메뉴 건너뛰기




Volumn 55, Issue 5, 2007, Pages 637-646

Percutaneous treatment of diseased saphenous vein grafts: Current state-of-the-art and future directions

Author keywords

Angioplasty, transluminal, percutaneous coronary; Organ graft; Saphenous vein

Indexed keywords

EVEROLIMUS; FIBRINOGEN RECEPTOR ANTAGONIST; IMMUNOSUPPRESSIVE AGENT; PACLITAXEL; RAPAMYCIN; TACROLIMUS; UNCLASSIFIED DRUG; ZOTAROLIMUS;

EID: 36749050323     PISSN: 00264725     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (3)

References (50)
  • 1
    • 0030245599 scopus 로고    scopus 로고
    • Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5065grafts related to survival and reoperation in 1 388 patients during 25 years
    • Fitzgibbon G, Kafka H, Leach A, Keon WJ, Hooper GD, Burton JR. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5065grafts related to survival and reoperation in 1 388 patients during 25 years. J Am Coll Cardiol 1996;28:616-26.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 616-626
    • Fitzgibbon, G.1    Kafka, H.2    Leach, A.3    Keon, W.J.4    Hooper, G.D.5    Burton, J.R.6
  • 2
    • 27744431927 scopus 로고    scopus 로고
    • Efficacy and safety of edifoligide, an E2F transcription factor decoy, for prevention of vein graft failure following coronary artery bypass graft surgery. PREVENT IV: A randomized controlled trial
    • Alexander JH, Hafley G, Harrington RA, Peterson ED, Ferguson TB, Lorenz TJ et al. Efficacy and safety of edifoligide, an E2F transcription factor decoy, for prevention of vein graft failure following coronary artery bypass graft surgery. PREVENT IV: a randomized controlled trial. JAMA 2005;294:2446-54.
    • (2005) JAMA , vol.294 , pp. 2446-2454
    • Alexander, J.H.1    Hafley, G.2    Harrington, R.A.3    Peterson, E.D.4    Ferguson, T.B.5    Lorenz, T.J.6
  • 4
    • 0031056021 scopus 로고    scopus 로고
    • Outcome of reoperative coronary bypass surgery versus coronary angioplasty after previous bypass surgery
    • Weintraub WS, Jones EL, Morris DC, King SB 3rd, Guyton RA, Craver JM. Outcome of reoperative coronary bypass surgery versus coronary angioplasty after previous bypass surgery. Circulation 1997;95:868-77.
    • (1997) Circulation , vol.95 , pp. 868-877
    • Weintraub, W.S.1    Jones, E.L.2    Morris, D.C.3    King 3rd, S.B.4    Guyton, R.A.5    Craver, J.M.6
  • 5
    • 0025100126 scopus 로고
    • Reoperative coronary surgery: Comparative analysis of 6591 patients undergoing primary bypass and 508 patients undergoing reoperative coronary artery bypass
    • Salomon N, Page U, Bigelow J, Krause AH, Okies JE, Metzdorff MT. Reoperative coronary surgery: comparative analysis of 6591 patients undergoing primary bypass and 508 patients undergoing reoperative coronary artery bypass. J Thorac Cardiovasc Surg 1990;100:250-9.
    • (1990) J Thorac Cardiovasc Surg , vol.100 , pp. 250-259
    • Salomon, N.1    Page, U.2    Bigelow, J.3    Krause, A.H.4    Okies, J.E.5    Metzdorff, M.T.6
  • 6
    • 0142043905 scopus 로고    scopus 로고
    • Percutaneous treatment of saphenous vein graft disease the ongoing challenge
    • Baim D. Percutaneous treatment of saphenous vein graft disease the ongoing challenge. J Am Coll Cardiol 2003;42:1370-2.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1370-1372
    • Baim, D.1
  • 8
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group
    • Serruys PW, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyndrickx et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med 1994;331:489-95.
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    de Jaegere, P.2    Kiemeneij, F.3    Macaya, C.4    Rutsch, W.5    Heyndrickx6
  • 9
    • 0027934377 scopus 로고
    • A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators
    • Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. N Engl J Med 1994;331:496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3    Schatz, R.A.4    Savage, M.P.5    Penn, I.6
  • 10
    • 0029089448 scopus 로고
    • Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: The multicenter U.S. Palmaz-Schatz stent experience. The Palmaz-Schatz Stent Study Group
    • Wong SC, Baim DS, Schatz RA, Teirstein PS, King SB, Curry RC et al. Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: the multicenter U.S. Palmaz-Schatz stent experience. The Palmaz-Schatz Stent Study Group. J Am Coll Cardiol 1995;26:704-12.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 704-712
    • Wong, S.C.1    Baim, D.S.2    Schatz, R.A.3    Teirstein, P.S.4    King, S.B.5    Curry, R.C.6
  • 11
    • 9844257578 scopus 로고    scopus 로고
    • Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts
    • Savage M, Douglas J, Fischman D, Pepine CJ, King SB, Werner JA et al. Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts. N Engl J Med 1997;337:740-7.
    • (1997) N Engl J Med , vol.337 , pp. 740-747
    • Savage, M.1    Douglas, J.2    Fischman, D.3    Pepine, C.J.4    King, S.B.5    Werner, J.A.6
  • 12
    • 0344844461 scopus 로고    scopus 로고
    • Randomized study to compare balloon angioplasty and elective stent implantation in venous bypass grafts: The VENESTENT study
    • Hanekamp C, Koolen J, Den Heijer P, Schalij MJ, Piek JJ, Bär FW et al. Randomized study to compare balloon angioplasty and elective stent implantation in venous bypass grafts: the VENESTENT study. Cathet Cardiovasc Interv 2003;60:452-7.
    • (2003) Cathet Cardiovasc Interv , vol.60 , pp. 452-457
    • Hanekamp, C.1    Koolen, J.2    Den Heijer, P.3    Schalij, M.J.4    Piek, J.J.5    Bär, F.W.6
  • 13
    • 2142853537 scopus 로고    scopus 로고
    • Parallel hierarchy of scientific studies in cardiovascular medicine
    • Biondi-Zoccai GG, Agostoni P, Abbate A. Parallel hierarchy of scientific studies in cardiovascular medicine. Ital Heart J 2003;4:819-20.
    • (2003) Ital Heart J , vol.4 , pp. 819-820
    • Biondi-Zoccai, G.G.1    Agostoni, P.2    Abbate, A.3
  • 14
    • 20244377701 scopus 로고    scopus 로고
    • Guidelines for percutaneous coronary interventions: The task force for percutaneous coronary interventions of the European society of cardiology
    • Silber S, Albertsson P, Aviles FF, Camici PJ, Colombo A, Hamm C et al. Guidelines for percutaneous coronary interventions: the task force for percutaneous coronary interventions of the European society of cardiology. Eur Heart J 2005;26:804-47.
    • (2005) Eur Heart J , vol.26 , pp. 804-847
    • Silber, S.1    Albertsson, P.2    Aviles, F.F.3    Camici, P.J.4    Colombo, A.5    Hamm, C.6
  • 15
    • 0032742941 scopus 로고    scopus 로고
    • Retrieval and analysis of particulate debris following saphenous vein graft intervention
    • Webb J, Carere R, Virmani R, Baim D, Teirstein PS, Whitlow P et al. Retrieval and analysis of particulate debris following saphenous vein graft intervention. J Am Coll Cardiol 1999;34:461-7.
    • (1999) J Am Coll Cardiol , vol.34 , pp. 461-467
    • Webb, J.1    Carere, R.2    Virmani, R.3    Baim, D.4    Teirstein, P.S.5    Whitlow, P.6
  • 16
    • 0028110505 scopus 로고
    • The biology of saphenous vein graft occlusion: Etiology and strategies for prevention
    • Bryan AJ, Angelini GD. The biology of saphenous vein graft occlusion: etiology and strategies for prevention. Curr Opin Cardiol 1994;9:641-9.
    • (1994) Curr Opin Cardiol , vol.9 , pp. 641-649
    • Bryan, A.J.1    Angelini, G.D.2
  • 17
    • 0031753204 scopus 로고    scopus 로고
    • Pathology of restenosis in saphenous bypass grafts after long term implantation
    • Depre C, Havaux X, Wijns W. Pathology of restenosis in saphenous bypass grafts after long term implantation. Am J Clin Pathol 1998;110:378-84.
    • (1998) Am J Clin Pathol , vol.110 , pp. 378-384
    • Depre, C.1    Havaux, X.2    Wijns, W.3
  • 18
    • 0027458580 scopus 로고
    • Histology after stenting of human saphenous vein bypass grafts: Observations from surgically excised grafts 3 to 320 days after stent implantation
    • Van Beusekom H, Van Der Giessen W, Van Suylen R, Bos E, Bosman FT, Serruys WP. Histology after stenting of human saphenous vein bypass grafts: observations from surgically excised grafts 3 to 320 days after stent implantation. J Am Coll Cardiol 1993;21:45-54.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 45-54
    • Van Beusekom, H.1    Van Der Giessen, W.2    Van Suylen, R.3    Bos, E.4    Bosman, F.T.5    Serruys, W.P.6
  • 20
    • 0034711168 scopus 로고    scopus 로고
    • Treatment of aortocoronary vein graft lesions with membrane-covered stents: A multicenter surveillance trial
    • Baldus S, Köster R, Elsner M, Walter DH, Arnold R, Auch-Schwelch W et al. Treatment of aortocoronary vein graft lesions with membrane-covered stents: A multicenter surveillance trial. Circulation 2000;102:2024-7.
    • (2000) Circulation , vol.102 , pp. 2024-2027
    • Baldus, S.1    Köster, R.2    Elsner, M.3    Walter, D.H.4    Arnold, R.5    Auch-Schwelch, W.6
  • 21
    • 10744222369 scopus 로고    scopus 로고
    • A randomized trial of polytetrafluoroethylene-membrane-covered stents compared with conventional stents in aortocoronary saphenous vein grafts
    • Schächinger V, Hamm CW, Münzel T, Haude M, Baldus S, Grube E et al. A randomized trial of polytetrafluoroethylene-membrane-covered stents compared with conventional stents in aortocoronary saphenous vein grafts. J Am Coll Cardiol 2003;42:1360-9.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1360-1369
    • Schächinger, V.1    Hamm, C.W.2    Münzel, T.3    Haude, M.4    Baldus, S.5    Grube, E.6
  • 22
    • 0038164591 scopus 로고    scopus 로고
    • Randomized evaluation of polytetrafluoroethylene- covered stent in saphenous vein grafts: The Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) Trial
    • Stankovic G, Colombo A, Presbitero P, van den Branden F, Inglese L, Cernigliaro C et al. Randomized evaluation of polytetrafluoroethylene- covered stent in saphenous vein grafts: the Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) Trial. Circulation 2003;108:37-42.
    • (2003) Circulation , vol.108 , pp. 37-42
    • Stankovic, G.1    Colombo, A.2    Presbitero, P.3    van den Branden, F.4    Inglese, L.5    Cernigliaro, C.6
  • 23
    • 33748333147 scopus 로고    scopus 로고
    • Pivotal, randomized U.S. study of the Symbiot covered stent system in patients with saphenous vein graft disease: Eight-month angiographic and clinical results from the Symbiot III trial
    • Turco MA, Buchbinder M, Popma JJ, Weissman NJ, Mann T, Doucet S et al. Pivotal, randomized U.S. study of the Symbiot covered stent system in patients with saphenous vein graft disease: Eight-month angiographic and clinical results from the Symbiot III trial. Catheter Cardiovasc Interv 2006;68:379-88.
    • (2006) Catheter Cardiovasc Interv , vol.68 , pp. 379-388
    • Turco, M.A.1    Buchbinder, M.2    Popma, J.J.3    Weissman, N.J.4    Mann, T.5    Doucet, S.6
  • 24
    • 20144368666 scopus 로고    scopus 로고
    • A prospective, randomized U.S. trial of the PTFE-covered JOSTENT for the treatment of diseased saphenous vein grafts: The BARRICADE trial (abstr.)
    • Stone G, Goldberg S, Mehran R. A prospective, randomized U.S. trial of the PTFE-covered JOSTENT for the treatment of diseased saphenous vein grafts: the BARRICADE trial (abstr.). J Am Coll Cardiol 2005;45(suppl A):27A.
    • (2005) J Am Coll Cardiol , vol.45 , Issue.SUPPL. A
    • Stone, G.1    Goldberg, S.2    Mehran, R.3
  • 25
    • 0037133682 scopus 로고    scopus 로고
    • Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
    • Baim DS, Wahr D, George B, Leon MB, Greenberg J, Cutlip L et al. Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts. Circulation 2002;105:1285-90.
    • (2002) Circulation , vol.105 , pp. 1285-1290
    • Baim, D.S.1    Wahr, D.2    George, B.3    Leon, M.B.4    Greenberg, J.5    Cutlip, L.6
  • 26
    • 19944428047 scopus 로고    scopus 로고
    • Six-month angiographic results of primary angioplasty with adjunctive PercuSurge GuardWire device support: Evaluation of the restenotic rate of the target lesion and the fate of the distal balloon occlusion site
    • Wu CJ, Yang CH, Fang CY, Chang HW, Chen SM, Hung WC et al. Six-month angiographic results of primary angioplasty with adjunctive PercuSurge GuardWire device support: evaluation of the restenotic rate of the target lesion and the fate of the distal balloon occlusion site. Catheter Cardiovasc Interv 2005;64:35-42.
    • (2005) Catheter Cardiovasc Interv , vol.64 , pp. 35-42
    • Wu, C.J.1    Yang, C.H.2    Fang, C.Y.3    Chang, H.W.4    Chen, S.M.5    Hung, W.C.6
  • 27
    • 34447307685 scopus 로고    scopus 로고
    • Acute and mid-term local vascular effects of compliant balloon inflation (GuardWire system) on saphenous vein bypass grafts: An angiographic analysis
    • Agostoni P, Vermeersch P, Vydt T, Debrauwere J, van den Heuvel P, Convens C et al. Acute and mid-term local vascular effects of compliant balloon inflation (GuardWire system) on saphenous vein bypass grafts: an angiographic analysis. Int J Cardiol 2007;120:227-31.
    • (2007) Int J Cardiol , vol.120 , pp. 227-231
    • Agostoni, P.1    Vermeersch, P.2    Vydt, T.3    Debrauwere, J.4    van den Heuvel, P.5    Convens, C.6
  • 28
    • 0043075814 scopus 로고    scopus 로고
    • Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts
    • Stone GW, Rogers C, Hermiller J, Feldman R, Hall P, Haber R et al. Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts. Circulation 2003;108:548-53.
    • (2003) Circulation , vol.108 , pp. 548-553
    • Stone, G.W.1    Rogers, C.2    Hermiller, J.3    Feldman, R.4    Hall, P.5    Haber, R.6
  • 30
    • 0037058871 scopus 로고    scopus 로고
    • Lack of benefit from intravenous platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment for percutaneous interventions of aortocoronary bypass grafts: A pooled analysis of five randomized clinical trials
    • Roffi M, Mukherjee D, Chew DP, Bhatt DL, Cho L, Robbins MA et al. Lack of benefit from intravenous platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment for percutaneous interventions of aortocoronary bypass grafts: a pooled analysis of five randomized clinical trials. Circulation 2002;106:3063-7.
    • (2002) Circulation , vol.106 , pp. 3063-3067
    • Roffi, M.1    Mukherjee, D.2    Chew, D.P.3    Bhatt, D.L.4    Cho, L.5    Robbins, M.A.6
  • 31
    • 0141765805 scopus 로고    scopus 로고
    • SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses J, Leon M, Popma J, Fitzgerald PJ, Holmes DR, O'Shaugnessy C et al., SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Eng J Med 2003;349:1315-23.
    • (2003) N Eng J Med , vol.349 , pp. 1315-1323
    • Moses, J.1    Leon, M.2    Popma, J.3    Fitzgerald, P.J.4    Holmes, D.R.5    O'Shaugnessy, C.6
  • 32
    • 9144249927 scopus 로고    scopus 로고
    • TAXUS-IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease
    • Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaugnessy C, Mann JT et al., TAXUS-IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221-31.
    • (2004) N Engl J Med , vol.350 , pp. 221-231
    • Stone, G.W.1    Ellis, S.G.2    Cox, D.A.3    Hermiller, J.4    O'Shaugnessy, C.5    Mann, J.T.6
  • 33
    • 33747613296 scopus 로고    scopus 로고
    • ENDEAVOR II Investigators. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: Clinical and angiographic results of the ENDEAVOR II trial
    • Fajadet J, Wijns W, Laarman GJ, Kuck KH, Ormiston J, Munzel T et al.; ENDEAVOR II Investigators. Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial. Circulation 2006;114:798-806.
    • (2006) Circulation , vol.114 , pp. 798-806
    • Fajadet, J.1    Wijns, W.2    Laarman, G.J.3    Kuck, K.H.4    Ormiston, J.5    Munzel, T.6
  • 35
    • 29244439559 scopus 로고    scopus 로고
    • Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention
    • Chu WW, Rha SW, Kuchulakanti PK, Cheneau E, Torguson R, Pinnow E et al. Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention. Am J Cardiol 2006;97:34-7.
    • (2006) Am J Cardiol , vol.97 , pp. 34-37
    • Chu, W.W.1    Rha, S.W.2    Kuchulakanti, P.K.3    Cheneau, E.4    Torguson, R.5    Pinnow, E.6
  • 36
    • 2442596042 scopus 로고    scopus 로고
    • Effectiveness of the sirolimus-eluting stent in the treatment of saphenous vein graft disease
    • Hoye A, Lemos PA, Arampatzis CA, Saia F, Tanabe K, Degertekin M et al. Effectiveness of the sirolimus-eluting stent in the treatment of saphenous vein graft disease. J Invasive Cardiol 2004;16:230-3.
    • (2004) J Invasive Cardiol , vol.16 , pp. 230-233
    • Hoye, A.1    Lemos, P.A.2    Arampatzis, C.A.3    Saia, F.4    Tanabe, K.5    Degertekin, M.6
  • 37
    • 23044442806 scopus 로고    scopus 로고
    • Immediate and one-year outcome of percutaneous intervention of saphenous vein graft disease with paclitaxel-eluting stents
    • Tsuchida K, Ong AT, Aoki J, van Mieghem CA, Rodriguez-Granillo GA, Valgimigli M et al. Immediate and one-year outcome of percutaneous intervention of saphenous vein graft disease with paclitaxel-eluting stents. Am J Cardiol 2005;96:395-8.
    • (2005) Am J Cardiol , vol.96 , pp. 395-398
    • Tsuchida, K.1    Ong, A.T.2    Aoki, J.3    van Mieghem, C.A.4    Rodriguez-Granillo, G.A.5    Valgimigli, M.6
  • 39
    • 33947310234 scopus 로고    scopus 로고
    • BASKET Investigators. Targeted stent use in clinical practice based on evidence from the Basel Stent Cost Effectiveness Trial (BASKET)
    • Brunner-La Rocca HP, Kaiser C, Pfisterer M; BASKET Investigators. Targeted stent use in clinical practice based on evidence from the Basel Stent Cost Effectiveness Trial (BASKET). Eur Heart J 2007;28:719-25.
    • (2007) Eur Heart J , vol.28 , pp. 719-725
    • Brunner-La Rocca, H.P.1    Kaiser, C.2    Pfisterer, M.3
  • 40
    • 34547754031 scopus 로고    scopus 로고
    • Targeted stent use in clinical practice based on evidence from the Basel Stent Cost Effectiveness Trial (BASKET)
    • Jul 2; E-pub ahead of print
    • Agostoni P, Vermeersch P, Verheye S, Van den Heuvel P, Convens C, Van den Branden F et al. Targeted stent use in clinical practice based on evidence from the Basel Stent Cost Effectiveness Trial (BASKET). Eur Heart J 2007 Jul 2; E-pub ahead of print.
    • (2007) Eur Heart J
    • Agostoni, P.1    Vermeersch, P.2    Verheye, S.3    Van den Heuvel, P.4    Convens, C.5    Van den Branden, F.6
  • 41
    • 21144454374 scopus 로고    scopus 로고
    • Incidence and predictors of target vessel revascularization and clinical event rates of the sirolimus-eluting coronary stent (results from the prospective multicenter german cypher stent registry)
    • Zahn R, Hamm C, Schneider S, Zeymer U, Nienaber CA, Richardt G et al. Incidence and predictors of target vessel revascularization and clinical event rates of the sirolimus-eluting coronary stent (results from the prospective multicenter german cypher stent registry). Am J Cardiol 2005;95:1302-8.
    • (2005) Am J Cardiol , vol.95 , pp. 1302-1308
    • Zahn, R.1    Hamm, C.2    Schneider, S.3    Zeymer, U.4    Nienaber, C.A.5    Richardt, G.6
  • 42
    • 33845410666 scopus 로고    scopus 로고
    • Randomized double-blind comparison of sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts: 6-month angiographic, intravascular ultrasound and clinical follow up of the RRISC trial
    • Vermeersch P, Agostoni P, Verheye S, van den Heuvel P, Convens C, Braining N et al. Randomized double-blind comparison of sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts: 6-month angiographic, intravascular ultrasound and clinical follow up of the RRISC trial. J Am Coll Cardiol 2006;48:2423-31.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2423-2431
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    van den Heuvel, P.4    Convens, C.5    Braining, N.6
  • 43
    • 34250812581 scopus 로고    scopus 로고
    • Intravascular ultrasound assessment of sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts (from the RRISC [Reduction of Restenosis In Saphenous vein grafts with Cypher sirolimus-eluting stent] trial)
    • Agostoni P, Vermeersch P, Semeraro O, Verheye S, van Langenhove G, van den Heuvel P et al. Intravascular ultrasound assessment of sirolimus-eluting stent versus bare metal stent implantation in diseased saphenous vein grafts (from the RRISC [Reduction of Restenosis In Saphenous vein grafts with Cypher sirolimus-eluting stent] trial). Am J Cardiol 2007;100:52-8.
    • (2007) Am J Cardiol , vol.100 , pp. 52-58
    • Agostoni, P.1    Vermeersch, P.2    Semeraro, O.3    Verheye, S.4    van Langenhove, G.5    van den Heuvel, P.6
  • 44
    • 11144356135 scopus 로고    scopus 로고
    • Relation of final lumen dimensions in saphenous vein grafts after stent implantation to outcome
    • Iakovou I, Dangas G, Mintz GS, Mehran R, Kobayashi Y, Aymong E et al. Relation of final lumen dimensions in saphenous vein grafts after stent implantation to outcome. Am J Cardiol 2004;93:963-8.
    • (2004) Am J Cardiol , vol.93 , pp. 963-968
    • Iakovou, I.1    Dangas, G.2    Mintz, G.S.3    Mehran, R.4    Kobayashi, Y.5    Aymong, E.6
  • 45
    • 0030967488 scopus 로고    scopus 로고
    • Late myocardial ischemic events after saphenous vein graft intervention - importance of initially "nonsignificant" vein graft lesions
    • Ellis SG, Brener SJ, DeLuca S, Tuzcu EM, Raymond RE, Whitlow PL et al. Late myocardial ischemic events after saphenous vein graft intervention - importance of initially "nonsignificant" vein graft lesions. Am J Cardiol 1997;79:1460-4.
    • (1997) Am J Cardiol , vol.79 , pp. 1460-1464
    • Ellis, S.G.1    Brener, S.J.2    DeLuca, S.3    Tuzcu, E.M.4    Raymond, R.E.5    Whitlow, P.L.6
  • 47
    • 33847167065 scopus 로고    scopus 로고
    • Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study
    • Daemen J, Wenaweser P, Tsuchida K. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet 2007;369:667-78.
    • (2007) Lancet , vol.369 , pp. 667-678
    • Daemen, J.1    Wenaweser, P.2    Tsuchida, K.3
  • 48
    • 33846803611 scopus 로고    scopus 로고
    • Late thrombosis of drug-eluting stents: A meta-analysis of randomized clinical trials
    • Bavry AA, Kumbhani DJ, Helton TJ, Borek PP, Mood GR, Bhatt DL. Late thrombosis of drug-eluting stents: a meta-analysis of randomized clinical trials. Am J Med 2006;119:1056-61.
    • (2006) Am J Med , vol.119 , pp. 1056-1061
    • Bavry, A.A.1    Kumbhani, D.J.2    Helton, T.J.3    Borek, P.P.4    Mood, G.R.5    Bhatt, D.L.6
  • 49
    • 34447120247 scopus 로고    scopus 로고
    • Increased late mortality after sirolimus-eluting stents versus bare metal stents in diseased saphenous vein grafts: Results from the randomized DELAYED RRISC trial
    • Vermeersch P, Agostoni P, Verheye S, van den Heuvel P, Convens C, van den Branden F et al. Increased late mortality after sirolimus-eluting stents versus bare metal stents in diseased saphenous vein grafts: results from the randomized DELAYED RRISC trial. J Am Coll Cardiol 2007;50:261-7.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 261-267
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    van den Heuvel, P.4    Convens, C.5    van den Branden, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.