메뉴 건너뛰기




Volumn , Issue , 2006, Pages

Robust fault detection for an induction machine

Author keywords

Fault diagnosis; Induction machine; Nonlinear system; Observer; Residual generation; Robustness

Indexed keywords

ASYNCHRONOUS MACHINERY; ELECTRIC LOADS; FAILURE ANALYSIS; MATHEMATICAL MODELS; NONLINEAR SYSTEMS; PARAMETER ESTIMATION; ROBUSTNESS (CONTROL SYSTEMS); TORQUE CONTROL; UNCERTAINTY ANALYSIS;

EID: 36849088457     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/WAC.2006.375960     Document Type: Conference Paper
Times cited : (6)

References (14)
  • 1
    • 33744824338 scopus 로고    scopus 로고
    • Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines
    • Graz, Austria
    • S. Bachir, S. Tnani, J.C. Trigeassou and G. Champenois, "Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines," Proc. EPE'01, Graz, Austria, 2001.
    • (2001) Proc. EPE'01
    • Bachir, S.1    Tnani, S.2    Trigeassou, J.C.3    Champenois, G.4
  • 2
    • 85080011745 scopus 로고
    • Model-based fault detection and isolation using the generalized parity space and the unknown input observer
    • 94, Algiers, September 24-26
    • M.L. Benloucif, "Model-based fault detection and isolation using the generalized parity space and the unknown input observer," Proc. ICSS'94, Algiers, September 24-26, 1994.
    • (1994) Proc. ICSS
    • Benloucif, M.L.1
  • 3
    • 85080005166 scopus 로고    scopus 로고
    • Fault diagnosis using a robust estimation method
    • Nantes, France, July 08-10
    • M.L. Benloucif and M. Staroswiecki, "Fault diagnosis using a robust estimation method," Proc. CIFA-2002, Nantes, France, July 08-10, 2002.
    • (2002) Proc. CIFA-2002
    • Benloucif, M.L.1    Staroswiecki, M.2
  • 4
    • 85079921223 scopus 로고    scopus 로고
    • Modelling of induction machine with stator faults
    • Nantes, France, July 08-10
    • X. Chang, V. Coquempot and C. Christophe, "Modelling of induction machine with stator faults," Proc. CIFA-2002, Nantes, France, July 08-10, 2002.
    • (2002) Proc. CIFA-2002
    • Chang, X.1    Coquempot, V.2    Christophe, C.3
  • 5
    • 85079993857 scopus 로고    scopus 로고
    • Adaptive residual generation for the induction machine diagnosis
    • Nantes, France, July 08-10
    • C. Combastel, S. Gentil and IP. Rognon, "Adaptive residual generation for the induction machine diagnosis," Proc. CIFA-2002, Nantes, France, July 08-10, 2002.
    • (2002) Proc. CIFA-2002
    • Combastel, C.1    Gentil, S.2    Rognon, I.P.3
  • 7
    • 0025421966 scopus 로고
    • Fault diagnosis in dynamic systems using analytical and knowledge based redundancy - a survey and some new results
    • P.M. Frank, "Fault diagnosis in dynamic systems using analytical and knowledge based redundancy - a survey and some new results," Automatica. 1990, 26, pp. 459-474.
    • (1990) Automatica , vol.26 , pp. 459-474
    • Frank, P.M.1
  • 8
    • 85079923001 scopus 로고
    • Enhancement of robustness in observer-based fault detection
    • 94, Espoo, Finland
    • P.M. Frank, "Enhancement of robustness in observer-based fault detection," Proc. SAFEPROCESS'94, Espoo, Finland, 1994.
    • (1994) Proc. SAFEPROCESS
    • Frank, P.M.1
  • 9
    • 0342762071 scopus 로고    scopus 로고
    • Deterministic nonlinear observer based approaches to fault diagnosis: A survey
    • E. Garcia and P.M. Frank, "Deterministic nonlinear observer based approaches to fault diagnosis: A survey," Control Eng. Practice, vol. 5, no. 5, 1997, pp. 663-670.
    • (1997) Control Eng. Practice , vol.5 , Issue.5 , pp. 663-670
    • Garcia, E.1    Frank, P.M.2
  • 10
    • 85080009392 scopus 로고    scopus 로고
    • D. Henry, A. Zolghadri and M. Monsion, Design of a class of non-linear Observers for fault diagnosis, Proc. ECC'99, Karlsruhe, Germany, 1999.
    • D. Henry, A. Zolghadri and "M. Monsion, "Design of a class of non-linear Observers for fault diagnosis," Proc. ECC'99, Karlsruhe, Germany, 1999.
  • 11
    • 0031147879 scopus 로고    scopus 로고
    • Observer-based fault detection and isolation: Robustness and applications
    • R. Patton and J.Chen, "Observer-based fault detection and isolation: Robustness and applications," Control Ens. Practice, vol. 5, no. 5, 1997, pp, 671-682.
    • (1997) Control Ens. Practice , vol.5 , Issue.5 , pp. 671-682
    • Patton, R.1    Chen, J.2
  • 13
    • 0035342066 scopus 로고    scopus 로고
    • Analytical redundancy relations for fault detection and isolation in algebraic dynamic systems
    • M. Staroswiecki and G. Comtet-varga, "Analytical redundancy relations for fault detection and isolation in algebraic dynamic systems," Automatica, 37, 2001, pp. 687-699.
    • (2001) Automatica , vol.37 , pp. 687-699
    • Staroswiecki, M.1    Comtet-varga, G.2
  • 14
    • 0032202684 scopus 로고    scopus 로고
    • Fault detection and isolation in nonlinear dynamic systems: A combined input-output and local approach
    • Q. Zhang, M. Basseville and A. Benyeniste, "Fault detection and isolation in nonlinear dynamic systems: A combined input-output and local approach," Automatica, 34, 1998, pp. 1359-1373.
    • (1998) Automatica , vol.34 , pp. 1359-1373
    • Zhang, Q.1    Basseville, M.2    Benyeniste, A.3