메뉴 건너뛰기




Volumn 73, Issue 2, 2008, Pages 200-206

Randomized controlled study of biocompatible peritoneal dialysis solutions: Effect on residual renal function

Author keywords

Creatinine clearance; End stage renal failure; Peritoneal dialysis; Peritoneal membrane; Randomized controlled trials

Indexed keywords

CREATININE; UREA;

EID: 37549066703     PISSN: 00852538     EISSN: 15231755     Source Type: Journal    
DOI: 10.1038/sj.ki.5002574     Document Type: Article
Times cited : (142)

References (20)
  • 1
    • 0036242468 scopus 로고
    • Morphological and functional changes in the dialysed peritoneal cavity: Impact of more biocompatible solutions
    • Devuyst O, Topley N, Williams JD. Morphological and functional changes in the dialysed peritoneal cavity: impact of more biocompatible solutions. Nephrol Dial Transplant 1907; 17(Suppl 3): 12-15.
    • (1907) Nephrol Dial Transplant , vol.17 , Issue.SUPPL. 3 , pp. 12-15
    • Devuyst, O.1    Topley, N.2    Williams, J.D.3
  • 2
    • 0035126591 scopus 로고    scopus 로고
    • Effects of bicarbonate/lactate solution on peritoneal advanced glycosylation end-product accumulation
    • Park MS, Kim JK, Holmes C, Weiss MF. Effects of bicarbonate/lactate solution on peritoneal advanced glycosylation end-product accumulation. Perit Dial Int 2000; 20(Suppl 5): S33-S38.
    • (2000) Perit Dial Int , vol.20 , Issue.SUPPL. 5
    • Park, M.S.1    Kim, J.K.2    Holmes, C.3    Weiss, M.F.4
  • 3
    • 0035126233 scopus 로고    scopus 로고
    • Effects of conventional and new peritoneal dialysis solutions on human peritoneal mesothelial cell viability and proliferation
    • Ha H, Yu MR, Choi HN et al. Effects of conventional and new peritoneal dialysis solutions on human peritoneal mesothelial cell viability and proliferation. Perit Dial Int 2000; 20(Suppl 5): S10-S18.
    • (2000) Perit Dial Int , vol.20 , Issue.SUPPL. 5
    • Ha, H.1    Yu, M.R.2    Choi, H.N.3
  • 4
    • 4544300340 scopus 로고    scopus 로고
    • The triggering of human peritoneal mesothelial cell apoptosis and oncosis by glucose and glycoxydation products
    • Boulanger E, Wautier MP, Gane P et al. The triggering of human peritoneal mesothelial cell apoptosis and oncosis by glucose and glycoxydation products. Nephrol Dial Transplant 2004; 19: 2208-2216.
    • (2004) Nephrol Dial Transplant , vol.19 , pp. 2208-2216
    • Boulanger, E.1    Wautier, M.P.2    Gane, P.3
  • 5
    • 0345305343 scopus 로고    scopus 로고
    • The in vitro biocompatibility performance of a 25 mmol/l bicarbonate/10 mmol/l lactate-buffered peritoneal dialysis fluid
    • Skoufos L, Topley N, Cooker L et al. The in vitro biocompatibility performance of a 25 mmol/l bicarbonate/10 mmol/l lactate-buffered peritoneal dialysis fluid. Kidney Int Suppl 2003; 88: S94-S99.
    • (2003) Kidney Int Suppl , vol.88
    • Skoufos, L.1    Topley, N.2    Cooker, L.3
  • 6
    • 0030668276 scopus 로고    scopus 로고
    • Effect of two-chambered bicarbonate lactate-buffered peritoneal dialysis fluids on peripheral blood mononuclear cell and polymorphonuclear cell function in vitro
    • Sundaram S, Cendoroglo M, Cooker LA et al. Effect of two-chambered bicarbonate lactate-buffered peritoneal dialysis fluids on peripheral blood mononuclear cell and polymorphonuclear cell function in vitro. Am J Kidney Dis 1997; 30: 680-689.
    • (1997) Am J Kidney Dis , vol.30 , pp. 680-689
    • Sundaram, S.1    Cendoroglo, M.2    Cooker, L.A.3
  • 7
    • 33749611755 scopus 로고    scopus 로고
    • Changing prescribing practice in CAPD patients in Korea: Increased utilization of low GDP solutions improves patient outcome
    • Lee HY, Choi HY, Park HC et al. Changing prescribing practice in CAPD patients in Korea: increased utilization of low GDP solutions improves patient outcome. Nephrol Dial Transplant 2006; 21: 2893-2899.
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 2893-2899
    • Lee, H.Y.1    Choi, H.Y.2    Park, H.C.3
  • 8
    • 21144438457 scopus 로고    scopus 로고
    • Superior patient survival for continuous ambulatory peritoneal dialysis patients treated with a peritoneal dialysis fluid with neutral pH and low glucose degradation product concentration (Balance)
    • Lee HY, Park HC, Seo BJ et al. Superior patient survival for continuous ambulatory peritoneal dialysis patients treated with a peritoneal dialysis fluid with neutral pH and low glucose degradation product concentration (Balance). Perit Dial Int 2005; 25: 248-255.
    • (2005) Perit Dial Int , vol.25 , pp. 248-255
    • Lee, H.Y.1    Park, H.C.2    Seo, B.J.3
  • 9
    • 0034823268 scopus 로고    scopus 로고
    • Relative contribution of residual renal function and peritoneal clearance to adequacy of dialysis: A reanalysis of the CANUSA study
    • Bargman JM, Thorpe KE, Churchill DN. Relative contribution of residual renal function and peritoneal clearance to adequacy of dialysis: a reanalysis of the CANUSA study. J Am Soc Nephrol 2001; 12: 2158-2162.
    • (2001) J Am Soc Nephrol , vol.12 , pp. 2158-2162
    • Bargman, J.M.1    Thorpe, K.E.2    Churchill, D.N.3
  • 10
    • 3042720430 scopus 로고    scopus 로고
    • On behalf of The Euro-Balance Trial. The Euro-Balance Trial: The effect of a new biocompatible peritoneal dialysis fluid (balance) on the peritoneal membrane
    • Williams JD, Topley N, Craig KJ, et al., On behalf of The Euro-Balance Trial. The Euro-Balance Trial: the effect of a new biocompatible peritoneal dialysis fluid (balance) on the peritoneal membrane. Kidney Int 2004; 66: 408-418.
    • (2004) Kidney Int , vol.66 , pp. 408-418
    • Williams, J.D.1    Topley, N.2    Craig, K.J.3
  • 11
    • 33749633151 scopus 로고    scopus 로고
    • Peritoneal dialysis solutions and patient survival: Does wishing make it so?
    • Bargman JM. Peritoneal dialysis solutions and patient survival: does wishing make it so? Nephrol Dial Transplant 2006; 21: 2684-2686.
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 2684-2686
    • Bargman, J.M.1
  • 12
    • 34447534546 scopus 로고    scopus 로고
    • Single UK centre experience on the treatment of PD peritonitis - antibiotic levels and outcomes
    • Blunden M, Zeitlin D, Ashman N, Fan SL. Single UK centre experience on the treatment of PD peritonitis - antibiotic levels and outcomes. Nephrol Dial Transplant 2007; 22: 1714-1719.
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 1714-1719
    • Blunden, M.1    Zeitlin, D.2    Ashman, N.3    Fan, S.L.4
  • 13
    • 33846654231 scopus 로고    scopus 로고
    • Clinical biocompatibility of a neutral peritoneal dialysis solution with minimal glucose-degradation products - a 1-year randomized control trial
    • Szeto CC, Chow KM, Lam CW et al. Clinical biocompatibility of a neutral peritoneal dialysis solution with minimal glucose-degradation products - a 1-year randomized control trial. Nephrol Dial Transplant 2007; 22: 552-559.
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 552-559
    • Szeto, C.C.1    Chow, K.M.2    Lam, C.W.3
  • 14
    • 0037354544 scopus 로고    scopus 로고
    • C-reactive protein and anti-Chlamydia pneumoniae antibodies as risk factors of cardiovascular death in incident patients on peritoneal dialysis
    • Paniagua R, Frias Y, de Ventura MJ et al. C-reactive protein and anti-Chlamydia pneumoniae antibodies as risk factors of cardiovascular death in incident patients on peritoneal dialysis. Perit Dial Int 2003; 23: 132-137.
    • (2003) Perit Dial Int , vol.23 , pp. 132-137
    • Paniagua, R.1    Frias, Y.2    de Ventura, M.J.3
  • 15
    • 34447296693 scopus 로고    scopus 로고
    • Anti-inflammatory effects of 3-hydroxy-3-methylglutaryl coenzyme a reductase inhibitors (statins) in peritoneal dialysis patients
    • Kumar S, Raftery M, Yaqoob M, Fan SL. Anti-inflammatory effects of 3-hydroxy-3-methylglutaryl coenzyme a reductase inhibitors (statins) in peritoneal dialysis patients. Perit Dial Int 2007; 27: 283-287.
    • (2007) Perit Dial Int , vol.27 , pp. 283-287
    • Kumar, S.1    Raftery, M.2    Yaqoob, M.3    Fan, S.L.4
  • 16
    • 0344011072 scopus 로고    scopus 로고
    • Clinical indices of in vivo biocompatibility: The role of ex vivo cell function studies and effluent markers in peritoneal dialysis patients
    • Mackenzie R, Holmes CJ, Jones S et al. Clinical indices of in vivo biocompatibility: the role of ex vivo cell function studies and effluent markers in peritoneal dialysis patients. Kidney Int Suppl 2003; 88: S84-S93.
    • (2003) Kidney Int Suppl , vol.88
    • Mackenzie, R.1    Holmes, C.J.2    Jones, S.3
  • 17
    • 0031786152 scopus 로고    scopus 로고
    • Biocompatibility and buffers: Effect of bicarbonate-buffered peritoneal dialysis fluids on peritoneal cell function
    • Jorres A, Bender TO, Finn A et al. Biocompatibility and buffers: effect of bicarbonate-buffered peritoneal dialysis fluids on peritoneal cell function. Kidney Int 1998; 54: 2184-2193.
    • (1998) Kidney Int , vol.54 , pp. 2184-2193
    • Jorres, A.1    Bender, T.O.2    Finn, A.3
  • 18
    • 0035162741 scopus 로고    scopus 로고
    • Long-term clinical effects of a peritoneal dialysis fluid with less glucose degradation products
    • Rippe B, Simonsen O, Heimburger O et al. Long-term clinical effects of a peritoneal dialysis fluid with less glucose degradation products. Kidney Int 2001; 59: 348-357.
    • (2001) Kidney Int , vol.59 , pp. 348-357
    • Rippe, B.1    Simonsen, O.2    Heimburger, O.3
  • 19
    • 0030330059 scopus 로고    scopus 로고
    • Less infusion pain and elevated level of cancer antigen 125 by the use of a new and more biocompatible PD fluid
    • Simonsen O, Wieslander A, Landgren C, Rippe B. Less infusion pain and elevated level of cancer antigen 125 by the use of a new and more biocompatible PD fluid. Adv Perit Dial 1996; 12: 156-160.
    • (1996) Adv Perit Dial , vol.12 , pp. 156-160
    • Simonsen, O.1    Wieslander, A.2    Landgren, C.3    Rippe, B.4
  • 20
    • 0141790160 scopus 로고    scopus 로고
    • Improved acidosis correction and recovery of mesothelial cell mass with neutral-pH bicarbonate dialysis solution among children undergoing automated peritoneal dialysis
    • Haas S, Schmitt CP, Arbeiter K et al. Improved acidosis correction and recovery of mesothelial cell mass with neutral-pH bicarbonate dialysis solution among children undergoing automated peritoneal dialysis. J Am Soc Nephrol 2003; 14: 2632-2638.
    • (2003) J Am Soc Nephrol , vol.14 , pp. 2632-2638
    • Haas, S.1    Schmitt, C.P.2    Arbeiter, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.