메뉴 건너뛰기




Volumn 46, Issue 10, 2007, Pages 30-32

Submersible reference electrodes revisited

Author keywords

[No Author keywords available]

Indexed keywords

STRUCTURE-TO-ELECTROLYTE VOLTAGES; SUBMERSIBLE REFERENCE ELECTRODES;

EID: 36549073277     PISSN: 00941492     EISSN: None     Source Type: Trade Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (3)
  • 1
    • 36549073296 scopus 로고    scopus 로고
    • NACE Standard RP0176-2003, Corrosion Control of Steel Fixed Offshore Structures Associated with Petroleum Production (Houston, TX: NACE International).
    • NACE Standard RP0176-2003, "Corrosion Control of Steel Fixed Offshore Structures Associated with Petroleum Production" (Houston, TX: NACE International).
  • 2
    • 11644257551 scopus 로고    scopus 로고
    • Chemical and Environmental Influences on Copper/Copper Sulfate Reference Electrode Half-Cell Potential
    • MP 37, 5
    • S.J. Pawel, R.J. Lopez, E. Ondak, "Chemical and Environmental Influences on Copper/Copper Sulfate Reference Electrode Half-Cell Potential," MP 37, 5 (1998): p. 23-29.
    • (1998) , pp. 23-29
    • Pawel, S.J.1    Lopez, R.J.2    Ondak, E.3
  • 3
    • 70350204248 scopus 로고
    • Tests Indicate the Ag/AgCl Electrode Is Ideal Reference Cell in Sea Water
    • MP 11, 5
    • M.H. Peterson, R.E. Groover, "Tests Indicate the Ag/AgCl Electrode Is Ideal Reference Cell in Sea Water," MP 11, 5 (1972): p. 19-22.
    • (1972) , pp. 19-22
    • Peterson, M.H.1    Groover, R.E.2