메뉴 건너뛰기




Volumn 85, Issue 1, 2008, Pages 50-55

Explantation of Implantable Defibrillator Leads Using Open Heart Surgery or Percutaneous Techniques

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; DEFIBRILLATOR; DEVICE REMOVAL; FEMALE; HOSPITALIZATION; HUMAN; INTERMETHOD COMPARISON; LENGTH OF STAY; LOG RANK TEST; MAJOR CLINICAL STUDY; MALE; OPEN HEART SURGERY; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROSTHESIS INFECTION; STATISTICAL SIGNIFICANCE; STUDENT T TEST; SURGICAL TECHNIQUE; SURVIVAL RATE; SURVIVAL TIME;

EID: 37249013842     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2007.03.048     Document Type: Article
Times cited : (29)

References (16)
  • 1
    • 0025932993 scopus 로고
    • Erste klinische Erfahrungen mit einem transvenös-subkutanen Defibrillatorsystem
    • Block M., Hammel D., Borggerfe M., et al. Erste klinische Erfahrungen mit einem transvenös-subkutanen Defibrillatorsystem. Z Kardiol 80 (1991) 657-664
    • (1991) Z Kardiol , vol.80 , pp. 657-664
    • Block, M.1    Hammel, D.2    Borggerfe, M.3
  • 2
    • 0034305071 scopus 로고    scopus 로고
    • Danish Pacemaker and ICD Register. 1999
    • Danish Pacemaker and ICD Register. 1999. Pacing Clin Electrophysiol 23 10 Pt 2 (2000) S1-S93
    • (2000) Pacing Clin Electrophysiol , vol.23 , Issue.10 PART 2
  • 3
    • 0001635323 scopus 로고    scopus 로고
    • Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: Indications, facilities, training
    • Love C.J., Wilkoff B.L., Byrd C.L., et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: Indications, facilities, training. Pacing Clin Electrophysiol 23 (2000) 544-551
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 544-551
    • Love, C.J.1    Wilkoff, B.L.2    Byrd, C.L.3
  • 4
    • 0036456712 scopus 로고    scopus 로고
    • Kommentar zu den NASPE-Empfehlungen zur Entfernung von permanent implantierten, transvenösen Herzschrittmacher und Defibrillatorsonden
    • Hemmer W., Fröhlig G., and Markewitz A. Kommentar zu den NASPE-Empfehlungen zur Entfernung von permanent implantierten, transvenösen Herzschrittmacher und Defibrillatorsonden. Z Kardiol 91 (2002) 956-968
    • (2002) Z Kardiol , vol.91 , pp. 956-968
    • Hemmer, W.1    Fröhlig, G.2    Markewitz, A.3
  • 5
    • 0006918490 scopus 로고    scopus 로고
    • Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators
    • Moss A.J., Hall W.J., Cannom D.S., et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med 335 (1996) 1933-1940
    • (1996) N Engl J Med , vol.335 , pp. 1933-1940
    • Moss, A.J.1    Hall, W.J.2    Cannom, D.S.3
  • 6
    • 0033520022 scopus 로고    scopus 로고
    • Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads
    • Epstein L.M., Byrd C.L., Wilkoff B.L., et al. Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads. Circulation 100 (1999) 516-525
    • (1999) Circulation , vol.100 , pp. 516-525
    • Epstein, L.M.1    Byrd, C.L.2    Wilkoff, B.L.3
  • 8
    • 0030966399 scopus 로고    scopus 로고
    • Systemic infection related to endocarditis on pacemaker leads: clinical presentation and management
    • Klug D., Lacroix D., Savoye C., et al. Systemic infection related to endocarditis on pacemaker leads: clinical presentation and management. Circulation 95 (1997) 2098-2107
    • (1997) Circulation , vol.95 , pp. 2098-2107
    • Klug, D.1    Lacroix, D.2    Savoye, C.3
  • 9
    • 0028293672 scopus 로고
    • Implantable cardioverter defibrillator malfunction due to transvenous lead insulation break
    • 245-6
    • Renzulli A., Vitale N., D′Onofrio A., and Cortrufo M. Implantable cardioverter defibrillator malfunction due to transvenous lead insulation break. Pacing Clin Electrophysiol 17 (1994) 245-6
    • (1994) Pacing Clin Electrophysiol , vol.17
    • Renzulli, A.1    Vitale, N.2    DOnofrio, A.3    Cortrufo, M.4
  • 11
    • 0026549531 scopus 로고
    • Removal of infected transvenous leads requiring cardiopulmonary bypass or inflow occlusion
    • Brodmann R., Frame R., Andrew C., and Furman S. Removal of infected transvenous leads requiring cardiopulmonary bypass or inflow occlusion. J Thorac Cardiovasc Surg 103 (1992) 1164-1165
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 1164-1165
    • Brodmann, R.1    Frame, R.2    Andrew, C.3    Furman, S.4
  • 12
    • 0031416389 scopus 로고    scopus 로고
    • Cardiac pacemaker infection: surgical management with and without extracorporal circulation
    • Wilhelm M.J., Schmid C., Hammel D., et al. Cardiac pacemaker infection: surgical management with and without extracorporal circulation. Ann Thorac Surg 64 (1997) 1707-1712
    • (1997) Ann Thorac Surg , vol.64 , pp. 1707-1712
    • Wilhelm, M.J.1    Schmid, C.2    Hammel, D.3
  • 13
    • 0035206889 scopus 로고    scopus 로고
    • Surgical pacemaker lead extraction: 10 years of experience
    • Starck C., Hemmer W., and Böhm J.O. Surgical pacemaker lead extraction: 10 years of experience. Herschr Elektrophy 12 (2001) 217-224
    • (2001) Herschr Elektrophy , vol.12 , pp. 217-224
    • Starck, C.1    Hemmer, W.2    Böhm, J.O.3
  • 14
    • 0027474526 scopus 로고
    • Infected endocardial pacemaker electrodes: successful open intracardiac removal
    • Niederhäuser U., von Segesser L.K., Carrel T.P., et al. Infected endocardial pacemaker electrodes: successful open intracardiac removal. Pacing Clin Electrophysiol 16 (1993) 303-308
    • (1993) Pacing Clin Electrophysiol , vol.16 , pp. 303-308
    • Niederhäuser, U.1    von Segesser, L.K.2    Carrel, T.P.3
  • 15
    • 18244420080 scopus 로고    scopus 로고
    • Pacemaker infective endocarditis
    • Cacoub P., Leprince P., Nataf P., et al. Pacemaker infective endocarditis. Am J Cardiol 82 (1998) 480-484
    • (1998) Am J Cardiol , vol.82 , pp. 480-484
    • Cacoub, P.1    Leprince, P.2    Nataf, P.3
  • 16
    • 0032514609 scopus 로고    scopus 로고
    • Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads
    • Epstein A.E., Kay G.N., Plumb V.J., et al. Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads. Circulation 98 (1998) 1517-1524
    • (1998) Circulation , vol.98 , pp. 1517-1524
    • Epstein, A.E.1    Kay, G.N.2    Plumb, V.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.