메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1015-1022

Blood flow through channels and clearances in implantable pumps

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD FLOW; MINIATURIZED PUMPS; ROTARY BLOOD PUMPS;

EID: 37249062561     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1115/ICNMM2007-30159     Document Type: Conference Paper
Times cited : (1)

References (31)
  • 1
    • 0030043041 scopus 로고    scopus 로고
    • New devices are helping transform coronary care
    • Wickelgren, I., New devices are helping transform coronary care. Science, 1996. 272: p. 668-670.
    • (1996) Science , vol.272 , pp. 668-670
    • Wickelgren, I.1
  • 2
    • 0025298777 scopus 로고    scopus 로고
    • Goldsmith, M.F., Fully implantable left ventricular assist device may enter clinical trials in 1991. Journal of American Medical Association, 1990. 253: p. 2990-.
    • Goldsmith, M.F., Fully implantable left ventricular assist device may enter clinical trials in 1991. Journal of American Medical Association, 1990. 253: p. 2990-.
  • 3
    • 0021753394 scopus 로고
    • The political history of the artificial heart
    • Strauss, M. J., The political history of the artificial heart. New England Journal of Medicine, 1984. 310: p. 332-336.
    • (1984) New England Journal of Medicine , vol.310 , pp. 332-336
    • Strauss, M.J.1
  • 4
    • 0034940556 scopus 로고    scopus 로고
    • Particle image velocimetry measurements of blood velocity in a continuous flow ventricular assist device
    • Day, S.W., J.C. McDaniel, H.G. Wood, P.E. Allaire, N. Landrot, and A. Curtas, Particle image velocimetry measurements of blood velocity in a continuous flow ventricular assist device. ASAIO Journal, 2001. 47(4): p. 406-411.
    • (2001) ASAIO Journal , vol.47 , Issue.4 , pp. 406-411
    • Day, S.W.1    McDaniel, J.C.2    Wood, H.G.3    Allaire, P.E.4    Landrot, N.5    Curtas, A.6
  • 6
    • 0001480245 scopus 로고
    • Mechanical properties of the red cell membrane: II. Viscoelastic breakdown of the membrane
    • Rand, R.P., Mechanical properties of the red cell membrane: II. Viscoelastic breakdown of the membrane. Biophysical Journal, 1964. 4: p. 303-316.
    • (1964) Biophysical Journal , vol.4 , pp. 303-316
    • Rand, R.P.1
  • 8
    • 84885259018 scopus 로고    scopus 로고
    • Anderson, J.B., Computational flow analysis of a ventricular assist device, in M.S. Thesis in Mechanical and Aerospace Engineering. 1997, University of Virginia.
    • Anderson, J.B., Computational flow analysis of a ventricular assist device, in M.S. Thesis in Mechanical and Aerospace Engineering. 1997, University of Virginia.
  • 9
    • 2142668362 scopus 로고    scopus 로고
    • Computational fluid testing for the design and development of a Heart Assist Pump
    • University of Virginia: Charlottesville, VA. p
    • Curtas, A., Computational fluid testing for the design and development of a Heart Assist Pump, in Mechanical and Aerospace Engineering. 2000, University of Virginia: Charlottesville, VA. p. 97.
    • (2000) Mechanical and Aerospace Engineering , pp. 97
    • Curtas, A.1
  • 10
    • 0034838318 scopus 로고    scopus 로고
    • Computational fluid dynamics as a development tool for rotary blood pumps
    • Burgreen, G., J. Antaki, Z. Wu, and A. Holmes, Computational fluid dynamics as a development tool for rotary blood pumps. Artificial Organs, 2001. 25(5): p. 336-340.
    • (2001) Artificial Organs , vol.25 , Issue.5 , pp. 336-340
    • Burgreen, G.1    Antaki, J.2    Wu, Z.3    Holmes, A.4
  • 11
    • 2442601403 scopus 로고    scopus 로고
    • Computational Fluid Dynamics (CFD) study of the 4th generation prototype of a continuous flow ventricular assist device (VAD)
    • Song, X.W., H.G. Wood, and D.B. Olsen, Computational Fluid Dynamics (CFD) study of the 4th generation prototype of a continuous flow ventricular assist device (VAD), Journal of Biomechanical Engineering - Transactions of the ASME, 2003. 126(2): p. 180-187.
    • (2003) Journal of Biomechanical Engineering - Transactions of the ASME , vol.126 , Issue.2 , pp. 180-187
    • Song, X.W.1    Wood, H.G.2    Olsen, D.B.3
  • 12
    • 0034827843 scopus 로고    scopus 로고
    • Computational fluid dynamics and experimental validation of a microaxial blood pump
    • Apel, J., F. Neudel, and H. Reul, Computational fluid dynamics and experimental validation of a microaxial blood pump. ASAIO Journal, 2001. 47: p. 552-558.
    • (2001) ASAIO Journal , vol.47 , pp. 552-558
    • Apel, J.1    Neudel, F.2    Reul, H.3
  • 13
    • 0002883990 scopus 로고    scopus 로고
    • Use of a commercial CFD package to predict shut-off behaviour of a model centrifugal pump - an appraisal
    • London: Professional Engineering Publishing Limited
    • Potts, I. and T.M. Newton. Use of a commercial CFD package to predict shut-off behaviour of a model centrifugal pump - an appraisal, in CFD in Fluid Machinery Design. 1998. London: Professional Engineering Publishing Limited.
    • (1998) CFD in Fluid Machinery Design
    • Potts, I.1    Newton, T.M.2
  • 14
    • 0242301755 scopus 로고    scopus 로고
    • Studies of turbulence models in a computational fluid dynamics model of a blood pump
    • Song, X.W., H.G. Wood, S.W. Day, and D.B. Olsen, Studies of turbulence models in a computational fluid dynamics model of a blood pump. Artificial Organs, 2003. 27(10): p. 935-937.
    • (2003) Artificial Organs , vol.27 , Issue.10 , pp. 935-937
    • Song, X.W.1    Wood, H.G.2    Day, S.W.3    Olsen, D.B.4
  • 15
    • 0344076158 scopus 로고    scopus 로고
    • Investigation of unsteady flow in a model of a ventricular assist device by numerical modelling and comparison with experiment
    • Konig, C., Clark, C, Mokhtarzadeh-Dehghan, MR, Investigation of unsteady flow in a model of a ventricular assist device by numerical modelling and comparison with experiment. Medical Engineering and Physics, 1999. 21(1): p. 53-64.
    • (1999) Medical Engineering and Physics , vol.21 , Issue.1 , pp. 53-64
    • Konig, C.1    Clark, C.2    Mokhtarzadeh-Dehghan, M.R.3
  • 16
    • 0027236638 scopus 로고
    • A flow visualization study of centrifugal blood pumps developed for long-term usage
    • Araki, K., Y. Taenaka, T. Masuzawa, K. Inoue, T. Nakatani, M. Kinoshota, et al., A flow visualization study of centrifugal blood pumps developed for long-term usage. Artificial Organs, 1993. 17(5): p. 307-312.
    • (1993) Artificial Organs , vol.17 , Issue.5 , pp. 307-312
    • Araki, K.1    Taenaka, Y.2    Masuzawa, T.3    Inoue, K.4    Nakatani, T.5    Kinoshota, M.6
  • 18
    • 0033818385 scopus 로고    scopus 로고
    • Ng, B.T.H., W.K. Chan, S.C.M. Yu, andH.D. Li, Experimental and computational studies of the relative flow field in a centrifugal blood pump. Critical Reviews in Biomedical Engineering, 2000. 28(1-2): p. 119-125.
    • Ng, B.T.H., W.K. Chan, S.C.M. Yu, andH.D. Li, Experimental and computational studies of the relative flow field in a centrifugal blood pump. Critical Reviews in Biomedical Engineering, 2000. 28(1-2): p. 119-125.
  • 19
    • 0024703843 scopus 로고
    • Mean flow velocity patterns within a ventricular assist device
    • Baldwin, J., J. Tarbell, S. Deutsch, and D. Geselowitz, Mean flow velocity patterns within a ventricular assist device. ASAIO Transactions, 1989. 35(3): p. 429-433.
    • (1989) ASAIO Transactions , vol.35 , Issue.3 , pp. 429-433
    • Baldwin, J.1    Tarbell, J.2    Deutsch, S.3    Geselowitz, D.4
  • 20
    • 0036367482 scopus 로고    scopus 로고
    • Flow through an outlet cannula of a rotary ventricular assist device
    • Manning, K.B. and G.E. Miller, Flow through an outlet cannula of a rotary ventricular assist device. Artificial Organs, 2002. 26(8): p. 714-723.
    • (2002) Artificial Organs , vol.26 , Issue.8 , pp. 714-723
    • Manning, K.B.1    Miller, G.E.2
  • 21
    • 0034159635 scopus 로고    scopus 로고
    • Progress on the heartquest VAD - a centrifugal pump with magnetically suspended rotor
    • Bearnson, G., P. Diegel, P. Khanwilkar, P. Allaire, J. Ludlow, D. Cooley, et al., Progress on the heartquest VAD - a centrifugal pump with magnetically suspended rotor. ASAIO Journal, 2000. 46(2): p. 192.
    • (2000) ASAIO Journal , vol.46 , Issue.2 , pp. 192
    • Bearnson, G.1    Diegel, P.2    Khanwilkar, P.3    Allaire, P.4    Ludlow, J.5    Cooley, D.6
  • 23
    • 12044260218 scopus 로고
    • Particle imaging techniques for fluid mechanics
    • Adrian, R.J., Particle imaging techniques for fluid mechanics. Annual Review of Fluid Mechanics, 1991. 23: p. 261-304.
    • (1991) Annual Review of Fluid Mechanics , vol.23 , pp. 261-304
    • Adrian, R.J.1
  • 24
    • 34249836756 scopus 로고
    • Theory of cross-correlation analysis of PIV images
    • Keane, R.D. and R.J. Adrian, Theory of cross-correlation analysis of PIV images. Applied Scientific Research, 1992. 49: p. 191-215.
    • (1992) Applied Scientific Research , vol.49 , pp. 191-215
    • Keane, R.D.1    Adrian, R.J.2
  • 25
    • 33645988590 scopus 로고    scopus 로고
    • Aspect Ratio Effects on Turbulent and Transitional Flow in Rectangular Microchannels as Measured With MicroPIV
    • Li, H. and M.G. Olsen, Aspect Ratio Effects on Turbulent and Transitional Flow in Rectangular Microchannels as Measured With MicroPIV. Journal of Fluids Engineering. 128: p. 305-315.
    • Journal of Fluids Engineering , vol.128 , pp. 305-315
    • Li, H.1    Olsen, M.G.2
  • 26
    • 0036428688 scopus 로고    scopus 로고
    • A prototype HeartQuest ventricular assist device for particle image velocimetry measurements
    • Day, S.W., J.C. McDaniel, H.G. Wood, P.E. Allaire, X.W. Song, P.P. Lemire, et al., A prototype HeartQuest ventricular assist device for particle image velocimetry measurements. Artificial Organs, 2002. 26(11): p. 1002-1005.
    • (2002) Artificial Organs , vol.26 , Issue.11 , pp. 1002-1005
    • Day, S.W.1    McDaniel, J.C.2    Wood, H.G.3    Allaire, P.E.4    Song, X.W.5    Lemire, P.P.6
  • 27
    • 2342556423 scopus 로고    scopus 로고
    • Design and transient computational fluid dynamics study of a continuous axial flow ventricular assist device
    • Song, X.W., A. Untaroiu, H.G. Wood, P.E. Allaire, A.L. Throckmorton, S.W. Day, et al., Design and transient computational fluid dynamics study of a continuous axial flow ventricular assist device. ASAIO Journal, 2004. 50(3): p. 215-224.
    • (2004) ASAIO Journal , vol.50 , Issue.3 , pp. 215-224
    • Song, X.W.1    Untaroiu, A.2    Wood, H.G.3    Allaire, P.E.4    Throckmorton, A.L.5    Day, S.W.6
  • 28
    • 0036630644 scopus 로고    scopus 로고
    • Visualization study of the transient flow in the centirfugal blood pump impeller
    • Tsukiya, T., Y. Taenaka, E. Tatsumi, and H. Takano, Visualization study of the transient flow in the centirfugal blood pump impeller. ASAIO Journal, 2002. 48: p. 431-436.
    • (2002) ASAIO Journal , vol.48 , pp. 431-436
    • Tsukiya, T.1    Taenaka, Y.2    Tatsumi, E.3    Takano, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.