메뉴 건너뛰기




Volumn 59, Issue 2, 2007, Pages 197-204

Implanting a left ventricular pacemaker lead

Author keywords

[No Author keywords available]

Indexed keywords

MUSCLE RELAXANT AGENT;

EID: 37849038945     PISSN: 00194832     EISSN: 00194832     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (4)

References (14)
  • 1
    • 37849016103 scopus 로고    scopus 로고
    • Asirvatham SJ and DL Hayes. Biventricular Device Implantation. Hayes DL, et al. editor(s). Resynchronization and defibrillation for heart failure(139-62): p. a practical approach Oxford: Blackwell/Futura; 2004.
    • Asirvatham SJ and DL Hayes. Biventricular Device Implantation. Hayes DL, et al. editor(s). Resynchronization and defibrillation for heart failure(139-62): p. a practical approach Oxford: Blackwell/Futura; 2004.
  • 2
    • 0036623902 scopus 로고    scopus 로고
    • Cardiac resynchronization therapy in advanced heart failure the multicenter InSync clinical study
    • Gras D, et al. Cardiac resynchronization therapy in advanced heart failure the multicenter InSync clinical study. Eur J Heart Fail 2002;4:311-20.
    • (2002) Eur J Heart Fail , vol.4 , pp. 311-320
    • Gras, D.1
  • 3
    • 20544454974 scopus 로고    scopus 로고
    • Utilization of intracardiac echocardiography to access the coronary sinus for left ventricular lead placement
    • Shalaby AA, Utilization of intracardiac echocardiography to access the coronary sinus for left ventricular lead placement. Pacing Clin Electrophysiol 2005;28:493-99.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 493-499
    • Shalaby, A.A.1
  • 4
    • 30444457021 scopus 로고    scopus 로고
    • Left ventricular pacing lead implantation: Potential utility of multimodal image integration
    • Goitein O, et al. Left ventricular pacing lead implantation: potential utility of multimodal image integration. Heart Rhythm 2006;3:91-99.
    • (2006) Heart Rhythm , vol.3 , pp. 91-99
    • Goitein, O.1
  • 5
    • 20544463130 scopus 로고    scopus 로고
    • Use of preshaped sheath to plan and facilitate cannulation of the coronary sinus for the implantation of cardiac resynchronization therapy devices: Preshaped sheath for implantation of biventricular devices
    • Al-Khadra, AS. Use of preshaped sheath to plan and facilitate cannulation of the coronary sinus for the implantation of cardiac resynchronization therapy devices: preshaped sheath for implantation of biventricular devices. Pacing Clin Electrophysiol 2005;28:489-92.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 489-492
    • Al-Khadra, A.S.1
  • 6
    • 37849030659 scopus 로고    scopus 로고
    • Evidence of electrical conduction within the coronary sinus musculature by non-contact mapping
    • Asirvatham S and Packer DL. Evidence of electrical conduction within the coronary sinus musculature by non-contact mapping. Circulation 1999;100:I.850.
    • (1999) Circulation , vol.100
    • Asirvatham, S.1    Packer, D.L.2
  • 7
    • 37849004042 scopus 로고    scopus 로고
    • Coronary venous drainage of the lateral left ventricle: Implications for biventricular pacing
    • Asirvatham SJ, et al. Coronary venous drainage of the lateral left ventricle: Implications for biventricular pacing. Circulation 2001;104:II.619.
    • (2001) Circulation , vol.104
    • Asirvatham, S.J.1
  • 8
    • 19944432481 scopus 로고    scopus 로고
    • A new endocardial "over-the-wire" or stylet-driven left ventricular lead: First clinical experience
    • Ellery S, et al. A new endocardial "over-the-wire" or stylet-driven left ventricular lead: first clinical experience. Pacing Clin Electrophysiol 2005;28:S31-33.
    • (2005) Pacing Clin Electrophysiol , vol.28
    • Ellery, S.1
  • 9
    • 33645693105 scopus 로고    scopus 로고
    • Anatomy, special features and angiographic assessment of the coronary sinus]
    • Lawo T. [Anatomy, special features and angiographic assessment of the coronary sinus]. Herzschrittmacherther Elektrophysiol 2006;17:I1-I6.
    • (2006) Herzschrittmacherther Elektrophysiol , vol.17
    • Lawo, T.1
  • 10
    • 0037348032 scopus 로고    scopus 로고
    • Clinical advantage of neutral anode positioning feature in recent pacemaker generator
    • Abe H, et al. Clinical advantage of neutral anode positioning feature in recent pacemaker generator. J Uoeh 2003;25:13-22.
    • (2003) J Uoeh , vol.25 , pp. 13-22
    • Abe, H.1
  • 11
    • 15344343993 scopus 로고    scopus 로고
    • Beyond coronary sinus angiography: The value of coronary arteriography and identification of the pericardiophrenic vein during left ventricular lead placement
    • Vaseghi M, et al. Beyond coronary sinus angiography: the value of coronary arteriography and identification of the pericardiophrenic vein during left ventricular lead placement. Pacing Clin Electrophysiol 2005;28:185-90.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 185-190
    • Vaseghi, M.1
  • 12
    • 37849035897 scopus 로고    scopus 로고
    • Atrial pouch and pectinate extension across the tricuspid isthmus (Abstract 76PW/10)
    • Asirvatham SJ, et al. Atrial pouch and pectinate extension across the tricuspid isthmus (Abstract 76PW/10). Europace 2002;3:A78.
    • (2002) Europace , vol.3
    • Asirvatham, S.J.1
  • 13
    • 0037132632 scopus 로고    scopus 로고
    • Hansky B, et al. Coronary vein balloon angioplasty for left ventricular pacemaker lead implantation. J Am Coll Cardiol 2002;40:2144-54.
    • Hansky B, et al. Coronary vein balloon angioplasty for left ventricular pacemaker lead implantation. J Am Coll Cardiol 2002;40:2144-54.
  • 14
    • 37849004041 scopus 로고    scopus 로고
    • Coronary venous drainage of the lateral left ventricle: Implications for biventricular pacing (Abstract 539)
    • Talreia D, et al. Coronary venous drainage of the lateral left ventricle: implications for biventricular pacing (Abstract 539). Pacing and Clinical Electrophysiology PACE 2003;26:S135.
    • (2003) Pacing and Clinical Electrophysiology PACE , vol.26
    • Talreia, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.