메뉴 건너뛰기




Volumn 76, Issue 2, 2008, Pages 168-174

Sensitivity and specificity of an automated external defibrillator algorithm designed for pediatric patients

Author keywords

Arrhythmias; Automated external defibrillator (AED); Cardiac arrest; Cardiac resuscitation; Electric countershock instrumentation

Indexed keywords

ALGORITHM; ARTICLE; AUTOMATED EXTERNAL DEFIBRILLATOR; CHILD; CONTROLLED STUDY; DEFIBRILLATION; ELECTROCARDIOGRAPHY; EQUIPMENT DESIGN; HEART RHYTHM; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; INFANT; MAJOR CLINICAL STUDY; PEDIATRICS; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SINUS RHYTHM; SUPRAVENTRICULAR TACHYCARDIA;

EID: 37849034409     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2007.06.032     Document Type: Article
Times cited : (53)

References (20)
  • 1
    • 0037126332 scopus 로고    scopus 로고
    • Public use of automated external defibrillators
    • Caffrey S.L., Willoughby P.J., Pepe P.E., and Becker L.B. Public use of automated external defibrillators. NEJM 347 (2002) 1242-1247
    • (2002) NEJM , vol.347 , pp. 1242-1247
    • Caffrey, S.L.1    Willoughby, P.J.2    Pepe, P.E.3    Becker, L.B.4
  • 2
    • 0028284976 scopus 로고
    • Early defibrillation by police: initial experience with the measurement of critical time intervals and patient outcome
    • White R.D., Vukov L.F., and Bugliosi T.F. Early defibrillation by police: initial experience with the measurement of critical time intervals and patient outcome. Ann Emerg Med 23 (1994) 1009-1013
    • (1994) Ann Emerg Med , vol.23 , pp. 1009-1013
    • White, R.D.1    Vukov, L.F.2    Bugliosi, T.F.3
  • 3
    • 22744435310 scopus 로고    scopus 로고
    • Hospital-wide first-responder automated external defibrillator programme: 1 year experience
    • Hanefeld C., Lichte C., Mentges-Schroter I., Sirtl C., and Mugge A. Hospital-wide first-responder automated external defibrillator programme: 1 year experience. Resuscitation 66 2 (2005) 167-170
    • (2005) Resuscitation , vol.66 , Issue.2 , pp. 167-170
    • Hanefeld, C.1    Lichte, C.2    Mentges-Schroter, I.3    Sirtl, C.4    Mugge, A.5
  • 4
    • 0028935212 scopus 로고
    • Out-of-hospital ventricular fibrillation in children and adolescents: causes and outcome
    • Mogayzel C., Quan L., Graves J.R., Tiedeman D., Fahrenbruch C., and Herndon P. Out-of-hospital ventricular fibrillation in children and adolescents: causes and outcome. Ann Emerg Med 25 (1995) 484-491
    • (1995) Ann Emerg Med , vol.25 , pp. 484-491
    • Mogayzel, C.1    Quan, L.2    Graves, J.R.3    Tiedeman, D.4    Fahrenbruch, C.5    Herndon, P.6
  • 6
    • 29944442726 scopus 로고    scopus 로고
    • National registry of cardiopulmonary resuscitation. I First documented rhythm and clinical outcome from in-hospital cardiac arrest among children and adults
    • Nadkarni V.M., Larkin G.L., Peberdy M.A., et al. National registry of cardiopulmonary resuscitation. I First documented rhythm and clinical outcome from in-hospital cardiac arrest among children and adults. JAMA 295 1 (2006) 50-57
    • (2006) JAMA , vol.295 , Issue.1 , pp. 50-57
    • Nadkarni, V.M.1    Larkin, G.L.2    Peberdy, M.A.3
  • 7
    • 33751207748 scopus 로고    scopus 로고
    • A prospective study of outcome of in-patient paediatric cardiopulmonary arrest
    • Tibballs J., and Kinney S. A prospective study of outcome of in-patient paediatric cardiopulmonary arrest. Resuscitation 71 3 (2006) 310-318
    • (2006) Resuscitation , vol.71 , Issue.3 , pp. 310-318
    • Tibballs, J.1    Kinney, S.2
  • 8
    • 0037821556 scopus 로고    scopus 로고
    • Use of automated external defibrillators for children-an update: an advisory statement from the pediatric advanced life support task force, international liaison committee on resuscitation
    • Samson R.A., Berg R.A., Bingham R., et al. Use of automated external defibrillators for children-an update: an advisory statement from the pediatric advanced life support task force, international liaison committee on resuscitation. Circulation 107 (2003) 3250-3255
    • (2003) Circulation , vol.107 , pp. 3250-3255
    • Samson, R.A.1    Berg, R.A.2    Bingham, R.3
  • 9
    • 0035933171 scopus 로고    scopus 로고
    • Is AED arrhythmia detection accurate for children? sensitivity and specificity of an AED algorithm in 696 pediatric arrhythmias
    • Cecchin F.C., Perry J.C., Berul C.I., et al. Is AED arrhythmia detection accurate for children? sensitivity and specificity of an AED algorithm in 696 pediatric arrhythmias. Circulation 103 (2001) 2483-2488
    • (2001) Circulation , vol.103 , pp. 2483-2488
    • Cecchin, F.C.1    Perry, J.C.2    Berul, C.I.3
  • 10
    • 0037859124 scopus 로고    scopus 로고
    • Specificity and sensitivity of automated external defibrillators rhythm analysis in infants and young children
    • Atkinson E., Mikysa B., Conway J.A., et al. Specificity and sensitivity of automated external defibrillators rhythm analysis in infants and young children. Ann Emerg Med 42 (2003) 185-196
    • (2003) Ann Emerg Med , vol.42 , pp. 185-196
    • Atkinson, E.1    Mikysa, B.2    Conway, J.A.3
  • 11
    • 16944364417 scopus 로고    scopus 로고
    • Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms, and enhancing safety
    • Kerber R.E., Becker L.B., Bourland J.D., et al. Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms, and enhancing safety. Circulation 95 (1997) 1677-1682
    • (1997) Circulation , vol.95 , pp. 1677-1682
    • Kerber, R.E.1    Becker, L.B.2    Bourland, J.D.3
  • 12
    • 21544447006 scopus 로고    scopus 로고
    • Attenuated pediatric electrode pads for automated external defibrillator use in children
    • Atkins D.L., and Jorgenson D.B. Attenuated pediatric electrode pads for automated external defibrillator use in children. Resuscitation 66 (2005) 31-37
    • (2005) Resuscitation , vol.66 , pp. 31-37
    • Atkins, D.L.1    Jorgenson, D.B.2
  • 13
    • 0034332799 scopus 로고    scopus 로고
    • Successful use of a biphasic waveform automated external defibrillator in a high-risk child
    • Gurnett C.A., and Atkins D.L. Successful use of a biphasic waveform automated external defibrillator in a high-risk child. Am J Cardiol 86 (2000) 1051-1053
    • (2000) Am J Cardiol , vol.86 , pp. 1051-1053
    • Gurnett, C.A.1    Atkins, D.L.2
  • 14
    • 0036217535 scopus 로고    scopus 로고
    • Energy attenuator for pediatric application of an automated external defibrillator
    • Jorgenson D., Morgan C., Snyder D., et al. Energy attenuator for pediatric application of an automated external defibrillator. Crit Care Med 30 4 Suppl. (2002) S145-S147
    • (2002) Crit Care Med , vol.30 , Issue.4 SUPPL
    • Jorgenson, D.1    Morgan, C.2    Snyder, D.3
  • 15
    • 33646065525 scopus 로고    scopus 로고
    • ECC Committee, Task Forces of the American Heart Association. 2005 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2005; 112 (24 Suppl):13.
  • 17
    • 0032927752 scopus 로고    scopus 로고
    • A prospective, population-based study of the demographics, epidemiology, management, and outcome of out-of-hospital pediatric cardiopulmonary arrest
    • Sirbaugh P.E., Pepe P.E., Shook J.E., et al. A prospective, population-based study of the demographics, epidemiology, management, and outcome of out-of-hospital pediatric cardiopulmonary arrest. Ann Emerg Med 33 (1999) 174-184
    • (1999) Ann Emerg Med , vol.33 , pp. 174-184
    • Sirbaugh, P.E.1    Pepe, P.E.2    Shook, J.E.3
  • 18
    • 27944479076 scopus 로고    scopus 로고
    • Out-of-hospital pediatric cardiac arrest: an epidemiologic review and assessment of current knowledge
    • Donoghue A.J., Nadkarni V., Berg R.A., et al. Out-of-hospital pediatric cardiac arrest: an epidemiologic review and assessment of current knowledge. Ann Emerg Med 46 6 (2005) 512-522
    • (2005) Ann Emerg Med , vol.46 , Issue.6 , pp. 512-522
    • Donoghue, A.J.1    Nadkarni, V.2    Berg, R.A.3
  • 19
    • 0031950605 scopus 로고    scopus 로고
    • Accurate recognition and effective treatment of ventricular fibrillation by automated external defibrillators in adolescents
    • Atkins D.L., Hartley L.L., and York D.K. Accurate recognition and effective treatment of ventricular fibrillation by automated external defibrillators in adolescents. Pediatrics 101 (1998) 393-397
    • (1998) Pediatrics , vol.101 , pp. 393-397
    • Atkins, D.L.1    Hartley, L.L.2    York, D.K.3
  • 20
    • 33745149244 scopus 로고    scopus 로고
    • Feasibility of a study to assess efficacy of defibrillation in children
    • Knilans T.K., Atkins D.L., Berg R.A., Nadkarni V., and Bean J. Feasibility of a study to assess efficacy of defibrillation in children. Circulation 106 (2002) II-403
    • (2002) Circulation , vol.106
    • Knilans, T.K.1    Atkins, D.L.2    Berg, R.A.3    Nadkarni, V.4    Bean, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.