메뉴 건너뛰기




Volumn 34, Issue 11, 2007, Pages 4219-4222

Initial beam size study for passive scatter proton therapy. II. Changes in delivered depth dose profiles

Author keywords

Proton beam size; Proton therapy; Range modulation wheel; Spread out Bragg peak

Indexed keywords

BRAGG CELLS; MODULATION; NOZZLES; NUCLEAR INSTRUMENTATION; PROTON BEAMS;

EID: 35649018148     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2767934     Document Type: Article
Times cited : (6)

References (14)
  • 2
    • 0016626426 scopus 로고
    • Range modulators for protons and heavy ions
    • 0029-554X 10.1016/0029-554X(75)90430-9
    • A. M. Koehler, R. J. Schneider, and J. M. Sisterson, " Range modulators for protons and heavy ions., " Nucl. Instrum. Methods 0029-554X 10.1016/0029-554X(75)90430-9 131, 437-440 (1975).
    • (1975) Nucl. Instrum. Methods , vol.131 , pp. 437-440
    • Koehler, A.M.1    Schneider, R.J.2    Sisterson, J.M.3
  • 3
    • 0017722986 scopus 로고
    • Flattening of proton dose distributions for large-field radiotherapy
    • 0094-2405 10.1118/1.594317
    • A. M. Koehler, R. J. Schneider, and J. M. Sisterson, " Flattening of proton dose distributions for large-field radiotherapy., " Med. Phys. 0094-2405 10.1118/1.594317 4, 297-301 (1977).
    • (1977) Med. Phys. , vol.4 , pp. 297-301
    • Koehler, A.M.1    Schneider, R.J.2    Sisterson, J.M.3
  • 4
    • 17844399274 scopus 로고    scopus 로고
    • Monte Carlo simulation of a protontherapy platform devoted to ocular melanoma
    • 0094-2405 10.1118/1.1871392
    • J. Herault, N. Iborra, B. Serrano, and P. Chauvel, " Monte Carlo simulation of a protontherapy platform devoted to ocular melanoma., " Med. Phys. 0094-2405 10.1118/1.1871392 32, 910-919 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 910-919
    • Herault, J.1    Iborra, N.2    Serrano, B.3    Chauvel, P.4
  • 5
    • 0029049132 scopus 로고
    • Beam optics design of compact gantry for proton therapy
    • 0140-0118 10.1007/BF02510499
    • E. Pedroni and H. Enge, " Beam optics design of compact gantry for proton therapy., " Med. Biol. Eng. Comput. 0140-0118 10.1007/BF02510499 33, 271-277 (1995).
    • (1995) Med. Biol. Eng. Comput. , vol.33 , pp. 271-277
    • Pedroni, E.1    Enge, H.2
  • 6
    • 33644619566 scopus 로고    scopus 로고
    • Dose distributions of a proton beam for eye tumor therapy: Hybrid pencil-beam ray-tracing calculations
    • 0094-2405
    • C. Rethfeldt, H. Fuchs, and K. -U. Gardey, " Dose distributions of a proton beam for eye tumor therapy: Hybrid pencil-beam ray-tracing calculations., " Med. Phys. 33, 782-791 (2006). 0094-2405
    • (2006) Med. Phys. , vol.33 , pp. 782-791
    • Rethfeldt, C.1    Fuchs, H.2    Gardey, K.-U.3
  • 7
    • 0032440084 scopus 로고    scopus 로고
    • Monte Carlo method to study proton fluence for treatment planning
    • 0094-2405 10.1118/1.598447
    • H. Paganetti, " Monte Carlo method to study proton fluence for treatment planning., " Med. Phys. 0094-2405 10.1118/1.598447 25, 2370-2375 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2370-2375
    • Paganetti, H.1
  • 9
    • 33646459966 scopus 로고    scopus 로고
    • Optimization of current modulation function for proton spread-out Bragg peak fields
    • 0094-2405 10.1118/1.2188072
    • H. -M. Lu and H. Kooy, " Optimization of current modulation function for proton spread-out Bragg peak fields., " Med. Phys. 0094-2405 10.1118/1.2188072 33, 1281-1288 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 1281-1288
    • Lu, H.-M.1    Kooy, H.2
  • 10
    • 35648992463 scopus 로고    scopus 로고
    • Initial beam size study for passive scatter proton therapy. I. Monte Carlo verification
    • 0094-2405
    • J. C. Polf, M. C. Harvey, U. Titt, W. D. Newhauser, and A. R. Smith, " Initial beam size study for passive scatter proton therapy. I. Monte Carlo verification., " Med. Phys. 34, 4213-4218 (2007). 0094-2405
    • (2007) Med. Phys. , vol.34 , pp. 4213-4218
    • Polf, J.C.1    Harvey, M.C.2    Titt, U.3    Newhauser, W.D.4    Smith, A.R.5
  • 11
    • 85027229381 scopus 로고    scopus 로고
    • Los Alamos National Laboratory, MCNPX User's Manual, Version 2.4.0, LA-CP-02-408
    • Los Alamos National Laboratory, MCNPX User's Manual, Version 2.4.0, LA-CP-02-408, 2002.
    • (2002)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.