메뉴 건너뛰기




Volumn 16, Issue 4, 2007, Pages 404-412

Failing factors associated with osseointegrated dental implant loss

Author keywords

Dental implant failure; Host features; Osseointegration; Risk factors

Indexed keywords

ARTICLE; DENTAL SURGERY; EDENTULOUSNESS; FEMALE; HUMAN; MALE; MIDDLE AGED; MOUTH DISEASE; RETROSPECTIVE STUDY; STATISTICS; SURVIVAL; TOOTH IMPLANTATION; WEIGHT BEARING;

EID: 37349122069     PISSN: 10566163     EISSN: None     Source Type: Journal    
DOI: 10.1097/ID.0b013e31815c8d31     Document Type: Article
Times cited : (82)

References (73)
  • 1
    • 0141840670 scopus 로고    scopus 로고
    • Implant therapy to improve quality of life
    • Att W, Stappert C. Implant therapy to improve quality of life. Quintessence Int. 2003;34:8:573-581.
    • (2003) Quintessence Int , vol.34 , Issue.8 , pp. 573-581
    • Att, W.1    Stappert, C.2
  • 2
    • 14644436299 scopus 로고    scopus 로고
    • Oral implant restoration for enhanced oral function
    • Henry PJ. Oral implant restoration for enhanced oral function. Clin Exp Pharmacol Physiol. 2005;32:123-127.
    • (2005) Clin Exp Pharmacol Physiol , vol.32 , pp. 123-127
    • Henry, P.J.1
  • 3
    • 0022209866 scopus 로고
    • Surgical principles of the Branemark osseointegration implant system
    • Smith GC. Surgical principles of the Branemark osseointegration implant system. Aust Prosthodont Soc Bull. 1985;15:37-40.
    • (1985) Aust Prosthodont Soc Bull , vol.15 , pp. 37-40
    • Smith, G.C.1
  • 4
    • 11444270659 scopus 로고    scopus 로고
    • Early dental implant failure: A review of the literature
    • Santos MC, Campos MI, Line SR. Early dental implant failure: A review of the literature. Braz J Oral Sci. 2002;1:103-111.
    • (2002) Braz J Oral Sci , vol.1 , pp. 103-111
    • Santos, M.C.1    Campos, M.I.2    Line, S.R.3
  • 5
    • 0026583903 scopus 로고
    • Implantology - 1992: Still more questions than answers
    • Laskin DM. Implantology - 1992: Still more questions than answers. J Oral Maxillofac Surg. 1992;50:109.
    • (1992) J Oral Maxillofac Surg , vol.50 , pp. 109
    • Laskin, D.M.1
  • 6
    • 16644370045 scopus 로고    scopus 로고
    • Biomaterials, biomechanics, tissue healing, and immediatefunction dental implants
    • Lemons JE. Biomaterials, biomechanics, tissue healing, and immediatefunction dental implants. J Oral Implantol. 2004;30:5:318-324.
    • (2004) J Oral Implantol , vol.30 , Issue.5 , pp. 318-324
    • Lemons, J.E.1
  • 8
    • 14944378572 scopus 로고    scopus 로고
    • Treatment of midfacial defects using prostheses supported by ITI dental implants
    • Scolozzi P, Jaques B. Treatment of midfacial defects using prostheses supported by ITI dental implants. Plast Reconstr Surg. 2004;114:1395-1404.
    • (2004) Plast Reconstr Surg , vol.114 , pp. 1395-1404
    • Scolozzi, P.1    Jaques, B.2
  • 9
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Branemark implant in partially edentulous jaws: A 10-year prospective multicenter study
    • Lekholm U, Gunne J, Henry P, et al. Survival of the Branemark implant in partially edentulous jaws: A 10-year prospective multicenter study. Int J Oral Maxillofac Implants. 1999;14:639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3
  • 10
    • 0025583364 scopus 로고
    • Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws
    • Adell R, Eriksson B, Lekholm U, et al. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants. 1990;5:347-359.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 347-359
    • Adell, R.1    Eriksson, B.2    Lekholm, U.3
  • 11
    • 0027792944 scopus 로고
    • The association between the failure of dental implants and cigarette smoking
    • Bain CA, Moy PK. The association between the failure of dental implants and cigarette smoking. Int J Oral Maxillofac Implants. 1993;8:609-615.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 609-615
    • Bain, C.A.1    Moy, P.K.2
  • 12
    • 0030277222 scopus 로고    scopus 로고
    • Smoking and implant failure-Benefits of a smoking cessation protocol
    • Bain CA. Smoking and implant failure-Benefits of a smoking cessation protocol. Int J Oral Maxillofac Implants. 1996;11:756-759.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 756-759
    • Bain, C.A.1
  • 13
    • 14844351376 scopus 로고    scopus 로고
    • Success and failure rates of osseointegrated implants in function in regenerated bone for 72 to 133 months
    • Fugazzotto PA. Success and failure rates of osseointegrated implants in function in regenerated bone for 72 to 133 months. Int J Oral Maxillofac Implants. 2005;20:77-83.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 77-83
    • Fugazzotto, P.A.1
  • 14
    • 0032153519 scopus 로고    scopus 로고
    • Microbial colonization of the peri-implant environment and its relevance to long-term success of osseointegrated implants
    • Ellen RP. Microbial colonization of the peri-implant environment and its relevance to long-term success of osseointegrated implants. Int J Prosthodont. 1998;11:433-441.
    • (1998) Int J Prosthodont , vol.11 , pp. 433-441
    • Ellen, R.P.1
  • 15
    • 12244292727 scopus 로고    scopus 로고
    • Comparison of implant survival following sinus floor augmentation procedures with implants placed in pristine posterior maxillary bone: A systematic review
    • Graziani F, Donos N, Needleman I, et al. Comparison of implant survival following sinus floor augmentation procedures with implants placed in pristine posterior maxillary bone: A systematic review. Clin Oral Implants Res. 2004;15:677-682.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 677-682
    • Graziani, F.1    Donos, N.2    Needleman, I.3
  • 17
    • 0141609012 scopus 로고    scopus 로고
    • Genetic polymorphisms of the interleukin-1 gene and early marginal bone loss around endosseous dental implants
    • Shimpuku H, Nosaka Y, Kawamura T, et al. Genetic polymorphisms of the interleukin-1 gene and early marginal bone loss around endosseous dental implants. Clin Oral Implants Res. 2003;14:423-429.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 423-429
    • Shimpuku, H.1    Nosaka, Y.2    Kawamura, T.3
  • 18
    • 0037264870 scopus 로고    scopus 로고
    • Interventions for replacing missing teeth: Different times for loading dental implants
    • CD003878
    • Esposito M, Worthington HV, Thomsen P, et al. Interventions for replacing missing teeth: Different times for loading dental implants. Cochrane Database Syst Rev. 2004;3:CD003878.
    • (2004) Cochrane Database Syst Rev , pp. 3
    • Esposito, M.1    Worthington, H.V.2    Thomsen, P.3
  • 19
    • 0033161184 scopus 로고    scopus 로고
    • Differential diagnosis and treatment strategies for biologic complications and failing oral implants: A review of the literature
    • Esposito M, Hirsch J, Lekholm U, et al. Differential diagnosis and treatment strategies for biologic complications and failing oral implants: A review of the literature. Int J Oral Maxillofac Implants. 1999;14:473-490.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 473-490
    • Esposito, M.1    Hirsch, J.2    Lekholm, U.3
  • 20
    • 0034157357 scopus 로고    scopus 로고
    • Time dependent failure rate and marginal bone loss of implant supported prostheses: A 15-year follow-up study
    • Snauwaert K, Duyck J, van Steenberghe D, et al. Time dependent failure rate and marginal bone loss of implant supported prostheses: A 15-year follow-up study. Clin Oral Investig. 2000;4:13-20.
    • (2000) Clin Oral Investig , vol.4 , pp. 13-20
    • Snauwaert, K.1    Duyck, J.2    van Steenberghe, D.3
  • 21
    • 0022726532 scopus 로고
    • The long-term efficacy of currently used dental implants: A review and proposed criteria of success
    • Albrektsson T, Zarb G, Worthington P, et al. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986;1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3
  • 22
    • 0024760224 scopus 로고
    • Criteria for success of osseointegrated endosseous implants
    • Smith DE, Zarb GA. Criteria for success of osseointegrated endosseous implants. J Prosthet Dent. 1989;62:567-572.
    • (1989) J Prosthet Dent , vol.62 , pp. 567-572
    • Smith, D.E.1    Zarb, G.A.2
  • 23
    • 29244488214 scopus 로고    scopus 로고
    • Success or failure of dental implants? A literature review with treatment considerations
    • quiz 433, 446
    • Porter JA, von Fraunhofer JA. Success or failure of dental implants? A literature review with treatment considerations. Gen Dent. 2005;53:423-432; quiz 433, 446.
    • (2005) Gen Dent , vol.53 , pp. 423-432
    • Porter, J.A.1    von Fraunhofer, J.A.2
  • 24
    • 0019129440 scopus 로고
    • A photoelastic study of some biomechanical factors affecting the anchorage of osseointegrated implants in the jaw
    • Haraldson T. A photoelastic study of some biomechanical factors affecting the anchorage of osseointegrated implants in the jaw. Scand J Plast Reconstr Surg. 1980;14:209-214.
    • (1980) Scand J Plast Reconstr Surg , vol.14 , pp. 209-214
    • Haraldson, T.1
  • 26
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson T, Branemark PI, Hansson HA, et al. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155-170.
    • (1981) Acta Orthop Scand , vol.52 , pp. 155-170
    • Albrektsson, T.1    Branemark, P.I.2    Hansson, H.A.3
  • 27
    • 0020807637 scopus 로고
    • Direct bone anchorage of dental implants
    • Albrektsson T. Direct bone anchorage of dental implants. J Prosthet Dent. 1983;50:255-261.
    • (1983) J Prosthet Dent , vol.50 , pp. 255-261
    • Albrektsson, T.1
  • 29
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit
    • Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50:101-107.
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Eriksson, A.R.1    Albrektsson, T.2
  • 30
    • 0021685213 scopus 로고
    • The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamber
    • Eriksson RA, Albrektsson T. The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamber. J Oral Maxillofac Surg. 1984;42:705-711.
    • (1984) J Oral Maxillofac Surg , vol.42 , pp. 705-711
    • Eriksson, R.A.1    Albrektsson, T.2
  • 31
    • 0030276810 scopus 로고    scopus 로고
    • Detection and measurement of inflammatory cytokines in implant crevicular fluid: A pilot study
    • Panagakos FS, Aboyoussef H, Dondero R, et al. Detection and measurement of inflammatory cytokines in implant crevicular fluid: A pilot study. Int J Oral Maxillofac Implants. 1996;11:794-799.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 794-799
    • Panagakos, F.S.1    Aboyoussef, H.2    Dondero, R.3
  • 32
    • 0032088918 scopus 로고    scopus 로고
    • Biological factors contributing to failures of osseointegrated oral implants. II. Etiopathogenesis
    • Esposito M, Hirsch JM, Lekholm U, et al. Biological factors contributing to failures of osseointegrated oral implants. II. Etiopathogenesis. Eur J Oral Sci. 1998;106:721-764.
    • (1998) Eur J Oral Sci , vol.106 , pp. 721-764
    • Esposito, M.1    Hirsch, J.M.2    Lekholm, U.3
  • 33
    • 0029396731 scopus 로고
    • Increased interleukin-1 beta in the crevicular fluid of diseased implants
    • Kao RT, Curtis DA, Richards DW, et al. Increased interleukin-1 beta in the crevicular fluid of diseased implants. Int J Oral Maxillofac Implants. 1995;10:696-701.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 696-701
    • Kao, R.T.1    Curtis, D.A.2    Richards, D.W.3
  • 34
    • 37349060161 scopus 로고    scopus 로고
    • Levantamento estatístico do sucesso e causas de insucesso nos trabalhos com implantes osseointegrados do sistema TF publicados no Brasil: Estudo multicêntrico
    • Scaglioni MG, Deliga AG. Levantamento estatístico do sucesso e causas de insucesso nos trabalhos com implantes osseointegrados do sistema TF publicados no Brasil: estudo multicêntrico. BCI. 1996;3:71-76.
    • (1996) BCI , vol.3 , pp. 71-76
    • Scaglioni, M.G.1    Deliga, A.G.2
  • 35
    • 37349057233 scopus 로고    scopus 로고
    • Desenvolvimento de um torquímetro de previsão para o estudo do desempenho de implantes osseointegrados
    • Bianchi CE, de Aguiar PR, Santos MC. Desenvolvimento de um torquímetro de previsão para o estudo do desempenho de implantes osseointegrados. Rev Esc Minas. 2003;56:107-112.
    • (2003) Rev Esc Minas , vol.56 , pp. 107-112
    • Bianchi, C.E.1    de Aguiar, P.R.2    Santos, M.C.3
  • 36
    • 0026135210 scopus 로고
    • Protease activities in peri-implant sulcus fluid from patients with permucosal osseointegrated dental implants. Correlation with clinical parameters
    • Eley BM, Cox SW, Watson RM. Protease activities in peri-implant sulcus fluid from patients with permucosal osseointegrated dental implants. Correlation with clinical parameters. Clin Oral Implants Res. 1991;2:62-70.
    • (1991) Clin Oral Implants Res , vol.2 , pp. 62-70
    • Eley, B.M.1    Cox, S.W.2    Watson, R.M.3
  • 38
    • 37349058034 scopus 로고    scopus 로고
    • Renouard F, Rangert B. Risk Factor in Implant Dentistry: Simplified Clinical Analysis for Predictable Treatment. Carol Stream: Quintessence; 1999:176.
    • Renouard F, Rangert B. Risk Factor in Implant Dentistry: Simplified Clinical Analysis for Predictable Treatment. Carol Stream: Quintessence; 1999:176.
  • 40
    • 17844398780 scopus 로고    scopus 로고
    • The role of implant surface modifications, shape and material on the success of osseointegrated dental implants. A Cochrane systematic review
    • Esposito M, Coulthard P, Thomsen P, et al. The role of implant surface modifications, shape and material on the success of osseointegrated dental implants. A Cochrane systematic review. Eur J Prosthodont Restor Dent. 2005;13:15-31.
    • (2005) Eur J Prosthodont Restor Dent , vol.13 , pp. 15-31
    • Esposito, M.1    Coulthard, P.2    Thomsen, P.3
  • 41
    • 0031989768 scopus 로고    scopus 로고
    • Biological factors contributing to failures of osseointegrated oral implants. I. Success criteria and epidemiology
    • Esposito M, Hirsch JM, Lekholm U, et al. Biological factors contributing to failures of osseointegrated oral implants. I. Success criteria and epidemiology. Eur J Oral Sci. 1998;106:527-551.
    • (1998) Eur J Oral Sci , vol.106 , pp. 527-551
    • Esposito, M.1    Hirsch, J.M.2    Lekholm, U.3
  • 43
    • 0027614095 scopus 로고
    • On statistics of success and loss for dental implants
    • Mau J. On statistics of success and loss for dental implants. Int Dent J. 1993;43:254-261.
    • (1993) Int Dent J , vol.43 , pp. 254-261
    • Mau, J.1
  • 44
    • 0032173716 scopus 로고    scopus 로고
    • Implants: Success and failure - A literature review
    • Koutsonikos A. Implants: Success and failure - A literature review. Ann R Australas Coll Dent Surg. 1998;14:75-80.
    • (1998) Ann R Australas Coll Dent Surg , vol.14 , pp. 75-80
    • Koutsonikos, A.1
  • 45
    • 0037491291 scopus 로고    scopus 로고
    • Clinical and histologic aspects of dental implants removed due to mobility
    • Piattelli A, Scarano A, Favero L, et al. Clinical and histologic aspects of dental implants removed due to mobility. J Periodontol. 2003;74:385-390.
    • (2003) J Periodontol , vol.74 , pp. 385-390
    • Piattelli, A.1    Scarano, A.2    Favero, L.3
  • 46
    • 0027868042 scopus 로고
    • HA-coated implants: Warranted or not?
    • quiz S565-S536
    • Lozada JL, James RA, Boskovic M. HA-coated implants: Warranted or not? Compend Suppl. 1993;15:S539-543; quiz S565-S536.
    • (1993) Compend Suppl , vol.15
    • Lozada, J.L.1    James, R.A.2    Boskovic, M.3
  • 47
    • 0029261651 scopus 로고
    • Registration of localization, occlusion and occluding materials for failing screw joints in the Branemark implant system
    • Wie H. Registration of localization, occlusion and occluding materials for failing screw joints in the Branemark implant system. Clin Oral Implants Res. 1995;6:47-53.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 47-53
    • Wie, H.1
  • 48
    • 13644281863 scopus 로고    scopus 로고
    • Bone collected with a bone collector during dental implant surgery Mikrobiologische Analyse]
    • Kuttenberger JJ, Hardt N, Rutz T, et al. [Bone collected with a bone collector during dental implant surgery Mikrobiologische Analyse]. Mund Kiefer Gesichtschir. 2005;9:18-23.
    • (2005) Mund Kiefer Gesichtschir , vol.9 , pp. 18-23
    • Kuttenberger, J.J.1    Hardt, N.2    Rutz, T.3
  • 49
    • 0032052118 scopus 로고    scopus 로고
    • A histologic evaluation of eight cases of failed dental implants: Is bone overheating the most probable cause?
    • Piattelli A, Piattelli M, Mangano C, et al. A histologic evaluation of eight cases of failed dental implants: Is bone overheating the most probable cause? Biomaterials. 1998;19:683-690.
    • (1998) Biomaterials , vol.19 , pp. 683-690
    • Piattelli, A.1    Piattelli, M.2    Mangano, C.3
  • 50
    • 0024636614 scopus 로고
    • Microbiota and cervicular fluid collagenase activity in the osseointegrated dental implant sulcus: A comparison of sites in edentulous and partially edentulous patients
    • Apse P, Ellen RP, Overall CM, et al. Microbiota and cervicular fluid collagenase activity in the osseointegrated dental implant sulcus: A comparison of sites in edentulous and partially edentulous patients. J Periodontol Res. 1989;24:96-105.
    • (1989) J Periodontol Res , vol.24 , pp. 96-105
    • Apse, P.1    Ellen, R.P.2    Overall, C.M.3
  • 51
    • 0025412014 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part I: Surgical results
    • Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part I: Surgical results. J Prosthet Dent. 1990;63:451-457.
    • (1990) J Prosthet Dent , vol.63 , pp. 451-457
    • Zarb, G.A.1    Schmitt, A.2
  • 52
    • 11444260171 scopus 로고    scopus 로고
    • A comparison of characteristics of implant failure and survival in periodontally compromised and periodontally healthy patients: A clinical report
    • Rosenberg ES, Cho SC, Elian N, et al. A comparison of characteristics of implant failure and survival in periodontally compromised and periodontally healthy patients: A clinical report. Int J Oral Maxillofac Implants. 2004;19:873-879.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 873-879
    • Rosenberg, E.S.1    Cho, S.C.2    Elian, N.3
  • 53
    • 0035489399 scopus 로고    scopus 로고
    • A retrospective analysis of factors associated with multiple implant failures in maxillae
    • Ekfeldt A, Christiansson U, Eriksson T, et al. A retrospective analysis of factors associated with multiple implant failures in maxillae. Clin Oral Implants Res. 2001;12:462-467.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 462-467
    • Ekfeldt, A.1    Christiansson, U.2    Eriksson, T.3
  • 54
    • 0025516555 scopus 로고
    • The implant/tissue interface in a clinical perspective]
    • van Steenberghe D, Quirynen M. [The implant/tissue interface in a clinical perspective]. Parodontol. 1990;1:343-350.
    • (1990) Parodontol , vol.1 , pp. 343-350
    • van Steenberghe, D.1    Quirynen, M.2
  • 55
    • 12244313461 scopus 로고    scopus 로고
    • Consensus statements and recommended clinical procedures regarding implant survival and complications
    • Lang NP, Berglundh T, Heitz-Mayfield LJ, et al. Consensus statements and recommended clinical procedures regarding implant survival and complications. Int J Oral Maxillofac Implants. 2004;19(suppl):150-154.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , Issue.SUPPL. , pp. 150-154
    • Lang, N.P.1    Berglundh, T.2    Heitz-Mayfield, L.J.3
  • 56
    • 0035290284 scopus 로고    scopus 로고
    • Early implant failures in patients treated with Branemark system titanium dental implants: A retrospective study
    • Kronstrom M, Svenson B, Hellman M, et al. Early implant failures in patients treated with Branemark system titanium dental implants: A retrospective study. Int J Oral Maxillofac Implants. 2001;16:201-207.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 201-207
    • Kronstrom, M.1    Svenson, B.2    Hellman, M.3
  • 57
    • 0242522165 scopus 로고    scopus 로고
    • Bone quantity and quality: Are they relevant predictors of implant outcomes?
    • discussion 47-51
    • Stanford CM. Bone quantity and quality: Are they relevant predictors of implant outcomes? Int J Prosthodont. 2003;16(suppl):43-45; discussion 47-51.
    • (2003) Int J Prosthodont , vol.16 , Issue.SUPPL. , pp. 43-45
    • Stanford, C.M.1
  • 58
    • 16844384221 scopus 로고    scopus 로고
    • 7-year follow-up of 93 immediately loaded titanium dental implants
    • Degidi M, Piattelli A. 7-year follow-up of 93 immediately loaded titanium dental implants. J Oral Implantol. 2005;31:25-31.
    • (2005) J Oral Implantol , vol.31 , pp. 25-31
    • Degidi, M.1    Piattelli, A.2
  • 59
    • 0026429873 scopus 로고
    • Osseointegration and the edentulous predicament. The 10-year-old Toronto study
    • Zarb GA, Schmitt A. Osseointegration and the edentulous predicament. The 10-year-old Toronto study. Br Dent J. 1991;170:439-444.
    • (1991) Br Dent J , vol.170 , pp. 439-444
    • Zarb, G.A.1    Schmitt, A.2
  • 60
    • 0027015903 scopus 로고
    • A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects
    • Naert I, Quirynen M, van Steenberghe D, et al. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects. J Prosthet Dent. 1992;68:949-956.
    • (1992) J Prosthet Dent , vol.68 , pp. 949-956
    • Naert, I.1    Quirynen, M.2    van Steenberghe, D.3
  • 61
    • 0032150708 scopus 로고    scopus 로고
    • Surgical determinants of clinical success of osseointegrated oral implants: A review of the literature
    • Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants: A review of the literature. Int J Prosthodont. 1998;11:408-420.
    • (1998) Int J Prosthodont , vol.11 , pp. 408-420
    • Sennerby, L.1    Roos, J.2
  • 62
    • 0027355488 scopus 로고
    • Treatment planning and placement of implants in the posterior maxillae: Report of 732 consecutive Nobelpharma implants
    • Bahat O. Treatment planning and placement of implants in the posterior maxillae: Report of 732 consecutive Nobelpharma implants. Int J Oral Maxillofac Implants. 1993;8:151-161.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 151-161
    • Bahat, O.1
  • 63
    • 0027567458 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants in posterior partially edentulous patients
    • Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants in posterior partially edentulous patients. Int J Prosthodont. 1993;6:189-196.
    • (1993) Int J Prosthodont , vol.6 , pp. 189-196
    • Zarb, G.A.1    Schmitt, A.2
  • 64
    • 0030184468 scopus 로고    scopus 로고
    • Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter study
    • Henry PJ, Laney WR, Jemt T, et al. Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter study. Int J Oral Maxillofac Implants. 1996;11:450-455.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 450-455
    • Henry, P.J.1    Laney, W.R.2    Jemt, T.3
  • 65
    • 0034268232 scopus 로고    scopus 로고
    • Branemark system implants in the posterior maxilla: Clinical study of 660 implants followed for 5 to 12 years
    • Bahat O. Branemark system implants in the posterior maxilla: Clinical study of 660 implants followed for 5 to 12 years. Int J Oral Maxillofac Implants. 2000;15:646-653.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 646-653
    • Bahat, O.1
  • 66
    • 0036481856 scopus 로고    scopus 로고
    • Implant prosthodontic management of posterior partial edentulism: Long-term follow-up of a prospective study
    • Attard N, Zarb GA. Implant prosthodontic management of posterior partial edentulism: Long-term follow-up of a prospective study. J Can Dent Assoc. 2002;68:118-124.
    • (2002) J Can Dent Assoc , vol.68 , pp. 118-124
    • Attard, N.1    Zarb, G.A.2
  • 67
    • 37349098206 scopus 로고    scopus 로고
    • Lekholm U, Zarb GA. Selección y preparación del paciente. In: Branemark PI, Zarb GA, Albrektsson T. Prótesis tejidointegradas: la osseointegración en la odontología clínic. 12. Berlin: Quintessence; 1987:199-210.
    • Lekholm U, Zarb GA. Selección y preparación del paciente. In: Branemark PI, Zarb GA, Albrektsson T. Prótesis tejidointegradas: la osseointegración en la odontología clínic. Vol. 12. Berlin: Quintessence; 1987:199-210.
  • 68
    • 17844385046 scopus 로고    scopus 로고
    • Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures
    • Herrmann I, Lekholm U, Holm S, et al. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int J Oral Maxillofac Implants. 2005;20:220-230.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 220-230
    • Herrmann, I.1    Lekholm, U.2    Holm, S.3
  • 70
    • 0036367644 scopus 로고    scopus 로고
    • Implant failure with spontaneous rapid exfoliation: Case reports
    • Deas DE, Mikotowicz JJ, Mackey SA, et al. Implant failure with spontaneous rapid exfoliation: Case reports. Implant Dent. 2002;11:235-242.
    • (2002) Implant Dent , vol.11 , pp. 235-242
    • Deas, D.E.1    Mikotowicz, J.J.2    Mackey, S.A.3
  • 71
    • 0027343915 scopus 로고
    • An assessment of survival rates and within-patient clustering of failures for endosseous oral implants
    • Weyant RJ, Burt BA. An assessment of survival rates and within-patient clustering of failures for endosseous oral implants. J Dent Res. 1993;72:2-8.
    • (1993) J Dent Res , vol.72 , pp. 2-8
    • Weyant, R.J.1    Burt, B.A.2
  • 72
    • 0029175464 scopus 로고
    • Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Branemark implants
    • Hutton JE, Heath MR, Chai JY, et al. Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Branemark implants. Int J Oral Maxillofac Implants. 1995;10:33-42.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 33-42
    • Hutton, J.E.1    Heath, M.R.2    Chai, J.Y.3
  • 73
    • 0033140236 scopus 로고    scopus 로고
    • Determination of the success and failure of root-form osseointegrated dental implants
    • Tonetti MS. Determination of the success and failure of root-form osseointegrated dental implants. Adv Dent Res. 1999;13:173-180.
    • (1999) Adv Dent Res , vol.13 , pp. 173-180
    • Tonetti, M.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.