메뉴 건너뛰기




Volumn 52, Issue 22, 2007, Pages

Real-time tracking of tumor motions and deformations along the leaf travel direction with the aid of a synchronized dynamic MLC leaf sequencer

Author keywords

[No Author keywords available]

Indexed keywords

DEFORMATION; DRUG DELIVERY; OPTIMIZATION; PLANTS (BOTANY); RADIOTHERAPY; REAL TIME CONTROL; SYNCHRONIZATION; TUMORS;

EID: 35848929285     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/52/22/N01     Document Type: Article
Times cited : (46)

References (20)
  • 1
    • 0038710316 scopus 로고    scopus 로고
    • Segmental and dynamic intensity-modulated radiotherapy delivery techniques for micro-multileaf collimator
    • Agazaryan N and Solberg T D 2003 Segmental and dynamic intensity-modulated radiotherapy delivery techniques for micro-multileaf collimator Med. Phys. 30 1758-67
    • (2003) Med. Phys. , vol.30 , Issue.7 , pp. 1758-1767
    • Agazaryan, N.1    Solberg, T.D.2
  • 2
  • 4
    • 1142275392 scopus 로고    scopus 로고
    • Optimal leaf sequencing with elimination of tongue-and-groove underdosage
    • Kamath S, Sahni S, Palta J, Ranka S and Li J 2004 Optimal leaf sequencing with elimination of tongue-and-groove underdosage Phys. Med. Biol. 49 N7-19
    • (2004) Phys. Med. Biol. , vol.49 , Issue.3 , pp. 7-19
    • Kamath, S.1    Sahni, S.2    Palta, J.3    Ranka, S.4    Li, J.5
  • 5
    • 33646481945 scopus 로고    scopus 로고
    • An improved MLC segmentation algorithm and software for step-and-shoot IMRT delivery without tongue-and-groove error
    • Luan S, Wang C, Chen D Z, Hu X S, Naqvi S A, Wu X and Yu C X 2006 An improved MLC segmentation algorithm and software for step-and-shoot IMRT delivery without tongue-and-groove error Med. Phys. 33 1199-212
    • (2006) Med. Phys. , vol.33 , Issue.5 , pp. 1199-1212
    • Luan, S.1    Wang, C.2    Chen, D.Z.3    Hu, X.S.4    Naqvi, S.A.5    Wu, X.6    Yu, C.X.7
  • 6
    • 33646005165 scopus 로고    scopus 로고
    • Simulation and visualization of dose uncertainties due to interfractional organ motion
    • Maleike D, Unkelbach J and Oelfke U 2006 Simulation and visualization of dose uncertainties due to interfractional organ motion Phys. Med. Biol. 51 2237-52
    • (2006) Phys. Med. Biol. , vol.51 , Issue.9 , pp. 2237-2252
    • Maleike, D.1    Unkelbach, J.2    Oelfke, U.3
  • 7
    • 33748537791 scopus 로고    scopus 로고
    • IMRT delivery to a moving target by dynamic MLC tracking: Delivery for targets moving in two dimensions in the beam's eye view
    • McQuaid D and Webb S 2006 IMRT delivery to a moving target by dynamic MLC tracking: delivery for targets moving in two dimensions in the beam's eye view Phys. Med. Biol. 51 4819-39
    • (2006) Phys. Med. Biol. , vol.51 , Issue.19 , pp. 4819-4839
    • McQuaid, D.1    Webb, S.2
  • 8
    • 12844267410 scopus 로고    scopus 로고
    • DMLC leaf-pair optimal control for mobile, deforming target
    • Papiez L and Rangaraj D 2005 DMLC leaf-pair optimal control for mobile, deforming target Med. Phys. 32 275-85
    • (2005) Med. Phys. , vol.32 , Issue.1 , pp. 275-285
    • Papiez, L.1    Rangaraj, D.2
  • 9
    • 25644438567 scopus 로고    scopus 로고
    • Real-time DMLC IMRT delivery for mobile and deforming targets
    • Papiez L, Rangaraj D and Keall P J 2005 Real-time DMLC IMRT delivery for mobile and deforming targets Med. Phys. 32 3037-48
    • (2005) Med. Phys. , vol.32 , Issue.9 , pp. 3037-3048
    • Papiez, L.1    Rangaraj, D.2    Keall, P.J.3
  • 10
    • 21144443433 scopus 로고    scopus 로고
    • Synchronized delivery of DMLC intensity modulated radiation therapy for stationary and moving targets
    • Rangaraj D and Papiez L 2005 Synchronized delivery of DMLC intensity modulated radiation therapy for stationary and moving targets Med. Phys. 32 1802-17
    • (2005) Med. Phys. , vol.32 , Issue.6 , pp. 1802-1817
    • Rangaraj, D.1    Papiez, L.2
  • 12
    • 34347390456 scopus 로고    scopus 로고
    • Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study
    • Seppenwolde Y, Berbeco R I, Nishioka S, Shirato H and Heijmen B 2007 Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: a simulation study Med. Phys. 34 2774-84
    • (2007) Med. Phys. , vol.34 , Issue.7 , pp. 2774-2784
    • Seppenwolde, Y.1    Berbeco, R.I.2    Nishioka, S.3    Shirato, H.4    Heijmen, B.5
  • 14
    • 0028144837 scopus 로고
    • Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators
    • Spirou S V and Chui C S 1994 Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators Med. Phys. 24 1031-41
    • (1994) Med. Phys. , vol.21 , Issue.7 , pp. 1031-1041
    • Spirou, S.V.1    Chui, C.S.2
  • 16
    • 0028153801 scopus 로고
    • Analytical solution for the dynamic control of multileaf collimators
    • Svensson R, Källman P and Brahme A 1994 Analytical solution for the dynamic control of multileaf collimators Phys. Med. Biol. 39 37-61
    • (1994) Phys. Med. Biol. , vol.39 , Issue.1 , pp. 37-61
    • Svensson, R.1    Källman, P.2    Brahme, A.3
  • 17
    • 0029762999 scopus 로고    scopus 로고
    • Dynamic multileaf collimation without 'tongue-and-groove' underdosage effects
    • van Santvoort J P and Heijmen B J 1996 Dynamic multileaf collimation without 'tongue-and-groove' underdosage effects Phys. Med. Biol. 41 2091-105
    • (1996) Phys. Med. Biol. , vol.41 , Issue.10 , pp. 2091-2105
    • Van Santvoort, J.P.1    Heijmen, B.J.2
  • 19
    • 33748555520 scopus 로고    scopus 로고
    • A strategy to minimize errors from differential intrafraction organ motion using a single configuration for a 'breathing' multileaf collimator
    • Webb and Binnie 2006 A strategy to minimize errors from differential intrafraction organ motion using a single configuration for a 'breathing' multileaf collimator Phys. Med. Biol. 51 4517-31
    • (2006) Phys. Med. Biol. , vol.51 , Issue.18 , pp. 4517-4531
    • Webb1    Binnie2
  • 20
    • 0030888540 scopus 로고    scopus 로고
    • The effect of stair-step leaf transmission on the 'tongue-and-groove problem' in dynamic radiotherapy with a multileaf collimator
    • Webb S, Bortfeld T, Stein J and Convery D 1997 The effect of stair-step leaf transmission on the 'tongue-and-groove problem' in dynamic radiotherapy with a multileaf collimator Phys. Med. Biol. 42 595-602
    • (1997) Phys. Med. Biol. , vol.42 , Issue.3 , pp. 595-602
    • Webb, S.1    Bortfeld, T.2    Stein, J.3    Convery, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.