메뉴 건너뛰기




Volumn 35, Issue 12, 2007, Pages 2118-2125

Clinical comparison of fixation methods for patellar bone quadriceps tendon autografts in anterior cruciate ligament reconstruction: Absorbable cross-pins versus absorbable screws

Author keywords

Autograft; Cross pins; Operative care; Patellar bone quadriceps tendon; Rupture of the anterior cruciate ligament

Indexed keywords

ADULT; ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION; ARTHROMETRY; ARTICLE; BIODEGRADABLE IMPLANT; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; FOLLOW UP; FRACTURE FIXATION; HUMAN; INJURY SCALE; INTRAMEDULLARY NAILING; LYSHOLM SCORE; MAJOR CLINICAL STUDY; MALE; NOYES SCORE; PATELLA; PATIENT SATISFACTION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; QUADRICEPS TENDON AUTOGRAFT; SCREW FIXATION; STATISTICAL SIGNIFICANCE; TENDON GRAFT;

EID: 36249012499     PISSN: 03635465     EISSN: 15523365     Source Type: Journal    
DOI: 10.1177/0363546507307390     Document Type: Article
Times cited : (27)

References (25)
  • 1
    • 0022912504 scopus 로고
    • The phenomenon of "ligamentization": Anterior cruciate ligament reconstruction with autogenous patellar tendon
    • Amiel D., Kleiner JB, Roux RD, Harwood FL, Akeson WH The phenomenon of "ligamentization": anterior cruciate ligament reconstruction with autogenous patellar tendon. J Orthop Res. 1986 ; 4: 162-172.
    • (1986) J Orthop Res , vol.4 , pp. 162-172
    • Amiel, D.1    Kleiner, J.B.2    Roux, R.D.3    Harwood, F.L.4    Akeson, W.H.5
  • 2
    • 22144452115 scopus 로고    scopus 로고
    • Arthroscopic anterior cruciate ligament reconstruction using quadriceps tendon autograft and bioabsorbable cross-pin fixation
    • Antonogiannakis E., Yiannakopoulos CK, Hiotis I., Karabalis C., Babalis G. Arthroscopic anterior cruciate ligament reconstruction using quadriceps tendon autograft and bioabsorbable cross-pin fixation. Arthroscopy. 2005 ; 21: 894.
    • (2005) Arthroscopy , vol.21 , pp. 894
    • Antonogiannakis, E.1    Yiannakopoulos, C.K.2    Hiotis, I.3    Karabalis, C.4    Babalis, G.5
  • 4
    • 0029704488 scopus 로고    scopus 로고
    • The tendon defect after anterior cruciate ligament reconstruction using the midthird patellar tendon: A problem for the patellofemoral joint?
    • Breitfuss H., Frohlich R., Povacz P., Resch H., Wicker A. The tendon defect after anterior cruciate ligament reconstruction using the midthird patellar tendon: a problem for the patellofemoral joint? Knee Surg Sports Traumatol Arthrosc. 1996 ; 3: 194-198.
    • (1996) Knee Surg Sports Traumatol Arthrosc , vol.3 , pp. 194-198
    • Breitfuss, H.1    Frohlich, R.2    Povacz, P.3    Resch, H.4    Wicker, A.5
  • 5
    • 0028219546 scopus 로고
    • Patellar tendon length after anterior cruciate ligament reconstruction
    • Dandy DJ, Desai SS Patellar tendon length after anterior cruciate ligament reconstruction. J Bone Joint Surg Br. 1994 ; 76: 198-199.
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 198-199
    • Dandy, D.J.1    Desai, S.S.2
  • 6
    • 0037240306 scopus 로고    scopus 로고
    • Patellar tendon or semitendinosus tendon autografts for anterior cruciate ligament reconstruction? a prospective randomized study with a two-year follow-up
    • Ejerhed L., Kartus J., Sernert N., Kohler K., Karlsson J. Patellar tendon or semitendinosus tendon autografts for anterior cruciate ligament reconstruction? A prospective randomized study with a two-year follow-up. Am J Sports Med. 2003 ; 31: 19-25.
    • (2003) Am J Sports Med. , vol.31 , pp. 19-25
    • Ejerhed, L.1    Kartus, J.2    Sernert, N.3    Kohler, K.4    Karlsson, J.5
  • 7
    • 0012459312 scopus 로고
    • Arthroscopic allograft anterior cruciate ligament reconstruction
    • Fu FH, Miller MD Arthroscopic allograft anterior cruciate ligament reconstruction. Oper Tech Sports Med. 1995 ; 3: 148-156.
    • (1995) Oper Tech Sports Med. , vol.3 , pp. 148-156
    • Fu, F.H.1    Miller, M.D.2
  • 8
    • 27544471365 scopus 로고    scopus 로고
    • Broken bioabsorbable femoral cross-pin after anterior cruciate ligament reconstruction with hamstring tendon graft
    • Han I., Yeon HK, Jae HY, Sang CS, Tae KK Broken bioabsorbable femoral cross-pin after anterior cruciate ligament reconstruction with hamstring tendon graft. Am J Sports Med. 2005 ; 33: 1742-1745.
    • (2005) Am J Sports Med. , vol.33 , pp. 1742-1745
    • Han, I.1    Yeon, H.K.2    Jae, H.Y.3    Sang, C.S.4    Tae, K.K.5
  • 9
    • 0031617555 scopus 로고    scopus 로고
    • Use of the International Knee Documentation Committee guidelines to assess outcome following anterior cruciate ligament reconstruction
    • Irrgang JJ, Ho H., Harner CD, Fu FH Use of the International Knee Documentation Committee guidelines to assess outcome following anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 1998 ; 6: 107-114.
    • (1998) Knee Surg Sports Traumatol Arthrosc. , vol.6 , pp. 107-114
    • Irrgang, J.J.1    Ho, H.2    Harner, C.D.3    Fu, F.H.4
  • 10
    • 0037243830 scopus 로고    scopus 로고
    • A prospective randomized study of patellar versus hamstring tendon autografts for anterior cruciate ligament reconstruction
    • Jansson KA, Linko E., Sandelin J., Harilainen A. A prospective randomized study of patellar versus hamstring tendon autografts for anterior cruciate ligament reconstruction. Am J Sports Med. 2003 ; 31: 12-18.
    • (2003) Am J Sports Med. , vol.31 , pp. 12-18
    • Jansson, K.A.1    Linko, E.2    Sandelin, J.3    Harilainen, A.4
  • 11
    • 0032611953 scopus 로고    scopus 로고
    • Complications following arthroscopic anterior cruciate ligament reconstruction: A 2-5-year follow-up of 604 patients with special emphasis on anterior knee pain
    • Kartus J., Magnusson L., Stener S., et al. Complications following arthroscopic anterior cruciate ligament reconstruction: a 2-5-year follow-up of 604 patients with special emphasis on anterior knee pain. Knee Surg Sports Traumatol Arthrosc. 1999 ; 7: 2-8.
    • (1999) Knee Surg Sports Traumatol Arthrosc , vol.7 , pp. 2-8
    • Kartus, J.1    Magnusson, L.2    Stener, S.3
  • 12
    • 0035526460 scopus 로고    scopus 로고
    • Donor-site morbidity and anterior knee problems after anterior cruciate ligament reconstruction using autografts
    • Kartus J., Movin T., Karlsson J. Donor-site morbidity and anterior knee problems after anterior cruciate ligament reconstruction using autografts. Arthroscopy. 2001 ; 17: 971-980.
    • (2001) Arthroscopy , vol.17 , pp. 971-980
    • Kartus, J.1    Movin, T.2    Karlsson, J.3
  • 13
    • 85047694593 scopus 로고    scopus 로고
    • Outcome of anterior cruciate ligament reconstruction using quadriceps tendon autograft
    • Lee S., Seong SC, Jo H., Park YK, Lee MC Outcome of anterior cruciate ligament reconstruction using quadriceps tendon autograft. Arthroscopy. 2004 ; 20: 795-802.
    • (2004) Arthroscopy , vol.20 , pp. 795-802
    • Lee, S.1    Seong, S.C.2    Jo, H.3    Park, Y.K.4    Lee, M.C.5
  • 14
    • 0020309029 scopus 로고
    • Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale
    • Lysholm J., Gillquist J. Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale. Am J Sports Med. 1982 ; 10: 150-154.
    • (1982) Am J Sports Med. , vol.10 , pp. 150-154
    • Lysholm, J.1    Gillquist, J.2
  • 15
    • 1242343973 scopus 로고    scopus 로고
    • Hamstring anterior cruciate ligament reconstruction: A comparison of bioabsorbable interference screw and endobutton-post fixation
    • Ma CB, Francis K., Towers J., Irrgang J., Fu FH, Harner CH Hamstring anterior cruciate ligament reconstruction: a comparison of bioabsorbable interference screw and endobutton-post fixation. Arthroscopy. 2004 ; 20: 122-128.
    • (2004) Arthroscopy , vol.20 , pp. 122-128
    • Ma, C.B.1    Francis, K.2    Towers, J.3    Irrgang, J.4    Fu, F.H.5    Ch, H.6
  • 16
    • 1542406074 scopus 로고    scopus 로고
    • MRI in ACL reconstructive surgery with PDLLA bioabsorbable interference screws: Evaluation of degradation and osteointegration processes of bioabsorbable screws [in Italian]
    • Macarini L., Murrone M., Marini S., Mocci A., Ettorre GC MRI in ACL reconstructive surgery with PDLLA bioabsorbable interference screws: evaluation of degradation and osteointegration processes of bioabsorbable screws [in Italian]. Radiol Med (Torino). 2004 ; 107: 47-57.
    • (2004) Radiol Med (Torino). , vol.107 , pp. 47-57
    • MacArini, L.1    Murrone, M.2    Marini, S.3    Mocci, A.4    Ettorre, G.C.5
  • 17
    • 33745683656 scopus 로고    scopus 로고
    • Reconstruction of the anterior cruciate ligament using bone-patellar tendon-bone graft with double biodegradable femoral pin fixation
    • Mahirogullari M., Oguz Y., Ozkan H. Reconstruction of the anterior cruciate ligament using bone-patellar tendon-bone graft with double biodegradable femoral pin fixation. Knee Surg Sports Traumatol Arthrosc. 2006 ; 13: 1-8.
    • (2006) Knee Surg Sports Traumatol Arthrosc , vol.13 , pp. 1-8
    • Mahirogullari, M.1    Oguz, Y.2    Ozkan, H.3
  • 18
    • 0033049022 scopus 로고    scopus 로고
    • Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
    • McGuire DA, Barber FA, Elrod BF, Paulos LE Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy. 1999 ; 15: 463-473.
    • (1999) Arthroscopy , vol.15 , pp. 463-473
    • McGuire, D.A.1    Barber, F.A.2    Elrod, B.F.3    Le, P.4
  • 19
    • 0028124307 scopus 로고
    • Use of allografts after failed treatment of rupture of the anterior cruciate ligament
    • Noyes FR, Barber-Westin SD, Roberts CS Use of allografts after failed treatment of rupture of the anterior cruciate ligament. J Bone Joint Surg Am. 1994 ; 76: 1019-1031.
    • (1994) J Bone Joint Surg Am. , vol.76 , pp. 1019-1031
    • Noyes, F.R.1    Barber-Westin, S.D.2    Roberts, C.S.3
  • 21
    • 0027461667 scopus 로고
    • Deterioration of patellofemoral articular surfaces after anterior cruciate ligament reconstruction
    • Shino K., Nakagawa S., Inoue M., Horibe S., Yoneda M. Deterioration of patellofemoral articular surfaces after anterior cruciate ligament reconstruction. Am J Sports Med. 1993 ; 21: 206-211.
    • (1993) Am J Sports Med. , vol.21 , pp. 206-211
    • Shino, K.1    Nakagawa, S.2    Inoue, M.3    Horibe, S.4    Yoneda, M.5
  • 22
    • 0036488211 scopus 로고    scopus 로고
    • Tendon healing in a bone tunnel, part II: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep
    • Weiler A., Hoffmann RF, Bail HJ, Rehm O., Sudkamp NP Tendon healing in a bone tunnel, part II: histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep. Arthroscopy. 2002 ; 18: 124-135.
    • (2002) Arthroscopy , vol.18 , pp. 124-135
    • Weiler, A.1    Hoffmann, R.F.2    Bail, H.J.3    Rehm, O.4    Sudkamp, N.P.5
  • 24
    • 23244450983 scopus 로고    scopus 로고
    • Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts
    • Zantop T., Ruemmler M., Welbers B., Langer M., Weimann A., Petersen W. Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts. Arthroscopy. 2005 ; 21: 934-941.
    • (2005) Arthroscopy , vol.21 , pp. 934-941
    • Zantop, T.1    Ruemmler, M.2    Welbers, B.3    Langer, M.4    Weimann, A.5    Petersen, W.6
  • 25
    • 12444310119 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new cross-pin technique for the fixation of different sized bone-patellar tendon-bone grafts
    • Zantop T., Welbers B., Weimann A., et al. Biomechanical evaluation of a new cross-pin technique for the fixation of different sized bone-patellar tendon-bone grafts. Knee Surg Sports Traumatol Arthrosc. 2004 ; 12: 520-527.
    • (2004) Knee Surg Sports Traumatol Arthrosc , vol.12 , pp. 520-527
    • Zantop, T.1    Welbers, B.2    Weimann, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.