메뉴 건너뛰기




Volumn 30, Issue 5, 2006, Pages 320-324

Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE NAIL; BONE PLATE; BONE SCREW; COMPARATIVE STUDY; FEMALE; FEMUR NECK FRACTURE; HUMAN; INTRAMEDULLARY NAILING; MALE; METHODOLOGY; RADIOGRAPHY;

EID: 36049049092     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-006-0092-0     Document Type: Article
Times cited : (8)

References (5)
  • 1
    • 0041321380 scopus 로고    scopus 로고
    • Implant-related complications in the treatment of unstable intertrochanteric fractures: Meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices
    • DOI 10.1007/s00264-003-0457-6
    • Audige L, Hanson B, Swiontkowski MF (2003) Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic hip screw plate versus dynamic screw-intramedullary devices. Int Orthop 27(4):197-203 (Pubitemid 37070874)
    • (2003) International Orthopaedics , vol.27 , Issue.4 , pp. 197-203
    • Audige, L.1    Hanson, B.2    Swiontkowski, M.F.3
  • 2
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77(7):1058-1064
    • (1995) J Bone Joint Surg Am , vol.77 , Issue.7 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3    Keggi, J.M.4
  • 3
    • 0031925810 scopus 로고    scopus 로고
    • Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail
    • DOI 10.1016/S0020-1383(97)00158-7, PII S0020138397001587
    • Kawaguchi S, Sawada K, Nabeta Y (1998) Cutting out of the lag screw after internal fixation with the Asiatic gamma nail. Injury 29(1):47-53 (Pubitemid 28205962)
    • (1998) Injury , vol.29 , Issue.1 , pp. 47-53
    • Kawaguchi, S.1    Sawada, K.2    Nabeta, Y.3
  • 4
    • 0026764040 scopus 로고
    • Cutting-out of the dynamic hip screw related to its position
    • Parker MJ (1992) Cutting-out of the dynamic hip screw related to its position. J Bone Joint Surg Br 74(4):625
    • (1992) J Bone Joint Surg Br , vol.74 , Issue.4 , pp. 625
    • Parker, M.J.1
  • 5
    • 4444241897 scopus 로고    scopus 로고
    • Prediction of fixation failure after sliding hip screw fixation
    • DOI 10.1016/j.injury.2003.10.028, PII S0020138303004674
    • Pervez H, Parker MJ, Vowler S (2004) Prediction of fixation failure after sliding hip screw fixation. Injury 35:994-998 (Pubitemid 39194767)
    • (2004) Injury , vol.35 , Issue.10 , pp. 994-998
    • Pervez, H.1    Parker, M.J.2    Vowler, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.