Volumn 33, Issue 1, 2005, Pages 3-18

X-ray imaging physics for nuclear medicine technologists. Part 2: X-ray interactions and image formation

Author keywords

ray interactions; Attenuation; CT; Digital x ray detectors; Screen film x ray detectors; X ray detection; X ray image formation; X ray interactions

Indexed keywords

COMPTON EFFECT; COMPUTER ASSISTED TOMOGRAPHY; DIGITAL IMAGING; IMAGING SYSTEM; INTERFEROMETER; MAGNIFICATION RADIOGRAPHY; MEDICAL PRACTICE; POSITRON EMISSION TOMOGRAPHY; REVIEW; X RAY; X RAY PHOTOELECTRON SPECTROSCOPY; EDUCATION; IMAGE SUBTRACTION; METHODOLOGY; NUCLEAR MEDICINE; RADIATION SCATTERING; RADIOGRAPHY;

EID: 20644453137     PISSN: 00914916     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (96)

References (12)
  • 1
    • 16644397300 scopus 로고    scopus 로고
    • X-ray imaging physics for nuclear medicine technologists. Part 1: Basic principles of x-ray production
    • Seibert JA. X-ray imaging physics for nuclear medicine technologists. Part 1: Basic principles of x-ray production. J Nucl Med Technol. 2004;32:139-147.
    • (2004) J Nucl Med Technol , vol.32 , pp. 139-147
    • Seibert, J.A.1
  • 3
    • 33751229970 scopus 로고    scopus 로고
    • Interactions of x-rays with matter
    • Edinburgh, U.K.: Churchill Livingstone
    • Graham DT, Cloke P. Interactions of x-rays with matter. In: Principles of Radiological Physics. 4th ed. Edinburgh, U.K.: Churchill Livingstone; 2003:288-302.
    • (2003) Principles of Radiological Physics. 4th Ed. , pp. 288-302
    • Graham, D.T.1    Cloke, P.2
  • 5
    • 0000729933 scopus 로고    scopus 로고
    • X-ray production, interaction, and detection in diagnostic imaging
    • Beutel J, Kundel HL, Van Metter RL, eds. Bellingham, WA: SPIE Press
    • Boone JM. X-ray production, interaction, and detection in diagnostic imaging. In: Beutel J, Kundel HL, Van Metter RL, eds. Handbook of Medical Imaging. Bellingham, WA: SPIE Press; 2000:3-78.
    • (2000) Handbook of Medical Imaging , pp. 3-78
    • Boone, J.M.1
  • 6
    • 33751214890 scopus 로고    scopus 로고
    • Code of Federal Regulations, 21 CFR 1020.30 (m). Diagnostic X-Ray Systems and Their Major Components: Beam Quality - (1) Half Value Layer. 4-1-2003. Ref Type: Statute. Washington, DC: Food and Drug Administration, Department of Health and Human Services; 2003
    • Code of Federal Regulations, 21 CFR 1020.30 (m). Diagnostic X-Ray Systems and Their Major Components: Beam Quality-(1) Half Value Layer. 4-1-2003. Ref Type: Statute. Washington, DC: Food and Drug Administration, Department of Health and Human Services; 2003.
  • 10
    • 0037038876 scopus 로고    scopus 로고
    • The physics of computed radiography
    • Rowlands JA. The physics of computed radiography. Phys Med Biol. 2002;47:123-166.
    • (2002) Phys Med Biol , vol.47 , pp. 123-166
    • Rowlands, J.A.1
  • 11
    • 0031029041 scopus 로고    scopus 로고
    • X-ray detectors for digital radiography
    • Yaffe MJ, Rowlands JA. X-ray detectors for digital radiography. Phys Med Biol. 1997;42:1-39.
    • (1997) Phys Med Biol , vol.42 , pp. 1-39
    • Yaffe, M.J.1    Rowlands, J.A.2
  • 12
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography). 1. Description of system
    • Hounsfield GN. Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol. 1973;46:1016-1022.
    • (1973) Br J Radiol , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.