메뉴 건너뛰기




Volumn 21, Issue 3, 2006, Pages 344-352

Comparison of Two Hydroxyapatite-Coated Femoral Stems. Clinical, Functional, and Bone Densitometry Evaluation of Patients Randomized to a Regular or Modified Hydroxyapatite-Coated Stem Aimed at Proximal Fixation

Author keywords

BMD; DEXA; hydroxyapatite; pain; proximal fixation

Indexed keywords

HYDROXYAPATITE;

EID: 33646059484     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2005.06.015     Document Type: Article
Times cited : (29)

References (23)
  • 1
    • 0036166445 scopus 로고    scopus 로고
    • Osteoconductive coatings for total joint arthroplasty
    • Geesink R.G.T. Osteoconductive coatings for total joint arthroplasty. Clin Orthop 395 (2002) 53
    • (2002) Clin Orthop , vol.395 , pp. 53
    • Geesink, R.G.T.1
  • 2
    • 0035190630 scopus 로고    scopus 로고
    • Hydroxyapatite femoral stems for total hip arthroplasty: 10- to 13-year followup
    • D'Antonio J.A., Capello W.N., Manley M.T., et al. Hydroxyapatite femoral stems for total hip arthroplasty: 10- to 13-year followup. Clin Orthop 393 (2001) 101
    • (2001) Clin Orthop , vol.393 , pp. 101
    • D'Antonio, J.A.1    Capello, W.N.2    Manley, M.T.3
  • 3
    • 0034113275 scopus 로고    scopus 로고
    • The results at nine to twelve years of the use of a hydroxyapatite-coated femoral stem
    • McNally S.A., Shepperd J.A., Mann C.V., et al. The results at nine to twelve years of the use of a hydroxyapatite-coated femoral stem. J Bone Joint Surg Br 82 (2000) 378
    • (2000) J Bone Joint Surg Br , vol.82 , pp. 378
    • McNally, S.A.1    Shepperd, J.A.2    Mann, C.V.3
  • 4
    • 0035051334 scopus 로고    scopus 로고
    • Hydroxyapatite coated hip prosthesis followed up for 5 years
    • Oosterbos C.J., Rahmy A.I., and Tonino A.J. Hydroxyapatite coated hip prosthesis followed up for 5 years. Int Orthop 25 (2001) 17
    • (2001) Int Orthop , vol.25 , pp. 17
    • Oosterbos, C.J.1    Rahmy, A.I.2    Tonino, A.J.3
  • 5
    • 0026519501 scopus 로고
    • Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty
    • Bobyn J.D., Mortimer E.S., Glassman A.H., et al. Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop (1992) 79
    • (1992) Clin Orthop , pp. 79
    • Bobyn, J.D.1    Mortimer, E.S.2    Glassman, A.H.3
  • 6
    • 0031425681 scopus 로고    scopus 로고
    • Eight years results of HA-coated primary total hip replacement
    • Geesink R., and Hoefnagels N. Eight years results of HA-coated primary total hip replacement. Acta Orthop Belg 63 Suppl 1 (1997) 72
    • (1997) Acta Orthop Belg , vol.63 , Issue.SUPPL. 1 , pp. 72
    • Geesink, R.1    Hoefnagels, N.2
  • 7
    • 0031694210 scopus 로고    scopus 로고
    • Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years
    • Manley M.T., Capello W.N., D'Antonio J.A., et al. Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years. J Bone Joint Surg Am 80 (1998) 1175
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1175
    • Manley, M.T.1    Capello, W.N.2    D'Antonio, J.A.3
  • 8
    • 0001441434 scopus 로고
    • Bone destruction not demonstrable by radiography
    • Ardran G.M. Bone destruction not demonstrable by radiography. Br J Radiol 24 (1951) 107
    • (1951) Br J Radiol , vol.24 , pp. 107
    • Ardran, G.M.1
  • 9
    • 0025784682 scopus 로고
    • The initiation of failure in cemented femoral components of hip arthroplasties
    • Jasty M., Maloney W.J., Bragdon C.R., et al. The initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg Br 73 (1991) 551
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 551
    • Jasty, M.1    Maloney, W.J.2    Bragdon, C.R.3
  • 10
    • 0033384217 scopus 로고    scopus 로고
    • Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling
    • Rosenthall L., Bobyn J.D., and Tanzer M. Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling. Int Orthop 23 (1999) 325
    • (1999) Int Orthop , vol.23 , pp. 325
    • Rosenthall, L.1    Bobyn, J.D.2    Tanzer, M.3
  • 11
    • 0029978595 scopus 로고    scopus 로고
    • Host-bone response to porous-coated cobalt-chrome and hydroxyapatite-coated titanium femoral components in hip arthroplasty. Dual-energy x-ray absorptiometry analysis of paired bilateral cases at 5 to 7 years
    • Scott D.F., and Jaffe W.L. Host-bone response to porous-coated cobalt-chrome and hydroxyapatite-coated titanium femoral components in hip arthroplasty. Dual-energy x-ray absorptiometry analysis of paired bilateral cases at 5 to 7 years. J Arthroplasty 11 (1996) 429
    • (1996) J Arthroplasty , vol.11 , pp. 429
    • Scott, D.F.1    Jaffe, W.L.2
  • 12
    • 0027230459 scopus 로고
    • Structural and cellular assessment of bone quality of proximal femur
    • Dorr L.D., Faugere M.C., Mackel A.M., et al. Structural and cellular assessment of bone quality of proximal femur. Bone 14 (1993) 231
    • (1993) Bone , vol.14 , pp. 231
    • Dorr, L.D.1    Faugere, M.C.2    Mackel, A.M.3
  • 13
    • 0015295233 scopus 로고
    • The long-term results of low-friction arthroplasty of the hip performed as a primary intervention
    • Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br 54 (1972) 61
    • (1972) J Bone Joint Surg Br , vol.54 , pp. 61
    • Charnley, J.1
  • 14
    • 0015692144 scopus 로고
    • Factors influencing the results in 2,012 total hip arthroplasties
    • Ilstrup D.M., Nolan D.R., Beckenbaugh R.D., et al. Factors influencing the results in 2,012 total hip arthroplasties. Clin Orthop 95 (1973) 250
    • (1973) Clin Orthop , vol.95 , pp. 250
    • Ilstrup, D.M.1    Nolan, D.R.2    Beckenbaugh, R.D.3
  • 15
    • 77049159486 scopus 로고
    • Functional results of hip arthroplasty with acrylic prosthesis
    • D'Aubigne R.M., and Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 36-A (1954) 451
    • (1954) J Bone Joint Surg Am , vol.36 -A , pp. 451
    • D'Aubigne, R.M.1    Postel, M.2
  • 16
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening
    • Gruen T.A., McNeice G.M., and Amstutz H.C. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop (1979) 17
    • (1979) Clin Orthop , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 17
    • 0023240947 scopus 로고
    • Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results
    • Engh C.A., Bobyn J.D., and Glassman A.H. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69 (1987) 45
    • (1987) J Bone Joint Surg Br , vol.69 , pp. 45
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 18
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • Engh C.A., and Bobyn J.D. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop (1988) 7
    • (1988) Clin Orthop , pp. 7
    • Engh, C.A.1    Bobyn, J.D.2
  • 19
    • 0029310680 scopus 로고
    • Is stem length important in uncemented endoprostheses?
    • Tanner K.E., Yettram A.L., Loeffler M., et al. Is stem length important in uncemented endoprostheses?. Med Eng Phys 17 (1995) 291
    • (1995) Med Eng Phys , vol.17 , pp. 291
    • Tanner, K.E.1    Yettram, A.L.2    Loeffler, M.3
  • 20
    • 0028822681 scopus 로고
    • Preclinical testing of total hip stems. The effects of coating placement
    • Huiskes R., and van Rietbergen B. Preclinical testing of total hip stems. The effects of coating placement. Clin Orthop (1995) 64
    • (1995) Clin Orthop , pp. 64
    • Huiskes, R.1    van Rietbergen, B.2
  • 21
    • 0033950612 scopus 로고    scopus 로고
    • Influence of porous coating level on proximal femoral remodeling. A postmortem analysis
    • McAuley J.P., Sychterz C.J., and Engh Sr. C.A. Influence of porous coating level on proximal femoral remodeling. A postmortem analysis. Clin Orthop (2000) 146
    • (2000) Clin Orthop , pp. 146
    • McAuley, J.P.1    Sychterz, C.J.2    Engh Sr., C.A.3
  • 22
    • 0033808993 scopus 로고    scopus 로고
    • The effect of partial vs. full hydroxyapatite coating on periprosthetic bone quality around the canine madreporic femoral stem
    • Al Hertani W., Waddell J.P., and Anderson G.I. The effect of partial vs. full hydroxyapatite coating on periprosthetic bone quality around the canine madreporic femoral stem. J Biomed Mater Res 53 (2000) 518
    • (2000) J Biomed Mater Res , vol.53 , pp. 518
    • Al Hertani, W.1    Waddell, J.P.2    Anderson, G.I.3
  • 23
    • 0036150880 scopus 로고    scopus 로고
    • Measurement of periprosthetic bone mineral density by dual-energy x-ray absorptiometry is useful for estimating fixation between the bone and the prosthesis in an early stage
    • Okano T., Hagino H., Otsuka T., et al. Measurement of periprosthetic bone mineral density by dual-energy x-ray absorptiometry is useful for estimating fixation between the bone and the prosthesis in an early stage. J Arthroplasty 17 (2002) 49
    • (2002) J Arthroplasty , vol.17 , pp. 49
    • Okano, T.1    Hagino, H.2    Otsuka, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.