메뉴 건너뛰기




Volumn 43, Issue 5, 2008, Pages 861-870

Carbon monoxide transport in an enclosed room with sources from a water heater in the adjacent balcony

Author keywords

Carbon monoxide; Poisoning; Transport; Water heater

Indexed keywords

AIR; CARBON MONOXIDE; FLOW FIELDS; FLOW OF GASES; FLOW RATE; HOUSES; TRANSPORT PROPERTIES; VENTILATION; WATER HEATERS;

EID: 37549045686     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2007.01.023     Document Type: Article
Times cited : (12)

References (17)
  • 1
    • 37549035336 scopus 로고    scopus 로고
    • Li WY, Hsu SG. Management of the manufacture and storage of high-pressure combustible gas. NFA report. 2002 [in Chinese].
  • 2
    • 0020913604 scopus 로고    scopus 로고
    • Broyd TW, Dean RB, Olfeld SG, Moult A. The use of computational method to assess the safety and quality of ventilation in industrial buildings. In: Proceedings of the Institute of Mechanical Engineers conference, heat and fluid Flow in nuclear and process plant safety. London, 17-18 May 1983.
  • 3
    • 37549031222 scopus 로고    scopus 로고
    • Murakami S. New scales for ventilation efficiency and their application based on numerical simulation of room airflow. In: Proceeding of international symposium on room air convection and ventilation effectiveness, University of Tokyo, 1992. p.2-38.
  • 4
    • 37549044970 scopus 로고    scopus 로고
    • Liddament MW. The role and application of ventilation effectiveness in design. In: Proceeding of international symposium on room air convection and ventilation effectiveness, University of Tokyo, 1992. p.59-75.
  • 5
    • 0034127261 scopus 로고    scopus 로고
    • Modeling of heat and carbon monoxide emitted from moving cars in an underground car park
    • Xue H., and Ho J.C. Modeling of heat and carbon monoxide emitted from moving cars in an underground car park. Tunnel and Underground Space Technology 15 (2000) 101-115
    • (2000) Tunnel and Underground Space Technology , vol.15 , pp. 101-115
    • Xue, H.1    Ho, J.C.2
  • 6
    • 0038035885 scopus 로고    scopus 로고
    • Air quality in an underground garage: computational and experimental investigation of ventilation effectiveness
    • Papakonstantinoua K., Chaloulakoua A., Ducia A., Vlachakisb N., and Markatosa N. Air quality in an underground garage: computational and experimental investigation of ventilation effectiveness. Energy and Buildings 35 (2003) 933-940
    • (2003) Energy and Buildings , vol.35 , pp. 933-940
    • Papakonstantinoua, K.1    Chaloulakoua, A.2    Ducia, A.3    Vlachakisb, N.4    Markatosa, N.5
  • 7
    • 17644428041 scopus 로고    scopus 로고
    • Numerical approach of carbon monoxide concentration dispersion in an enclosed garage
    • Duci A., Papakonstantinou K., Chaloulakou A., and Markatos N. Numerical approach of carbon monoxide concentration dispersion in an enclosed garage. Building and Environment 39 (2004) 1043-1048
    • (2004) Building and Environment , vol.39 , pp. 1043-1048
    • Duci, A.1    Papakonstantinou, K.2    Chaloulakou, A.3    Markatos, N.4
  • 8
    • 0242337697 scopus 로고    scopus 로고
    • Field study on determination of carbon monoxide level and thermal environment in an underground car park
    • Hoa J.C., Xueb H., and Tay K.L. Field study on determination of carbon monoxide level and thermal environment in an underground car park. Building and Environment 39 (2004) 67-75
    • (2004) Building and Environment , vol.39 , pp. 67-75
    • Hoa, J.C.1    Xueb, H.2    Tay, K.L.3
  • 9
    • 1642372613 scopus 로고    scopus 로고
    • Car park ventilation system: performance evaluation
    • Chan M.Y., and Chow W.K. Car park ventilation system: performance evaluation. Building and Environment 39 (2004) 635-643
    • (2004) Building and Environment , vol.39 , pp. 635-643
    • Chan, M.Y.1    Chow, W.K.2
  • 10
    • 0029949953 scopus 로고    scopus 로고
    • CO concentration inside the cross harbor tunnel in Hong Kong
    • Chan L.Y., Zeng L., Qin Y., and Lee S.C. CO concentration inside the cross harbor tunnel in Hong Kong. Environment International 22 (1996) 405-409
    • (1996) Environment International , vol.22 , pp. 405-409
    • Chan, L.Y.1    Zeng, L.2    Qin, Y.3    Lee, S.C.4
  • 11
    • 0035261715 scopus 로고    scopus 로고
    • Tunnel study of on-road vehicle emissions and the photochemical potential in Taiwan
    • Hsua Y.C., Tsaia J.H., Chena H.W., and Lin W.Y. Tunnel study of on-road vehicle emissions and the photochemical potential in Taiwan. Chemosphere 42 (2001) 227-234
    • (2001) Chemosphere , vol.42 , pp. 227-234
    • Hsua, Y.C.1    Tsaia, J.H.2    Chena, H.W.3    Lin, W.Y.4
  • 12
    • 0036007097 scopus 로고    scopus 로고
    • Carbon monoxide levels measured in major commuting corridors covering different land use and road way microenvironments in Hong Kong
    • Chan Y., Liu Y.M., Lee S.C., and Chan C.Y. Carbon monoxide levels measured in major commuting corridors covering different land use and road way microenvironments in Hong Kong. Atmospheric Environment 36 (2002) 255-264
    • (2002) Atmospheric Environment , vol.36 , pp. 255-264
    • Chan, Y.1    Liu, Y.M.2    Lee, S.C.3    Chan, C.Y.4
  • 13
    • 0038682427 scopus 로고    scopus 로고
    • Air velocity and concentration of noxious substances in a naturally ventilated tunnel
    • Modic J. Air velocity and concentration of noxious substances in a naturally ventilated tunnel. Tunneling and Underground Space Technology 18 (2003) 405-410
    • (2003) Tunneling and Underground Space Technology , vol.18 , pp. 405-410
    • Modic, J.1
  • 15
    • 0000860697 scopus 로고
    • A calculation procedure for heat, mass and momentum transfer in parabolic flows
    • Patankar S.V., and Spalding D.B. A calculation procedure for heat, mass and momentum transfer in parabolic flows. International Journal of Heat and Mass Transfer 21 (1972) 1565-1579
    • (1972) International Journal of Heat and Mass Transfer , vol.21 , pp. 1565-1579
    • Patankar, S.V.1    Spalding, D.B.2
  • 17
    • 0036472863 scopus 로고    scopus 로고
    • Measurement of interstitial convective heat transfer and frictional drag for flow across metal foams
    • Hwang J.J., Hwang G.J., Yeh R.H., and Chao C.H. Measurement of interstitial convective heat transfer and frictional drag for flow across metal foams. Journal of Heat Transfer 124 (2002) 120-129
    • (2002) Journal of Heat Transfer , vol.124 , pp. 120-129
    • Hwang, J.J.1    Hwang, G.J.2    Yeh, R.H.3    Chao, C.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.