-
1
-
-
0023712327
-
Macroscopic and microscopic evidence of prosthetic fixation with porouscoated materials
-
Collier JP, Mayor MB, Chae JC, et al. (1988) Macroscopic and microscopic evidence of prosthetic fixation with porouscoated materials. Clinical Orthop Relat Res 235: 173-180
-
(1988)
Clinical Orthop Relat Res
, vol.235
, pp. 173-180
-
-
Collier, J.P.1
Mayor, M.B.2
Chae, J.C.3
-
3
-
-
0037331012
-
A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: Clinical, radiographic and survivorship analyses with comparison to the literature
-
Epinette JA, Manley MT, D'Antonio JA, et al. (2003) A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature. J Arthroplasty 2: 140-148
-
(2003)
J Arthroplasty
, vol.2
, pp. 140-148
-
-
Epinette, J.A.1
Manley, M.T.2
D'Antonio, J.A.3
-
4
-
-
0026664139
-
Hydroxyapatite coating of hip prostheses. Effect on migration into the femur
-
Kroon PO, Freeman MA (1992) Hydroxyapatite coating of hip prostheses. Effect on migration into the femur. J Bone Joint Surg Br 74: 518-522
-
(1992)
J Bone Joint Surg Br
, vol.74
, pp. 518-522
-
-
Kroon, P.O.1
Freeman, M.A.2
-
5
-
-
0029057148
-
Clinical outcome and survival of link RS total hip prosthesis
-
Savilahti S, Myllyneva I, Lindholm TS, et al. (1995) Clinical outcome and survival of link RS total hip prosthesis. J Bone Joint Surg Br 77: 369-373
-
(1995)
J Bone Joint Surg Br
, vol.77
, pp. 369-373
-
-
Savilahti, S.1
Myllyneva, I.2
Lindholm, T.S.3
-
6
-
-
0023777583
-
The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
-
Engh CA, Bobyn JD (1988) The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res 231: 7-28
-
(1988)
Clin Orthop Relat Res
, vol.231
, pp. 7-28
-
-
Engh, C.A.1
Bobyn, J.D.2
-
7
-
-
0027397479
-
The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study
-
Heekin RD, Callaghan JJ, Hopkinson WJ, et al. (1993) The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study. J Bone Joint Surg Am 75: 77-91
-
(1993)
J Bone Joint Surg Am
, vol.75
, pp. 77-91
-
-
Heekin, R.D.1
Callaghan, J.J.2
Hopkinson, W.J.3
-
8
-
-
0020559913
-
The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study
-
Lord G, Bancel P (1983) The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study. Clin Orthop Relat Res 176: 67-76
-
(1983)
Clin Orthop Relat Res
, vol.176
, pp. 67-76
-
-
Lord, G.1
Bancel, P.2
-
9
-
-
0030696486
-
Proximally coated ingrowth prostheses. A review
-
Mont MA, Hungerford DS (1997) Proximally coated ingrowth prostheses. A review. Clin Orthop Relat Res 344: 139-149
-
(1997)
Clin Orthop Relat Res
, vol.344
, pp. 139-149
-
-
Mont, M.A.1
Hungerford, D.S.2
-
10
-
-
0027161508
-
Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement
-
Martell JM, Pierson RH 3rd, Jacobs JJ, et al. (1993) Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg Am 75: 554-571
-
(1993)
J Bone Joint Surg Am
, vol.75
, pp. 554-571
-
-
Martell, J.M.1
Pierson III, R.H.2
Jacobs, J.J.3
-
11
-
-
0023778434
-
Development and first experience with an uncemented press-fit cup
-
Morscher E, Masar Z (1988) Development and first experience with an uncemented press-fit cup. Clin Orthop Relat Res 232: 96-103
-
(1988)
Clin Orthop Relat Res
, vol.232
, pp. 96-103
-
-
Morscher, E.1
Masar, Z.2
-
13
-
-
0022975696
-
Tissue reactions to titanium endoprostheses. Autopsy studies in four cases
-
Lintner F, Zweymüller KA, Brand G (1986) Tissue reactions to titanium endoprostheses. Autopsy studies in four cases. J Arthroplasty 3: 183-195
-
(1986)
J Arthroplasty
, vol.3
, pp. 183-195
-
-
Lintner, F.1
Zweymüller, K.A.2
Brand, G.3
-
15
-
-
33845447717
-
Hydroxyapatite-coated femoral components: 15-year minimum follow-up
-
Capello WN, D'Antonio JA, Jaffe WL, et al. (2006) Hydroxyapatite-coated femoral components: 15-year minimum follow-up. Clin Orthop Relat Res 453: 75-80
-
(2006)
Clin Orthop Relat Res
, vol.453
, pp. 75-80
-
-
Capello, W.N.1
D'Antonio, J.A.2
Jaffe, W.L.3
-
16
-
-
0034807973
-
Hydroxyapatite-coated versus grit-blasted femoral stems. A prospective, randomized study using EBRA-FCA
-
Hamadouche M, Witvoet J, Porcher R, et al. (2001) Hydroxyapatite-coated versus grit-blasted femoral stems. A prospective, randomized study using EBRA-FCA. J Bone Joint Surg Br 83: 979-987
-
(2001)
J Bone Joint Surg Br
, vol.83
, pp. 979-987
-
-
Hamadouche, M.1
Witvoet, J.2
Porcher, R.3
-
17
-
-
33646059484
-
Comparison of two hydroxyapatite-coated femoral stems: Clinical, functional and bone densitometry evaluation of patients randomized to a regular or modified hydroxyapatite-coated stem aimed at proximal fixation
-
Sluimer JC, Hoefnagels NH, Emans PJ, et al. (2006) Comparison of two hydroxyapatite-coated femoral stems: clinical, functional and bone densitometry evaluation of patients randomized to a regular or modified hydroxyapatite-coated stem aimed at proximal fixation. J Arthroplasty 21: 344-352
-
(2006)
J Arthroplasty
, vol.21
, pp. 344-352
-
-
Sluimer, J.C.1
Hoefnagels, N.H.2
Emans, P.J.3
-
18
-
-
0025898856
-
Fixation of hip prostheses by hydroxyapatite ceramic coatings
-
Furlong RJ, Osborn JF (1991) Fixation of hip prostheses by hydroxyapatite ceramic coatings. J Bone Joint Surg Br 73: 741-745
-
(1991)
J Bone Joint Surg Br
, vol.73
, pp. 741-745
-
-
Furlong, R.J.1
Osborn, J.F.2
-
19
-
-
0030872929
-
Hydroxyapatite-coated total hip femoral components in patients less than fifty years old. Clinical and radiographic results after five to eight years of follow-up
-
Capello WN, D'Antonio JA, Feinberg JR, Manley MT (1997) Hydroxyapatite-coated total hip femoral components in patients less than fifty years old. Clinical and radiographic results after five to eight years of follow-up. J Bone Joint Surg Am 79: 1023-1029
-
(1997)
J Bone Joint Surg Am
, vol.79
, pp. 1023-1029
-
-
Capello, W.N.1
D'Antonio, J.A.2
Feinberg, J.R.3
Manley, M.T.4
-
20
-
-
2342545438
-
High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for ten years
-
Oosterbos CJ, Rahmy AI, Tonino AJ, Witpeerd W (2004) High survival rate of hydroxyapatite-coated hip prostheses: 100 consecutive hips followed for ten years. Acta Orthop Scand 75: 127-133
-
(2004)
Acta Orthop Scand
, vol.75
, pp. 127-133
-
-
Oosterbos, C.J.1
Rahmy, A.I.2
Tonino, A.J.3
Witpeerd, W.4
-
21
-
-
0033668244
-
Calcium phosphate coatings for fixation of bone implants. Evaluated mechanically and histologically by stereological methods
-
Overgaard S (2000) Calcium phosphate coatings for fixation of bone implants. Evaluated mechanically and histologically by stereological methods. Acta Orthop Scand Suppl 297, Volume 71: 1-71
-
(2000)
Acta Orthop Scand Suppl 297
, vol.71
, pp. 1-71
-
-
Overgaard, S.1
-
22
-
-
9144234772
-
Hydroxyapatite ceramic-coated femoral stems in young patients. A prospective ten-year study
-
Singh S, Trikha SP, Edge AJ (2004) Hydroxyapatite ceramic-coated femoral stems in young patients. A prospective ten-year study. J Bone Joint Surg Br 86: 1118-1123
-
(2004)
J Bone Joint Surg Br
, vol.86
, pp. 1118-1123
-
-
Singh, S.1
Trikha, S.P.2
Edge, A.J.3
-
24
-
-
0035190728
-
Morphometric examination of straight tapered titanium stems: A retrieval study
-
Böhm G, Lintner F, Auterith A, et al. (2001) Morphometric examination of straight tapered titanium stems: a retrieval study. Clinical Orthop Relat Res 393: 13-24
-
(2001)
Clinical Orthop Relat Res
, vol.393
, pp. 13-24
-
-
Böhm, G.1
Lintner, F.2
Auterith, A.3
-
25
-
-
0035034959
-
Sealing effect of hydroxyapatite coating on peri-implant migration of particles. An experimental study in dogs
-
Rahbek O, Overgaard S, Lind M, et al. (2001) Sealing effect of hydroxyapatite coating on peri-implant migration of particles. An experimental study in dogs. J Bone Joint Surg Br 83: 441-447
-
(2001)
J Bone Joint Surg Br
, vol.83
, pp. 441-447
-
-
Rahbek, O.1
Overgaard, S.2
Lind, M.3
-
26
-
-
0032486509
-
Healing of large (2 mm) gaps around calcium phosphate-coated bone implants: A study in goats with a follow-up of 6 months
-
Clemens JA, Klein CP, Vriesde RC, et al. (1998) Healing of large (2 mm) gaps around calcium phosphate-coated bone implants: a study in goats with a follow-up of 6 months. J Biomed Mater Res 40: 341-349
-
(1998)
J Biomed Mater Res
, vol.40
, pp. 341-349
-
-
Clemens, J.A.1
Klein, C.P.2
Vriesde, R.C.3
-
27
-
-
0023499767
-
Chemical implant fixation using hydroxyapatite coatings. the development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates
-
Geesink RG, de Groot GK, Klein CP (1987) Chemical implant fixation using hydroxyapatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop Relat Res 225: 147-170
-
(1987)
Clin Orthop Relat Res
, vol.225
, pp. 147-170
-
-
Geesink, R.G.1
De Groot, G.K.2
Klein, C.P.3
-
28
-
-
0036166445
-
Osteoconductive coatings for total joint arthroplasty
-
Geesink RG (2002) Osteoconductive coatings for total joint arthroplasty. Clin Orthop Relat Res 395: 53-65
-
(2002)
Clin Orthop Relat Res
, vol.395
, pp. 53-65
-
-
Geesink, R.G.1
-
29
-
-
0025082451
-
Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and non-interference fit
-
Søballe K, Brockstedt-Rasmussen H, Pedersen CM, Bünger C (1990) Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and non-interference fit. Acta Orthop Scand 61: 299-306
-
(1990)
Acta Orthop Scand
, vol.61
, pp. 299-306
-
-
Søballe, K.1
Brockstedt-Rasmussen, H.2
Pedersen, C.M.3
Bünger, C.4
-
30
-
-
33846934780
-
Radiolucent lines and osteolysis along tapered straight cementless titanium hip stems: A comparison of 6-year and 10-year follow-up results in 95 patients
-
Zweymüller KA, Schwarzinger UM, Steindl MS (2006) Radiolucent lines and osteolysis along tapered straight cementless titanium hip stems: a comparison of 6-year and 10-year follow-up results in 95 patients. Acta Orthop 77: 871-876
-
(2006)
Acta Orthop
, vol.77
, pp. 871-876
-
-
Zweymüller, K.A.1
Schwarzinger, U.M.2
Steindl, M.S.3
-
31
-
-
0036512931
-
Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: A minimum ten-year follow-up
-
Grübl A, Chiari C, Gruber M, et al. (2002) Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg Am 84: 425-431
-
(2002)
J Bone Joint Surg Am
, vol.84
, pp. 425-431
-
-
Grübl, A.1
Chiari, C.2
Gruber, M.3
-
32
-
-
0038304521
-
Long-term results with the cementless Alloclassic brand hip arthroplasty system
-
Pieringer H, Auersperg V, Griessler W, Böhler N (2003) Long-term results with the cementless Alloclassic brand hip arthroplasty system. J Arthroplasty 18: 321-328
-
(2003)
J Arthroplasty
, vol.18
, pp. 321-328
-
-
Pieringer, H.1
Auersperg, V.2
Griessler, W.3
Böhler, N.4
-
33
-
-
25844503781
-
Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years
-
Pospischill M, Knahr K (2005) Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years. J Bone Joint Surg Br 87: 1210-1215
-
(2005)
J Bone Joint Surg Br
, vol.87
, pp. 1210-1215
-
-
Pospischill, M.1
Knahr, K.2
-
35
-
-
0032466986
-
Non cemented hip replacement using a conical screw-in cup and a straight press-fit stem. A six to eight-year clinical and radiological follow-up study
-
4
-
Köster G, Leib S, Willert HG (1998) Non cemented hip replacement using a conical screw-in cup and a straight press-fit stem. A six to eight-year clinical and radiological follow-up study. Hip International 8(4): 208-218
-
(1998)
Hip International
, vol.8
, pp. 208-218
-
-
Köster, G.1
Leib, S.2
Willert, H.G.3
-
37
-
-
0029796988
-
Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral component. Justification for continuance of use
-
Mallory TH, Head WC, Lombardi AV Jr., et al. (1996) Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral component. Justification for continuance of use. J Arthroplasty 11: 653-660
-
(1996)
J Arthroplasty
, vol.11
, pp. 653-660
-
-
Mallory, T.H.1
Head, W.C.2
Lombardi Jr., A.V.3
-
38
-
-
0031725839
-
Total hip arthroplasty with porous-coated prostheses fixed without cement in patients who are 65 years of age or older
-
McAuley JP, Moore KD, Culpepper WJ 2nd, Engh CA (1998) Total hip arthroplasty with porous-coated prostheses fixed without cement in patients who are 65 years of age or older. J Bone Joint Surg Am 80: 1648-1655
-
(1998)
J Bone Joint Surg Am
, vol.80
, pp. 1648-1655
-
-
Moore, K.D.1
Culpepper II, W.J.2
Engh, C.A.3
-
39
-
-
0030039643
-
Early radiographic results comparing cemented and cementless total hip arthroplasty
-
Mulliken BD, Nayak N, Bourne RB, et al (1996) Early radiographic results comparing cemented and cementless total hip arthroplasty. J Arthroplasty 11: 24-33
-
(1996)
J Arthroplasty
, vol.11
, pp. 24-33
-
-
Mulliken, B.D.1
Nayak, N.2
Bourne, R.B.3
-
40
-
-
0042671122
-
Cementless total hip arthroplasty in patients older than 80 years of age
-
Pieringer H, Labek G, Auersperg V, Böhler N (2003) Cementless total hip arthroplasty in patients older than 80 years of age. J Bone Joint Surg Br 85: 641-645
-
(2003)
J Bone Joint Surg Br
, vol.85
, pp. 641-645
-
-
Pieringer, H.1
Labek, G.2
Auersperg, V.3
Böhler, N.4
-
42
-
-
33845410092
-
Hydroxyapatite-coated titanium porous plasma spray tapered stem: Experience at 15 to 18 years
-
Lombardi AV Jr., Berend KR, Mallory TH (2006) Hydroxyapatite-coated titanium porous plasma spray tapered stem: experience at 15 to 18 years. Clin Orthop Relat Res 453: 81-85
-
(2006)
Clin Orthop Relat Res
, vol.453
, pp. 81-85
-
-
Lombardi Jr., A.V.1
Berend, K.R.2
Mallory, T.H.3
-
43
-
-
0031714773
-
Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation
-
Dorr LD, Wan Z, Song M, Ranawat A (1998) Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation. J Arthroplasty 13: 729-736
-
(1998)
J Arthroplasty
, vol.13
, pp. 729-736
-
-
Dorr, L.D.1
Wan, Z.2
Song, M.3
Ranawat, A.4
-
44
-
-
0038779677
-
Comparison of hydroxyapatite and porous-coated stems in total hip replacement
-
Park YS, Lee JY, Yun SH, et al. (2003) Comparison of hydroxyapatite and porous-coated stems in total hip replacement. Acta Orthop Scand 74: 259-263
-
(2003)
Acta Orthop Scand
, vol.74
, pp. 259-263
-
-
Park, Y.S.1
Lee, J.Y.2
Yun, S.H.3
-
45
-
-
33744988576
-
Tapered hydroxyapatite-coated press-fit stems: Any added value?
-
Rorabeck CH (2006) Tapered hydroxyapatite-coated press-fit stems: any added value? J Arthroplasty 21: 85-88
-
(2006)
J Arthroplasty
, vol.21
, pp. 85-88
-
-
Rorabeck, C.H.1
-
46
-
-
0029874286
-
Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants
-
Rothman RH, Hozack WJ, Ranawat A, Moriarty L (1996) Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants. J Bone Joint Surg Am 78: 319-324
-
(1996)
J Bone Joint Surg Am
, vol.78
, pp. 319-324
-
-
Rothman, R.H.1
Hozack, W.J.2
Ranawat, A.3
Moriarty, L.4
-
47
-
-
33846500279
-
Hydroxyapatite porous coating and the osteointegration of the total hip replacement
-
Landor I, Vavrik P, Sosna A, et al. (2007) Hydroxyapatite porous coating and the osteointegration of the total hip replacement. Arch Orthop Trauma Surg 127: 81-89
-
(2007)
Arch Orthop Trauma Surg
, vol.127
, pp. 81-89
-
-
Landor, I.1
Vavrik, P.2
Sosna, A.3
-
48
-
-
0036175102
-
Hydroxyapatite coating improves 8-to 10-year performance of the link RS cementless femoral stem
-
Palm L, Jacobsson SA, Ivarsson I (2002) Hydroxyapatite coating improves 8-to 10-year performance of the link RS cementless femoral stem. J Arthroplasty 17: 172-175
-
(2002)
J Arthroplasty
, vol.17
, pp. 172-175
-
-
Palm, L.1
Jacobsson, S.A.2
Ivarsson, I.3
-
49
-
-
3042517840
-
High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses: 65 hips in 56 young patients followed for 5-9 years
-
Blacha J (2004) High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses: 65 hips in 56 young patients followed for 5-9 years. Acta Orthop Scand 75: 276-282
-
(2004)
Acta Orthop Scand
, vol.75
, pp. 276-282
-
-
Blacha, J.1
-
50
-
-
0345490858
-
Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem
-
Tonino AJ, Thèrin M, Doyle C (1999) Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem. J Bone Joint Surg Br 81: 148-154
-
(1999)
J Bone Joint Surg Br
, vol.81
, pp. 148-154
-
-
Tonino, A.J.1
Thèrin, M.2
Doyle, C.3
|