-
3
-
-
0042903710
-
A general scheme for constructing inversion algorithms for cone beam CT
-
10.1155/S0161171203209315 0161-1712
-
Katsevich A 2003 A general scheme for constructing inversion algorithms for cone beam CT Int. J. Math. Math. Sci. 21 1305-21
-
(2003)
Int. J. Math. Math. Sci.
, vol.2003
, Issue.21
, pp. 1305-1321
-
-
Katsevich, A.1
-
6
-
-
0141520674
-
A quasiexact reconstruction algorithm for helical CT using a 3-pi acquisition
-
10.1118/1.1601913 0094-2405
-
Bontus C, Kohler T and Proksa R 2003 A quasiexact reconstruction algorithm for helical CT using a 3-pi acquisition Med. Phys. 30 2493-502
-
(2003)
Med. Phys.
, vol.30
, Issue.9
, pp. 2493-2502
-
-
Bontus, C.1
Kohler, T.2
Proksa, R.3
-
8
-
-
18744393588
-
-
http://www.imp.uni-erlangen.de/phantoms/thorax/thorax.htm
-
-
-
-
9
-
-
0036665224
-
Theoretically exact filtered backprojection-type inversion algorithm for spiral CT
-
10.1137/S0036139901387186 0036-1399
-
Katsevich A 2002 Theoretically exact filtered backprojection-type inversion algorithm for spiral CT SIAM J. Appl. Math. 62 2012-26
-
(2002)
SIAM J. Appl. Math.
, vol.62
, Issue.6
, pp. 2012-2026
-
-
Katsevich, A.1
-
10
-
-
0346752328
-
Exact helical reconstruction using native cone-beam geometries
-
0031-9155 001
-
Noo F, Pack J D and Heuscher D 2003 Exact helical reconstruction using native cone-beam geometries Phys. Med. Biol. 48 3787-818
-
(2003)
Phys. Med. Biol.
, vol.48
, Issue.23
, pp. 3787-3818
-
-
Noo, F.1
Pack, J.D.2
Heuscher, D.3
-
11
-
-
9744276664
-
Image reconstruction for the circle and line trajectory
-
0031-9155 003
-
Katsevich A 2004 Image reconstruction for the circle and line trajectory Phys. Med. Biol. 49 5059-72
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.22
, pp. 5059-5072
-
-
Katsevich, A.1
-
12
-
-
0020764170
-
An inversion formula for cone-beam reconstruction
-
10.1137/0143035 0036-1399
-
Tuy H K 1983 An inversion formula for cone-beam reconstruction SIAM J. Appl. Math. 43 546-52
-
(1983)
SIAM J. Appl. Math.
, vol.43
, Issue.3
, pp. 546-552
-
-
Tuy, H.K.1
-
13
-
-
0002018761
-
Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform
-
Grangeat P 1992 Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform Lecture Notes Math. 1497 66
-
(1992)
Lecture Notes Math.
, vol.1497
, pp. 66
-
-
Grangeat, P.1
-
14
-
-
4544351987
-
A two-step Hilbert transform method for 2D image reconstruction
-
0031-9155 006
-
Noo F, Clackdoyle R and Pack J D 2004 A two-step Hilbert transform method for 2D image reconstruction Phys. Med. Biol. 49 3903-23
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.17
, pp. 3903-3923
-
-
Noo, F.1
Clackdoyle, R.2
Pack, J.D.3
-
15
-
-
11844249976
-
Cone-beam reconstruction using the backprojection of locally-filtered projections
-
10.1109/TMI.2004.837794 0278-0062
-
Pack J D, Noo F and Clackdoyle R 2005 Cone-beam reconstruction using the backprojection of locally-filtered projections IEEE Trans. Med. Imaging 24 70-85
-
(2005)
IEEE Trans. Med. Imaging
, vol.24
, Issue.1
, pp. 70-85
-
-
Pack, J.D.1
Noo, F.2
Clackdoyle, R.3
-
16
-
-
1642569142
-
Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT
-
0031-9155 006
-
Zou Y and Pan X 2004 Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT Phys. Med. Biol. 49 941-59
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.6
, pp. 941-959
-
-
Zou, Y.1
Pan, X.2
-
17
-
-
3242756880
-
Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT
-
0031-9155 017
-
Zou Y and Pan X 2004 Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT Phys. Med. Biol. 49 2717-31
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.12
, pp. 2717-2731
-
-
Zou, Y.1
Pan, X.2
-
18
-
-
9744278198
-
An extended data function and its generalized backprojection for image reconstruction in helical cone-beam CT
-
0031-9155 N02
-
Zou Y and Pan X 2004 An extended data function and its generalized backprojection for image reconstruction in helical cone-beam CT Phys. Med. Biol. 49 N383-7
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.22
-
-
Zou, Y.1
Pan, X.2
-
19
-
-
12844256312
-
Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve
-
10.1118/1.1828673 0094-2405
-
Ye Y and Wang G 2005 Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve Med. Phys. 32 42-8
-
(2005)
Med. Phys.
, vol.32
, Issue.1
, pp. 42-48
-
-
Ye, Y.1
Wang, G.2
-
20
-
-
1642277731
-
Minimum detection windows, PI-line existence and uniqueness for helical cone-beam scanning of variable pitch
-
10.1118/1.1646041 0094-2405
-
Ye Y, Zhu J and Wang G 2004 Minimum detection windows, PI-line existence and uniqueness for helical cone-beam scanning of variable pitch Med. Phys. 31 566-72
-
(2004)
Med. Phys.
, vol.31
, Issue.3
, pp. 566-572
-
-
Ye, Y.1
Zhu, J.2
Wang, G.3
-
21
-
-
3042685402
-
Geometric studies on variable radius spiral cone-beam scanning
-
10.1118/1.1751251 0094-2405
-
Ye Y, Zhu J and Wang G 2004 Geometric studies on variable radius spiral cone-beam scanning Med. Phys. 31 1473-80
-
(2004)
Med. Phys.
, vol.31
, Issue.6
, pp. 1473-1480
-
-
Ye, Y.1
Zhu, J.2
Wang, G.3
-
22
-
-
3042738315
-
Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry
-
0031-9155 014
-
Pack J D, Noo F and Kudo H 2004 Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry Phys. Med. Biol. 49 2317-36
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.11
, pp. 2317-2336
-
-
Pack, J.D.1
Noo, F.2
Kudo, H.3
-
23
-
-
0031961518
-
Exact cone-beam CT with a spiral scan
-
0031-9155 028
-
Tam K C, Samarasekera S and Sauer F 1998 Exact cone-beam CT with a spiral scan Phys. Med. Biol. 43 1015-24
-
(1998)
Phys. Med. Biol.
, vol.43
, Issue.4
, pp. 1015-1024
-
-
Tam, K.C.1
Samarasekera, S.2
Sauer, F.3
|