메뉴 건너뛰기




Volumn 107, Issue 1-2, 2004, Pages 47-57

MRI in ACL reconstructive surgery with PDLLA bioabsorbable interference screws: Evaluation of degradation and osteointegration processes of bioabsorbable screws;La RM negli interventi di ricostruzione del LCA con viti ad interferenza bioriassorbibili in PDLLA: Valutazione dei processi di degradazione ed osteointegrazione delle viti bioriassorbibili

Author keywords

Anterior cruciate ligament; Bioabsorbable interference screws; Knee; MR

Indexed keywords

POLYLACTIC ACID;

EID: 1542406074     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (44)

References (36)
  • 1
    • 0028062715 scopus 로고
    • Arthroscopy assisted anterior cruciate ligament reconstruction using patellar tendon substitution. Two to four years follow-up results
    • Bach BR, Jones GT, Swett FA et al: Arthroscopy assisted anterior cruciate ligament reconstruction using patellar tendon substitution. Two to four years follow-up results. Am J Sports Med 22: 758-767, 1994.
    • (1994) Am J Sports Med , vol.22 , pp. 758-767
    • Bach, B.R.1    Jones, G.T.2    Swett, F.A.3
  • 2
    • 0025695615 scopus 로고
    • A prospective randomised study of three surgical techniques for treatment of acute ruptures of the anterior cruciate ligament
    • Engebretsen L, Benum P, Fasting O et al: A prospective randomised study of three surgical techniques for treatment of acute ruptures of the anterior cruciate ligament. Am J Sports Med 18: 585-590, 1990.
    • (1990) Am J Sports Med , vol.18 , pp. 585-590
    • Engebretsen, L.1    Benum, P.2    Fasting, O.3
  • 4
    • 0022738051 scopus 로고
    • Biodegradable bone repair materials: Synthetic polymers and ceramics
    • Hollinger JO, Battistone GC: Biodegradable bone repair materials: synthetic polymers and ceramics. Clin Orthop 207: 290-305, 1986.
    • (1986) Clin Orthop , vol.207 , pp. 290-305
    • Hollinger, J.O.1    Battistone, G.C.2
  • 5
    • 0031885152 scopus 로고    scopus 로고
    • Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws
    • Weiler A, Windhagen HJ, Raschke MJ et al: Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26: 119-128, 1998.
    • (1998) Am J Sports Med , vol.26 , pp. 119-128
    • Weiler, A.1    Windhagen, H.J.2    Raschke, M.J.3
  • 6
    • 0032588699 scopus 로고    scopus 로고
    • Ligament graft initial fixation strength using biodegradable interference screws
    • Rupp S, Seil R, Schneider A et al: Ligament graft initial fixation strength using biodegradable interference screws. J Biomed Mater Res 48: 74-79, 1999.
    • (1999) J Biomed Mater Res , vol.48 , pp. 74-79
    • Rupp, S.1    Seil, R.2    Schneider, A.3
  • 7
    • 0031730815 scopus 로고    scopus 로고
    • Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model
    • Seil R, Rupp S, Krauss PW et al: Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26: 815-19, 1998.
    • (1998) Am J Sports Med , vol.26 , pp. 815-819
    • Seil, R.1    Rupp, S.2    Krauss, P.W.3
  • 8
    • 0036828516 scopus 로고    scopus 로고
    • Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up
    • Bach FD, Carlier RY, Elis JB et al: Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up. Radiology 225: 541-550, 2002.
    • (2002) Radiology , vol.225 , pp. 541-550
    • Bach, F.D.1    Carlier, R.Y.2    Elis, J.B.3
  • 9
    • 0032827120 scopus 로고    scopus 로고
    • Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction
    • Lajtai G, Noszian I, Humer K et al: Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction. Arthroscopy 15: 709-718, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 709-718
    • Lajtai, G.1    Noszian, I.2    Humer, K.3
  • 10
    • 0033062398 scopus 로고    scopus 로고
    • Serial magnetic resonance imaging evaluation of a bioabsorbable interference screw and the adiacent bone
    • Lajtai G, Humer K, Aitzetmuller G et al: Serial magnetic resonance imaging evaluation of a bioabsorbable interference screw and the adiacent bone. Arthroscopy 15: 481-488, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 481-488
    • Lajtai, G.1    Humer, K.2    Aitzetmuller, G.3
  • 11
    • 0033023293 scopus 로고    scopus 로고
    • Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction
    • Warden WH, Friedman R, Teresi LM et al: Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction. Arthroscopy 15: 474-480, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 474-480
    • Warden, W.H.1    Friedman, R.2    Teresi, L.M.3
  • 12
    • 0034234476 scopus 로고    scopus 로고
    • Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: A prospective tomography controlled study
    • Fink C, Benedetto KP, Hackl W et al: Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: a prospective tomography controlled study. Arthroscopy 16: 491-498, 2000.
    • (2000) Arthroscopy , vol.16 , pp. 491-498
    • Fink, C.1    Benedetto, K.P.2    Hackl, W.3
  • 13
    • 2242440040 scopus 로고    scopus 로고
    • Nuovo sistema di fissazione femorale dei trapianti tendinei pro LCA. Esperienza preliminare con RM
    • Belleli A, Adriani E, Avitto A et al: Nuovo sistema di fissazione femorale dei trapianti tendinei pro LCA. Esperienza preliminare con RM. Radiol Med 102: 211-216, 2001.
    • (2001) Radiol Med , vol.102 , pp. 211-216
    • Belleli, A.1    Adriani, E.2    Avitto, A.3
  • 14
    • 0035413031 scopus 로고    scopus 로고
    • Bone tunnel remodelling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction
    • Lajtai G, Schiedhuber G, Unger F et al: Bone tunnel remodelling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction. Arthroscopy 17: 597-602, 2001.
    • (2001) Arthroscopy , vol.17 , pp. 597-602
    • Lajtai, G.1    Schiedhuber, G.2    Unger, F.3
  • 15
    • 1542433331 scopus 로고    scopus 로고
    • Initial fixation strength of polylactic acid interference screws in anterior cruciate ligament reconstruction
    • Abate JA, Fadale PD, Hulstyn MJ et al: Initial fixation strength of polylactic acid interference screws in anterior cruciate ligament reconstruction. Arthroscopy 11: 537-48, 1998.
    • (1998) Arthroscopy , vol.11 , pp. 537-548
    • Abate, J.A.1    Fadale, P.D.2    Hulstyn, M.J.3
  • 16
    • 0028786512 scopus 로고
    • Preliminary results of an absorbable interference screw
    • Barber FA, Elrod BF, McGuire DA et al: Preliminary results of an absorbable interference screw. Arthroscopy 11: 537-548, 1995.
    • (1995) Arthroscopy , vol.11 , pp. 537-548
    • Barber, F.A.1    Elrod, B.F.2    McGuire, D.A.3
  • 17
    • 0033049022 scopus 로고    scopus 로고
    • Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
    • McGuire DA, Barber FA, Elrod BF et al: Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 15: 463-473, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 463-473
    • McGuire, D.A.1    Barber, F.A.2    Elrod, B.F.3
  • 18
    • 0029809879 scopus 로고    scopus 로고
    • Metal and biodegradable interference screws: Comparison of failure strength
    • Johnson LL, Van Dyk GE: Metal and biodegradable interference screws: comparison of failure strength. Arthroscopy 12: 452-456, 1996.
    • (1996) Arthroscopy , vol.12 , pp. 452-456
    • Johnson, L.L.1    Van Dyk, G.E.2
  • 19
    • 0026836448 scopus 로고
    • MR imaging and metallic implants for anterior cruciate ligament reconstruction: Assessment of ferromagnetism and artifact
    • Shellock FG, Mink JH, Curtin S et al: MR imaging and metallic implants for anterior cruciate ligament reconstruction: assessment of ferromagnetism and artifact. J Magn Reson Imaging 2: 225-228, 1992.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 225-228
    • Shellock, F.G.1    Mink, J.H.2    Curtin, S.3
  • 20
    • 0027551945 scopus 로고
    • The value of MRI in the evaluation of the ACL deficient knee and in the post-operative evaluation after ACL reconstruction
    • Sanchis Alfonso V, Martinez-Sanjuan V, Gastaldi-Orquin E: The value of MRI in the evaluation of the ACL deficient knee and in the post-operative evaluation after ACL reconstruction. Eur J Radiol 16: 126-130, 1993.
    • (1993) Eur J Radiol , vol.16 , pp. 126-130
    • Sanchis Alfonso, V.1    Martinez-Sanjuan, V.2    Gastaldi-Orquin, E.3
  • 21
    • 0027244311 scopus 로고
    • Evaluation of arthroscopic anterior cruciate ligament reconstruction using magnetic resonance imaging
    • Maywood RM, Murphy BJ, Uribe JW et al: Evaluation of arthroscopic anterior cruciate ligament reconstruction using magnetic resonance imaging. Am J Sports Med 21: 523-527, 1993.
    • (1993) Am J Sports Med , vol.21 , pp. 523-527
    • Maywood, R.M.1    Murphy, B.J.2    Uribe, J.W.3
  • 22
    • 0026057423 scopus 로고
    • Anterior cruciate ligament reconstruction: Evaluation with MR Imaging
    • Rak KM, Gillogly SD, Schaefer RA et al: Anterior cruciate ligament reconstruction: evaluation with MR Imaging. Radiology 178: 553-556, 1991.
    • (1991) Radiology , vol.178 , pp. 553-556
    • Rak, K.M.1    Gillogly, S.D.2    Schaefer, R.A.3
  • 24
    • 0023280269 scopus 로고
    • A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction
    • Kurosaka M, Yoshiya S, Andrish JT: A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 15: 225-229, 1987.
    • (1987) Am J Sports Med , vol.15 , pp. 225-229
    • Kurosaka, M.1    Yoshiya, S.2    Andrish, J.T.3
  • 25
    • 0020656022 scopus 로고
    • Vascularized patellar tendon graft with rigid internal fixation for anterior cruciate ligament insufficiency
    • Lambert KL: Vascularized patellar tendon graft with rigid internal fixation for anterior cruciate ligament insufficiency. Clin Orthop 172: 85-90, 1994.
    • (1994) Clin Orthop , vol.172 , pp. 85-90
    • Lambert, K.L.1
  • 26
    • 0034921039 scopus 로고    scopus 로고
    • Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction
    • Kousa P, Jarvinen TL, Kannus P et al: Initial fixation strength of bioabsorbable and titanium interference screws in anterior cruciate ligament reconstruction. Arthroscopy 29: 420-425, 2001.
    • (2001) Arthroscopy , vol.29 , pp. 420-425
    • Kousa, P.1    Jarvinen, T.L.2    Kannus, P.3
  • 27
    • 0031302303 scopus 로고    scopus 로고
    • Metallic versus bioabsorbable interference screw for fixation of bone-patellar tendon-bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report
    • Marti C, Imhoff AB, Bahrs C et al: Metallic versus bioabsorbable interference screw for fixation of bone-patellar tendon-bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc 5: 217-221, 1997.
    • (1997) Knee Surg Sports Traumatol Arthrosc , vol.5 , pp. 217-221
    • Marti, C.1    Imhoff, A.B.2    Bahrs, C.3
  • 28
    • 0003184452 scopus 로고
    • Clinical experience using a bioabsorbable interference screw for ACL reconstruction
    • Stahelin AC, Feinstein R, Friedrich NF: Clinical experience using a bioabsorbable interference screw for ACL reconstruction. Orthop Trans 19: 287-288, 1995.
    • (1995) Orthop Trans , vol.19 , pp. 287-288
    • Stahelin, A.C.1    Feinstein, R.2    Friedrich, N.F.3
  • 29
    • 0032734022 scopus 로고    scopus 로고
    • Absorbable and metal interference screws: Comparison of graft security during healing
    • Walton M: Absorbable and metal interference screws: comparison of graft security during healing. Arthroscopy 15: 818-26, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 818-826
    • Walton, M.1
  • 30
    • 53949109215 scopus 로고    scopus 로고
    • Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 25 years in vivo
    • Morgan CD, Gehrmann RM, Jayo MJ et al: Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 25 years in vivo. Arthroscopy 18, 2002.
    • (2002) Arthroscopy , pp. 18
    • Morgan, C.D.1    Gehrmann, R.M.2    Jayo, M.J.3
  • 31
    • 0026518970 scopus 로고
    • Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures
    • Bostman OM: Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin Orthop 278: 193-199, 1992.
    • (1992) Clin Orthop , vol.278 , pp. 193-199
    • Bostman, O.M.1
  • 32
    • 0026583096 scopus 로고
    • Foreign body reactions to polyglycolide screws
    • Bostman O, Partio E, Hirvensalo E et al: Foreign body reactions to polyglycolide screws. Acta Orthop Scand 63: 173-176, 1992.
    • (1992) Acta Orthop Scand , vol.63 , pp. 173-176
    • Bostman, O.1    Partio, E.2    Hirvensalo, E.3
  • 33
    • 0030903593 scopus 로고    scopus 로고
    • Clinical degradation and biocompatibility of different bioabsorbable interference screws: A report six cases
    • Stahelin AC, Weiler A, Rufencht H et al: Clinical degradation and biocompatibility of different bioabsorbable interference screws: a report six cases. Arthroscopy 13: 238-244, 1997.
    • (1997) Arthroscopy , vol.13 , pp. 238-244
    • Stahelin, A.C.1    Weiler, A.2    Rufencht, H.3
  • 34
    • 0032957063 scopus 로고    scopus 로고
    • Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screws fixation
    • Martinek V, Friederich NF: Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screws fixation. Arthroscopy 15: 317-320, 1999.
    • (1999) Arthroscopy , vol.15 , pp. 317-320
    • Martinek, V.1    Friederich, N.F.2
  • 35
    • 0031957076 scopus 로고    scopus 로고
    • Pretibial cyst formation after anterior cruciate ligament surgery with soft tissue autografts
    • Simonian PT, Wickiewicz TL, O'Brien SJ et al: Pretibial cyst formation after anterior cruciate ligament surgery with soft tissue autografts. Arthroscopy 14: 215-220, 1998.
    • (1998) Arthroscopy , vol.14 , pp. 215-220
    • Simonian, P.T.1    Wickiewicz, T.L.2    O'Brien, S.J.3
  • 36
    • 0035526456 scopus 로고    scopus 로고
    • A post mortem examination of poly-L lactid interference screw 4 months after implantation during anterior cruciate ligament reconstruction
    • McGuire DA, barber FA, Milchgrub S et al: A post mortem examination of poly-L lactid interference screw 4 months after implantation during anterior cruciate ligament reconstruction. Arthroscopy 17: 988-992, 2001.
    • (2001) Arthroscopy , vol.17 , pp. 988-992
    • McGuire, D.A.1    Barber, F.A.2    Milchgrub, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.