Volumn 25, Issue 1, 2003, Pages 13-22

Clinical advantage of neutral anode positioning feature in recent pacemaker generator

Author keywords

Bipolar; Generator; Neutral anode positioning; Pacemaker; Unipolar

Indexed keywords

LEAD;

EID: 0037348032     PISSN: 0387821X     EISSN: None     Source Type: Journal    
DOI: 10.7888/juoeh.25.13     Document Type: Article
Times cited : (2)

References (13)
  • 1
    • 0030709319 scopus 로고    scopus 로고
    • Do permanent pacemakers need an insulative coating? Results of a prospective randomized double-blind study
    • Davies T, Dorian P, Yao J, Hart J & Newman D (1997): Do permanent pacemakers need an insulative coating? Results of a prospective randomized double-blind study. PACE 20: 2394-2397
    • (1997) PACE , vol.20 , pp. 2394-2397
    • Davies, T.1    Dorian, P.2    Yao, J.3    Hart, J.4    Newman, D.5
  • 2
    • 0015304979 scopus 로고
    • Complications and malfunctions of electrical cardiac pacemakers
    • Kosowsky BD & Barr I (1972): Complications and malfunctions of electrical cardiac pacemakers. Progress in Cardiovascular Diseases 14: 501-514
    • (1972) Progress in Cardiovascular Diseases , vol.14 , pp. 501-514
    • Kosowsky, B.D.1    Barr, I.2
  • 3
    • 0016294287 scopus 로고
    • Rhythmic shoulder girdle muscle contractions as a complication in pacemaker treatment
    • Ekbom K, Nillson BY, Edhag O & Olin C (1974): Rhythmic shoulder girdle muscle contractions as a complication in pacemaker treatment. Chest 66: 599-601
    • (1974) Chest , vol.66 , pp. 599-601
    • Ekbom, K.1    Nillson, B.Y.2    Edhag, O.3    Olin, C.4
  • 4
    • 0017671397 scopus 로고
    • Myopotential inhibition of a bipolar pacemaker caused by electrode insulation defect
    • Amikam S, Peleg H, Lemer J & Riss E (1977): Myopotential inhibition of a bipolar pacemaker caused by electrode insulation defect. Br Heart J 39: 1279-1281.
    • (1977) Br Heart J , vol.39 , pp. 1279-1281
    • Amikam, S.1    Peleg, H.2    Lemer, J.3    Riss, E.4
  • 5
    • 0017743911 scopus 로고
    • Inhibition of bipolar demand pacemaker by diaphragmatic myopotential
    • Barold SS, Ong LS, Falkoff MD & Heinle RA (1977): Inhibition of bipolar demand pacemaker by diaphragmatic myopotential. Circulation 56: 679-683
    • (1977) Circulation , vol.56 , pp. 679-683
    • Barold, S.S.1    Ong, L.S.2    Falkoff, M.D.3    Heinle, R.A.4
  • 6
    • 0021216276 scopus 로고
    • The clinical incidence and significance of myopotential sensing with unipolar pacemakers
    • Fetter J, Bobeldyk GL & Engman FJ (1984): The clinical incidence and significance of myopotential sensing with unipolar pacemakers. PACE 7: 871-881
    • (1984) PACE , vol.7 , pp. 871-881
    • Fetter, J.1    Bobeldyk, G.L.2    Engman, F.J.3
  • 7
    • 0021689327 scopus 로고
    • Spontaneous rotation of permanent pacemaker - A cause of muscle stimulation and myopotential inhibition
    • Simonsen E & Jensen BS (1984): Spontaneous rotation of permanent pacemaker - a cause of muscle stimulation and myopotential inhibition. Scand J Thor Cardiovasc Surgery 18: 223-225
    • (1984) Scand J Thor Cardiovasc Surgery , vol.18 , pp. 223-225
    • Simonsen, E.1    Jensen, B.S.2
  • 8
    • 0022159503 scopus 로고
    • Oversensing by single-chamber pacemakers: Mechanisms, diagnosis, and treatment
    • Barold SS, Falkoff MD, Ong LS & Heinle RA (1985): Oversensing by single-chamber pacemakers: mechanisms, diagnosis, and treatment. Cardiol Clin 3: 565-585
    • (1985) Cardiol Clin , vol.3 , pp. 565-585
    • Barold, S.S.1    Falkoff, M.D.2    Ong, L.S.3    Heinle, R.A.4
  • 10
    • 0023270735 scopus 로고
    • Pacemaker inhibition by myopotentials associated with motion and exercise
    • Gialafos J, Maillis A & Kandilas J (1987): Pacemaker inhibition by myopotentials associated with motion and exercise. Eur Hear J 8 (suppl D): 149-154
    • (1987) Eur Hear J , vol.8 , Issue.SUPPL. D , pp. 149-154
    • Gialafos, J.1    Maillis, A.2    Kandilas, J.3
  • 11
    • 0023127808 scopus 로고
    • Muscle noise and interference behavior in pacemakers: A comparative study
    • Irnich W (1987): Muscle noise and interference behavior in pacemakers: a comparative study. PACE 10: 125-132
    • (1987) PACE , vol.10 , pp. 125-132
    • Irnich, W.1
  • 12
    • 0023466125 scopus 로고
    • Muscle stimulation caused by a pacemaker current leakage: The role of the insulation failure of a polyurethane coating
    • Chauvin M & Brechenmacher C (1987): Muscle stimulation caused by a pacemaker current leakage: the role of the insulation failure of a polyurethane coating. J Electrophysiol 1: 326-329
    • (1987) J Electrophysiol , vol.1 , pp. 326-329
    • Chauvin, M.1    Brechenmacher, C.2
  • 13
    • 0024379427 scopus 로고
    • The superfast atrial recharge pulse: A cause of pectoral muscle stimulation in patients equipped with a unipolar DDD pacemaker
    • Stroobandt R, Willems R, Depuydt P, Holvoet G & Sinnaeve A (1989): The superfast atrial recharge pulse: a cause of pectoral muscle stimulation in patients equipped with a unipolar DDD pacemaker. PACE 12: 451-455
    • (1989) PACE , vol.12 , pp. 451-455
    • Stroobandt, R.1    Willems, R.2    Depuydt, P.3    Holvoet, G.4    Sinnaeve, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.