1
-
-
0037400997
-
Biomechanical investigation of pedicle screw-vertebrae complex: A finite element approach using bonded and contact interface conditions
-
Chen SI, Lin RM, Chang CH. Biomechanical investigation of pedicle screw-vertebrae complex: a finite element approach using bonded and contact interface conditions. Med Eng Phys. 2003; 25:275-82.
-
(2003)
Med Eng Phys
, vol.25
, pp. 275-282
-
-
Chen, S.I.1
Lin, R.M.2
Chang, C.H.3
-
2
-
-
0028719283
-
-
Edwards CC, Garfin SR, Melkerson MN, Mishra NK, Winter RB, Yuan HA. Symposium: lumbar spine fixation - the pedicle screw controversy. Contemp Orthop. 1994; 29:439-54.
-
(1994)
Symposium: Lumbar spine fixation - the pedicle screw controversy. Contemp Orthop
, vol.29
, pp. 439-454
-
-
Edwards, C.C.1
Garfin, S.R.2
Melkerson, M.N.3
Mishra, N.K.4
Winter, R.B.5
Yuan, H.A.6
-
3
-
-
0031759821
-
A prospective study of 342 patients using transpedicular fixation instrumentation for lumbosacral spine arthrodesis
-
Simmons JW, Andersson GB, Russell GS, Hadjipavlou AG. A prospective study of 342 patients using transpedicular fixation instrumentation for lumbosacral spine arthrodesis. J Spinal Disord. 1998; 11:367-74.
-
(1998)
J Spinal Disord
, vol.11
, pp. 367-374
-
-
Simmons, J.W.1
Andersson, G.B.2
Russell, G.S.3
Hadjipavlou, A.G.4
-
4
-
-
0034881609
-
Role of cortical and cancellous bone of the vertebral pedicle in implant fixation
-
Defino HL, Vendrame JR. Role of cortical and cancellous bone of the vertebral pedicle in implant fixation. Eur Spine. J 2001; 10:325-33.
-
(2001)
Eur Spine. J
, vol.10
, pp. 325-333
-
-
Defino, H.L.1
Vendrame, J.R.2
-
6
-
-
0034873699
-
Effects of hole preparation on screw pullout resistance and insertional torque: A biomechanical study
-
Öktenoglu B, Ferreira L, Andalkar B, Özer A, Sariöglu A, Benzel E. Effects of hole preparation on screw pullout resistance and insertional torque: a biomechanical study. J Neurosurg. 2006; 94:91-6.
-
(2006)
J Neurosurg
, vol.94
, pp. 91-96
-
-
Öktenoglu, B.1
Ferreira, L.2
Andalkar, B.3
Özer, A.4
Sariöglu, A.5
Benzel, E.6
-
7
-
-
0032229511
-
-
Van Ooterwyck K, Duyck J, Vander S, Van der Perre G, De Cooman M, Lievens S.,et al. I. The influence of bone mechanical properties and implant fixation upon bone loading around implants. Clin Oral Impl Res. 1998; 9:407-18.
-
Van Ooterwyck K, Duyck J, Vander S, Van der Perre G, De Cooman M, Lievens S.,et al. I. The influence of bone mechanical properties and implant fixation upon bone loading around implants. Clin Oral Impl Res. 1998; 9:407-18.
-
-
-
-
9
-
-
34347144707
-
Einbettung von Metallschrauben im Knochen und die Heilungsvorgänge des Knochengewebes unter dem Einfluss der stabilen Osteosynthese
-
Wagner H. Die Einbettung von Metallschrauben im Knochen und die Heilungsvorgänge des Knochengewebes unter dem Einfluss der stabilen Osteosynthese. Langenbecks Arch Klin Chir. 1963; 305:28-40.
-
(1963)
Langenbecks Arch Klin Chir
, vol.305
, pp. 28-40
-
-
Die, W.H.1
-
10
-
-
36749070012
-
Estudo da influência da técnica de preparação dos pedículos vertebrais na resistência ao arrancamento dos implantes
-
Abrahão F, Shimano A, Defino H. Estudo da influência da técnica de preparação dos pedículos vertebrais na resistência ao arrancamento dos implantes. COLUNA/COLUMNA. 2003; 2:111-7.
-
(2003)
COLUNA/COLUMNA
, vol.2
, pp. 111-117
-
-
Abrahão, F.1
Shimano, A.2
Defino, H.3
-
11
-
-
0030898587
-
Pedicle screw fixation in spinal disorders: A European view
-
Boos N, Webb JK. Pedicle screw fixation in spinal disorders: a European view. Eur Spine J. 1997; 6:2-18.
-
(1997)
Eur Spine J
, vol.6
, pp. 2-18
-
-
Boos, N.1
Webb, J.K.2
-
13
-
-
32944462062
-
Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine
-
Carmouche JJ, Molinari RW, Gerlinger T, Devine J, Patience T. Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine. J Neurosurg Spine. 2005; 3:364-70.
-
(2005)
J Neurosurg Spine
, vol.3
, pp. 364-370
-
-
Carmouche, J.J.1
Molinari, R.W.2
Gerlinger, T.3
Devine, J.4
Patience, T.5
-
14
-
-
0028258268
-
Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws
-
Daftari TK, Horton WC, Hutton WC. Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws. J Spinal Disord. 1994; 7:139-45.
-
(1994)
J Spinal Disord
, vol.7
, pp. 139-145
-
-
Daftari, T.K.1
Horton, W.C.2
Hutton, W.C.3
-
15
-
-
0025351033
-
Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study
-
Skinner R, Maybee J, Transfeldt E, Venter R, Chalmers W. Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study. Spine. 1990; 15:195-201.
-
(1990)
Spine
, vol.15
, pp. 195-201
-
-
Skinner, R.1
Maybee, J.2
Transfeldt, E.3
Venter, R.4
Chalmers, W.5
-
16
-
-
0027197109
-
The effects of depth of penetration, screw orientation, and bone density on sacral screw fixation
-
Smith SA, Abitbol JJ, Carlson GD, Anderson DR, Taggart KW, et al. The effects of depth of penetration, screw orientation, and bone density on sacral screw fixation. Spine. 1993;18:1006-10.
-
(1993)
Spine
, vol.18
, pp. 1006-1010
-
-
Smith, S.A.1
Abitbol, J.J.2
Carlson, G.D.3
Anderson, D.R.4
Taggart, K.W.5
-
17
-
-
0016715584
-
The reaction of cortical bone to compression by screw threads
-
Schtzker J, Horne J. The reaction of cortical bone to compression by screw threads. Clin Orthop Relat Res. 1975; (111):263-5.
-
(1975)
Clin Orthop Relat Res
, vol.111
, pp. 263-265
-
-
Schtzker, J.1
Horne, J.2
-
18
-
-
0029825385
-
Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone
-
Kwok AW, Finkelstein JA, Woodside T, Hearn TC, Hu RW. Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone. Spine. 1996; 21:2429-34.
-
(1996)
Spine
, vol.21
, pp. 2429-2434
-
-
Kwok, A.W.1
Finkelstein, J.A.2
Woodside, T.3
Hearn, T.C.4
Hu, R.W.5
-
19
-
-
0026089378
-
Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae
-
George DC, Krag MH, Johnson CC, Van Hal ME, Haugh LD, Grobler LJ. Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine. 1991; 16:181-4.
-
(1991)
Spine
, vol.16
, pp. 181-184
-
-
George, D.C.1
Krag, M.H.2
Johnson, C.C.3
Van Hal, M.E.4
Haugh, L.D.5
Grobler, L.J.6
-
20
-
-
0031044771
-
Comparative pull-out strength of tapped and untapped pilot holes for bicortical anterior cervical screws
-
Ronderos JF, Jacobowitz R, Sonntag VK, Crawford NR, Dickman CA. Comparative pull-out strength of tapped and untapped pilot holes for bicortical anterior cervical screws. Spine. 1997; 22:167-70.
-
(1997)
Spine
, vol.22
, pp. 167-170
-
-
Ronderos, J.F.1
Jacobowitz, R.2
Sonntag, V.K.3
Crawford, N.R.4
Dickman, C.A.5
-
21
-
-
0024565314
-
Comparison of compression and torque measurements of self- tapping and pre-tapped screw
-
Phillips J, Rahn B. Comparison of compression and torque measurements of self- tapping and pre-tapped screw. Plas Reconstr Surg. 1989; 83:447-56.
-
(1989)
Plas Reconstr Surg
, vol.83
, pp. 447-456
-
-
Phillips, J.1
Rahn, B.2
|