메뉴 건너뛰기




Volumn 41, Issue 1, 2008, Pages 19-25

Derivation of orthogonal leads from the 12-lead electrocardiogram. Performance of an atrial-based transform for the derivation of P loops

Author keywords

P wave; Vectorcardiography

Indexed keywords

ACCURACY; ARTICLE; CALCULATION; CONTROLLED STUDY; DATA BASE; ELECTROCARDIOGRAPHY; ELECTRODE; EVALUATION RESEARCH; HEART ATRIUM; HUMAN; MAJOR CLINICAL STUDY; P WAVE; PRIORITY JOURNAL;

EID: 38049032336     PISSN: 00220736     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelectrocard.2007.07.003     Document Type: Article
Times cited : (22)

References (16)
  • 2
    • 0347359229 scopus 로고    scopus 로고
    • Atrial flutter vector loops derived from the surface ECG: does the plane of the loop correspond anatomically to the macroreentrant circuit?
    • Ng J., Sahakian A.V., Fisher W.G., and Swiryn S. Atrial flutter vector loops derived from the surface ECG: does the plane of the loop correspond anatomically to the macroreentrant circuit?. J Electrocardiol 36 Suppl (2003) 181
    • (2003) J Electrocardiol , vol.36 , Issue.SUPPL , pp. 181
    • Ng, J.1    Sahakian, A.V.2    Fisher, W.G.3    Swiryn, S.4
  • 3
    • 7544219576 scopus 로고    scopus 로고
    • Surface ECG vector characteristics of organized and disorganized atrial activity during atrial fibrillation
    • Ng J., Sahakian A.V., Fisher W.G., and Swiryn S. Surface ECG vector characteristics of organized and disorganized atrial activity during atrial fibrillation. J Electrocardiol 37 (2004) 91
    • (2004) J Electrocardiol , vol.37 , pp. 91
    • Ng, J.1    Sahakian, A.V.2    Fisher, W.G.3    Swiryn, S.4
  • 4
    • 0014365890 scopus 로고
    • A lead synthesizer for the Frank system to simulate the standard 12-lead electrocardiogram
    • Dower G.E. A lead synthesizer for the Frank system to simulate the standard 12-lead electrocardiogram. J Electrocardiol 1 (1968) 101
    • (1968) J Electrocardiol , vol.1 , pp. 101
    • Dower, G.E.1
  • 5
    • 0019230770 scopus 로고
    • On deriving the electrocardiogram from vectorcardiographic leads
    • Dower G.E., Machado H.B., and Osborne J.A. On deriving the electrocardiogram from vectorcardiographic leads. Clin Cardiol 3 (1980) 87
    • (1980) Clin Cardiol , vol.3 , pp. 87
    • Dower, G.E.1    Machado, H.B.2    Osborne, J.A.3
  • 6
    • 0021345819 scopus 로고
    • The ECGD-a derivation of the ECG from VCG leads
    • Dower G.E. The ECGD-a derivation of the ECG from VCG leads. J Electrocardiol 17 (1984) 189
    • (1984) J Electrocardiol , vol.17 , pp. 189
    • Dower, G.E.1
  • 7
    • 0023305901 scopus 로고
    • Orthogonal electrocardiogram derived from the limb and chest electrodes of the conventional 12-lead system
    • Levkov C.L. Orthogonal electrocardiogram derived from the limb and chest electrodes of the conventional 12-lead system. Med Biol Eng Comput 25 (1987) 155
    • (1987) Med Biol Eng Comput , vol.25 , pp. 155
    • Levkov, C.L.1
  • 8
    • 0026322860 scopus 로고
    • Quantitative assessment of 8 different methods for synthesizing Frank VCGs from simultaneously recorded standard ECG leads
    • Rubel P., Benhadid I., and Fayn J. Quantitative assessment of 8 different methods for synthesizing Frank VCGs from simultaneously recorded standard ECG leads. J Electrocardiol 24 (1992) 197
    • (1992) J Electrocardiol , vol.24 , pp. 197
    • Rubel, P.1    Benhadid, I.2    Fayn, J.3
  • 9
    • 0024261685 scopus 로고
    • Vectorcardiogram synthesized from a 12-lead ECG: superiority of the inverse Dower matrix
    • Edenbrandt L., and Pahlm O. Vectorcardiogram synthesized from a 12-lead ECG: superiority of the inverse Dower matrix. J Electrocardiol 21 (1988) 361
    • (1988) J Electrocardiol , vol.21 , pp. 361
    • Edenbrandt, L.1    Pahlm, O.2
  • 10
    • 24344448716 scopus 로고    scopus 로고
    • Can orthogonal lead indicators of propensity to atrial fibrillation be accurately assessed from the 12-lead ECG?
    • Carlson J., Havmoller R., Herreros A., Platonov P., Johansson R., and Olsson B. Can orthogonal lead indicators of propensity to atrial fibrillation be accurately assessed from the 12-lead ECG?. Europace 7 Suppl 2 (2005) 39
    • (2005) Europace , vol.7 , Issue.SUPPL. 2 , pp. 39
    • Carlson, J.1    Havmoller, R.2    Herreros, A.3    Platonov, P.4    Johansson, R.5    Olsson, B.6
  • 11
    • 38049095457 scopus 로고    scopus 로고
    • The research resource for complex physiologic signals.www.physionet.org. MIT Room (2006) E25-505A.
  • 12
    • 0021892137 scopus 로고
    • A real-time QRS detection algorithm
    • Pan J., and Tompkins W.J. A real-time QRS detection algorithm. IEEE Trans Biomed Eng 32 (1985) 230
    • (1985) IEEE Trans Biomed Eng , vol.32 , pp. 230
    • Pan, J.1    Tompkins, W.J.2
  • 13
    • 0032941256 scopus 로고    scopus 로고
    • Electrocardiogram signal preprocessing for automatic detection of QRS boundaries
    • Daskalov I.K., and Christov I.I. Electrocardiogram signal preprocessing for automatic detection of QRS boundaries. Med Eng Phys 21 (1999) 37
    • (1999) Med Eng Phys , vol.21 , pp. 37
    • Daskalov, I.K.1    Christov, I.I.2
  • 14
    • 38049064327 scopus 로고
    • Comparison of 4 orthogonal systems of vectorcardiography""
    • Langner P.H., Okada R.H., Moore S.R., and Fies H.L. Comparison of 4 orthogonal systems of vectorcardiography"". Circulation 17 (1958) 46
    • (1958) Circulation , vol.17 , pp. 46
    • Langner, P.H.1    Okada, R.H.2    Moore, S.R.3    Fies, H.L.4
  • 15
    • 0017110998 scopus 로고
    • Evaluation of synthesized standard 12-leads and Frank vector leads
    • Wolf H.K., Rautaharju P.M., Unite V.C., and Stewart J. Evaluation of synthesized standard 12-leads and Frank vector leads. Adv Cardiol 16 (1976) 87
    • (1976) Adv Cardiol , vol.16 , pp. 87
    • Wolf, H.K.1    Rautaharju, P.M.2    Unite, V.C.3    Stewart, J.4
  • 16
    • 0025679513 scopus 로고
    • Reconstruction of the Frank vectorcardiogram from standard electrocardiographic leads: diagnostic comparison of different methods
    • Kors J.A., Van Herpen G., Sittig A.C., and Van Bemmel J.H. Reconstruction of the Frank vectorcardiogram from standard electrocardiographic leads: diagnostic comparison of different methods. Eur Heart J 11 (1990) 1083
    • (1990) Eur Heart J , vol.11 , pp. 1083
    • Kors, J.A.1    Van Herpen, G.2    Sittig, A.C.3    Van Bemmel, J.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.