.G.2    Hidalgo, D.A.3
  • 21
    • 33645240821 scopus 로고    scopus 로고
    • Review of monitoring free muscle flap transfers in reconstructive surgery: Role of 99mTc sestamibi scintigraphy
    • H. Top, A. Sarikaya, A.C. Aygit, E. Benlier and M. Kiyak, Review of monitoring free muscle flap transfers in reconstructive surgery: role of 99mTc sestamibi scintigraphy, Nucl. Med. Commun. 27 (2006), 91-98.
    • (2006) Nucl. Med. Commun , vol.27 , pp. 91-98
    • Top, H.1    Sarikaya, A.2    Aygit, A.C.3    Benlier, E.4    Kiyak, M.5
  • 23
    • 33646503650 scopus 로고    scopus 로고
    • Noninvasive assessment of cutaneous vascular function in vivo using capillaroscopy, plethysmography and laser-Doppler instruments: Its strengths and weaknesses
    • G.B. Yvonne-Tee, A.H. Rasool, A.S. Halim and A.R. Rahman, Noninvasive assessment of cutaneous vascular function in vivo using capillaroscopy, plethysmography and laser-Doppler instruments: its strengths and weaknesses, Clin. Hemorheol. Microcirc. 34 (2006), 457-473.
    • (2006) Clin. Hemorheol. Microcirc , vol.34 , pp. 457-473
    • Yvonne-Tee, G.B.1    Rasool, A.H.2    Halim, A.S.3    Rahman, A.R.4
  • 24
    • 33645318156 scopus 로고    scopus 로고
    • Color Doppler ultrasonography is a reliable predictor of free tissue transfer outcomes in head and neck reconstruction
    • A.N. Khalid, S.A. Quraishi, W.A. Zang, J.L. Chadwick and B.C. Stack, Color Doppler ultrasonography is a reliable predictor of free tissue transfer outcomes in head and neck reconstruction, Otolaryng. Head Neck Surg. 134 (2006), 635-638.
    • (2006) Otolaryng. Head Neck Surg , vol.134 , pp. 635-638
    • Khalid, A.N.1    Quraishi, S.A.2    Zang, W.A.3    Chadwick, J.L.4    Stack, B.C.5
  • 25
    • 0032054550 scopus 로고    scopus 로고
    • The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery
    • M.S. Thorniley, J.S. Sinclair, N.J. Barnett, C.B. Shurey and C.J. Green, The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery, Br. J. Plast. Surg. 51 (1998), 218-226.
    • (1998) Br. J. Plast. Surg , vol.51 , pp. 218-226
    • Thorniley, M.S.1    Sinclair, J.S.2    Barnett, N.J.3    Shurey, C.B.4    Green, C.J.5
  • 26
    • 0019733001 scopus 로고
    • Transcutaneous pO2 monitoring for assessing viability and predicting survival of skin flaps: Experimental and clinical correlations
    • D. Serafin, C.B. Lesesne, R.Y. Mullen and N.G. Georgiade, Transcutaneous pO2 monitoring for assessing viability and predicting survival of skin flaps: experimental and clinical correlations, J. Microsurg. 2 (1981), 165-178.
    • (1981) J. Microsurg , vol.2 , pp. 165-178
    • Serafin, D.1    Lesesne, C.B.2    Mullen, R.Y.3    Georgiade, N.G.4
  • 27
    • 0031900329 scopus 로고    scopus 로고
    • G.M. Kind, R.F. Buntic, G.M. Buncke, T.M. Cooper, P.P. Siko and H.J. Bunck, Jr., The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants, Plast. Reconstr. Surg. 101 (1998), 1268-1273.
    • G.M. Kind, R.F. Buntic, G.M. Buncke, T.M. Cooper, P.P. Siko and H.J. Bunck, Jr., The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants, Plast. Reconstr. Surg. 101 (1998), 1268-1273.
  • 28
    • 0001748936 scopus 로고
    • New dyes for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation
    • I.J. Fox, L.G.S. Brooker, D.W. Heseltine, H.E. Essex and E.H. Wood, New dyes for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation, Am. J. Physiol. 187 (1956), 599.
    • (1956) Am. J. Physiol , vol.187 , pp. 599
    • Fox, I.J.1    Brooker, L.G.S.2    Heseltine, D.W.3    Essex, H.E.4    Wood, E.H.5
  • 29
    • 70449329284 scopus 로고
    • Indocyanine green: Physical and physiologic properties
    • I.J. Fox and E.H. Wood, Indocyanine green: physical and physiologic properties, Staff Meetings of the Mayo Clinic 35 (1960), 732-744.
    • (1960) Staff Meetings of the Mayo Clinic , vol.35 , pp. 732-744
    • Fox, I.J.1    Wood, E.H.2
  • 30
    • 0016413391 scopus 로고
    • The handling of indocyanine green by the liver
    • G. Paumgartner, The handling of indocyanine green by the liver, Schweiz. Med. Wochenschr. 105 (1975), 1-30.
    • (1975) Schweiz. Med. Wochenschr , vol.105 , pp. 1-30
    • Paumgartner, G.1
  • 32
    • 0025648619 scopus 로고
    • The dye dilution method for measurement of cardiac output
    • P. Lund-Johansen, The dye dilution method for measurement of cardiac output, Eur. Heart J. 11 (1990), 6-12.
    • (1990) Eur. Heart J , vol.11 , pp. 6-12
    • Lund-Johansen, P.1
  • 33
    • 14944356360 scopus 로고    scopus 로고
    • The role of near-infrared angiography in the assessment of post-operative venous congestion in ran-dom pattern, pedicled island and free flaps
    • G. Krishnan, G. Schackert and R. Steinmeier, The role of near-infrared angiography in the assessment of post-operative venous congestion in ran-dom pattern, pedicled island and free flaps, Br. J. Plast. Surg. 58 (2005), 330-338.
    • (2005) Br. J. Plast. Surg , vol.58 , pp. 330-338
    • Krishnan, G.1    Schackert, G.2    Steinmeier, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.