메뉴 건너뛰기




Volumn 9, Issue 2, 2004, Pages 132-136

Feasibility of on-chip detection of endotoxin by LAL test

Author keywords

Endotoxin; Kinetic chromogenic assay; Lab on a chip; LAL test; Microfluidic chip; PDMS

Indexed keywords

ENDOTOXIN; LAB-ON-A-CHIP; LAL TEST; MICROFLUIDIC CHIP; PDMS;

EID: 36649020507     PISSN: 12268372     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02932996     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 0035034103 scopus 로고    scopus 로고
    • Microchips, microarrays, biochips and nanochips: Personal laboratories for the 21st century
    • Kricka, L. J. (2001) Microchips, microarrays, biochips and nanochips: Personal laboratories for the 21st century. Clin. Chim. Acta 307: 219-223.
    • (2001) Clin. Chim. Acta , vol.307 , pp. 219-223
    • Kricka, L.J.1
  • 2
    • 0035326230 scopus 로고    scopus 로고
    • Integrated plastic microfluidic devices with ESI-MS for drug screening and residue analysis
    • Yun, J., P. C. Wang, L. E. Locascio, and C. S. Lee (2001) Integrated plastic microfluidic devices with ESI-MS for drug screening and residue analysis. Anal. Chem. 73: 2048-2053.
    • (2001) Anal. Chem. , vol.73 , pp. 2048-2053
    • Yun, J.1    Wang, P.C.2    Locascio, L.E.3    Lee, C.S.4
  • 3
    • 0036643808 scopus 로고    scopus 로고
    • PDMS-based microfluidic devices for biomedical applications
    • Fujii, T. (2002) PDMS-based microfluidic devices for biomedical applications. Microelec. Eng. 61-62: 907-914.
    • (2002) Microelec. Eng. , vol.61-62 , pp. 907-914
    • Fujii, T.1
  • 6
    • 49049149901 scopus 로고
    • A new (1→3)-β-d-glucan-mediated coagulation pathway found in Limulus amoebocyte lysate
    • Takashi, M., T. Shigenori, N. Takanori, and I. Sadaaki (1981) A new (1→3)-β-d-glucan-mediated coagulation pathway found in Limulus amoebocyte lysate. FEBS Lett. 129: 318-321.
    • (1981) FEBS Lett. , vol.129 , pp. 318-321
    • Takashi, M.1    Shigenori, T.2    Takanori, N.3    Sadaaki, I.4
  • 7
    • 0016687567 scopus 로고
    • Principle and applications of the Limulus test for pyrogen in parenteral drugs
    • James, F. C. (1975) Principle and applications of the Limulus test for pyrogen in parenteral drugs. Bull. Parenter. Drug. Assoc. 29: 122-130.
    • (1975) Bull. Parenter. Drug. Assoc. , vol.29 , pp. 122-130
    • James, F.C.1
  • 8
    • 0035426586 scopus 로고    scopus 로고
    • A new era in pyrogen testing
    • Jeak, J. D. and H. Bow (2001) A new era in pyrogen testing. Trens Biotechnol. 19: 277-281.
    • (2001) Trens Biotechnol. , vol.19 , pp. 277-281
    • Jeak, J.D.1    Bow, H.2
  • 9
    • 0021940486 scopus 로고
    • Turbidometric method of quantifying serum inhibirion of Limulus amoebocyte lysate
    • Novitsky, T. J., P. F. Roslansky, and G. R. Siber (1985) Turbidometric method of quantifying serum inhibirion of Limulus amoebocyte lysate. J. Clin. Microbiol. 20: 211-216.
    • (1985) J. Clin. Microbiol. , vol.20 , pp. 211-216
    • Novitsky, T.J.1    Roslansky, P.F.2    Siber, G.R.3
  • 10
    • 0024508656 scopus 로고
    • Single-step, chromogenic Limulus amoebocyte lysate assay for endotoxin
    • Gene, K. L., F. R. Priscilla, and J. N. Thomas (1989) Single-step, chromogenic Limulus amoebocyte lysate assay for endotoxin. J. Clin. Microbiol. 27: 947-951.
    • (1989) J. Clin. Microbiol. , vol.27 , pp. 947-951
    • Gene, K.L.1    Priscilla, F.R.2    Thomas, J.N.3
  • 11
    • 0017440396 scopus 로고
    • Detection of endotoxin in biological products by the Limulus test
    • James, F. C. and M. P. Susan (1977) Detection of endotoxin in biological products by the Limulus test. Dev. Biol. Stand. 34: 7-13.
    • (1977) Dev. Biol. Stand. , vol.34 , pp. 7-13
    • James, F.C.1    Susan, M.P.2
  • 12
    • 70349731892 scopus 로고    scopus 로고
    • 7th ed
    • Korean Pharmacopoeia, 7th ed. (1997) 969-973.
    • (1997) Korean Pharmacopoeia , pp. 969-973
  • 13
    • 0026658378 scopus 로고
    • Viability in the LAL test: Comparison of three kinetic methods for the testing of pharmaceutical products
    • Karen, Z. M. and W. L. Cindy (1992) Viability in the LAL test: Comparison of three kinetic methods for the testing of pharmaceutical products. J. Parenter. Sci. Technol. 46: 69-72.
    • (1992) J. Parenter. Sci. Technol. , vol.46 , pp. 69-72
    • Karen, Z.M.1    Cindy, W.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.