메뉴 건너뛰기




Volumn 23, Issue 6, 1996, Pages 939-951

Physical specifications of clinical proton beams from a synchrotron

Author keywords

physical performance specifications; proton beam spreading system; proton therapy; synchrotron

Indexed keywords

CHARGED PARTICLES; PROTON BEAMS; RADIOTHERAPY; SPECIFICATIONS; SYNCHROTRONS; TUMORS;

EID: 0029956044     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597735     Document Type: Article
Times cited : (22)

References (30)
  • 1
  • 10
    • 0041725879 scopus 로고
    • Initial operation of the LLUMC accelerator and beam transport
    • R. Little, "Initial operation of the LLUMC accelerator and beam transport," Nucl. Instrum. Meth. B 56/57, 1192 (1991).
    • (1991) Nucl. Instrum. Meth. B , vol.56-57 , pp. 1192
    • Little, R.1
  • 11
    • 0007161310 scopus 로고
    • Performance specifications for proton medical facility
    • March
    • W. T. Chu et al., "Performance specifications for proton medical facility," LBL 33749 (March 1993).
    • (1993) LBL , pp. 33749
    • Chu, W.T.1
  • 13
    • 85027236044 scopus 로고    scopus 로고
    • note
    • CEI Rule n 62-35, Medical electrical equipment. Part 2: Particular requirements for medical electrical accelerators in the range 1 MeV to 50 MeV. Section One: General. Section Two: Radiation safety for equipment (July 1991); CEI Rule n. 65-36, Medical electrical equipment - Medical electrical accelerators - Functional performance characteristics (July 1991).
  • 14
    • 3142605908 scopus 로고
    • State of the Art? New Proton medical facilities for the Massachusetts General Hospital and the University of California Davis Medical Center
    • K. P. Gall et al., "State of the Art? New Proton medical facilities for the Massachusetts General Hospital and the University of California Davis Medical Center," Nucl. Instr. Meth. B 79, 881 (1993); see also Massachusetts General Hospital and Lawrence Berkeley Laboratory, "Specifications for a Proton Therapy Research and Treatment Facility," NTPC-6 (April 1993).
    • (1993) Nucl. Instr. Meth. B , vol.79 , pp. 881
    • Gall, K.P.1
  • 15
    • 3142605908 scopus 로고
    • NTPC-6 April
    • K. P. Gall et al., "State of the Art? New Proton medical facilities for the Massachusetts General Hospital and the University of California Davis Medical Center," Nucl. Instr. Meth. B 79, 881 (1993); see also Massachusetts General Hospital and Lawrence Berkeley Laboratory, "Specifications for a Proton Therapy Research and Treatment Facility," NTPC-6 (April 1993).
    • (1993) Specifications for a Proton Therapy Research and Treatment Facility
  • 16
    • 85027238436 scopus 로고    scopus 로고
    • Ref. 5, Chap. 5
    • Ref. 5, Chap. 5.
  • 17
    • 33744704728 scopus 로고
    • Design of a raster scanning system for proton beams at the Italian Hadrontherapy facility
    • L. Sangaletti, "Design of a raster scanning system for proton beams at the Italian Hadrontherapy facility," Internal report TERA 94/28 FAS 6 (1994).
    • (1994) Internal Report TERA 94/28 FAS 6
    • Sangaletti, L.1
  • 27
    • 0242293048 scopus 로고
    • Entwicklung eines magnetischen Strahlführungssystems zur tumorkonformen Strahlentherapie mit schweren geladenen Teilchen
    • GSI-94-09
    • Th. Haberer, "Entwicklung eines magnetischen Strahlführungssystems zur tumorkonformen Strahlentherapie mit schweren geladenen Teilchen," GSI Report, GSI-94-09 (1994).
    • (1994) GSI Report
    • Haberer, T.1
  • 28
    • 0000277337 scopus 로고
    • Instrumentation for treatment of cancer using proton and light-ion beams
    • W. T. Chu, B. A. Ludewigt, and T. R. Renner, "Instrumentation for treatment of cancer using proton and light-ion beams," Rev. Sci. Instrum. 64, 2055 (1993).
    • (1993) Rev. Sci. Instrum. , vol.64 , pp. 2055
    • Chu, W.T.1    Ludewigt, B.A.2    Renner, T.R.3
  • 30
    • 0021466678 scopus 로고
    • A simple 'Vernier' method for improving the accuracy of coordinate read-out in large wire chambers
    • D. F. Anderson, H. K. Arvela, A. Breskin, and G Charpak, "A simple 'Vernier' method for improving the accuracy of coordinate read-out in large wire chambers," Nucl. Instrum. Meth. 224, 315 (1984).
    • (1984) Nucl. Instrum. Meth. , vol.224 , pp. 315
    • Anderson, D.F.1    Arvela, H.K.2    Breskin, A.3    Charpak, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.