메뉴 건너뛰기




Volumn 6532, Issue , 2007, Pages

Health monitoring with optical fiber sensors: From human body to civil structures

Author keywords

Distributed and quasi distributed sensors; Dynamic and static monitoring; Electromagnetic interference immunity; Elongation; Instrumented catheter; Miniature sensors; Pressure; Single point sensor; Strain; Temperature

Indexed keywords

ELECTROMAGNETIC WAVE INTERFERENCE; ELONGATION; MINIATURE INSTRUMENTS; OPTICAL FIBERS; OPTICAL SENSORS;

EID: 35649000897     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.715186     Document Type: Conference Paper
Times cited : (39)

References (37)
  • 2
    • 0004126078 scopus 로고
    • Instrument Society of America, Research Triangle Park, NC
    • nd Edition", Instrument Society of America, Research Triangle Park, NC (1992).
    • (1992) nd Edition
    • Krohn, D.A.1
  • 3
    • 0002885065 scopus 로고    scopus 로고
    • Fiber optic smart sensing
    • P. K. Rastogi editor, Artech House, pp
    • D. Inaudi "Fiber optic smart sensing" in "Optical Measurement techniques and applications", P. K. Rastogi editor, Artech House, pp. 255-275 (1997).
    • (1997) Optical Measurement techniques and applications , pp. 255-275
    • Inaudi, D.1
  • 4
    • 0003419046 scopus 로고
    • John Wiley & Sons, Wiley-Interscience, New-York
    • E. Udd in "Fiber optic smart structures", John Wiley & Sons, Wiley-Interscience, New-York (1995).
    • (1995) Fiber optic smart structures
    • Udd, E.1
  • 5
    • 0242588095 scopus 로고    scopus 로고
    • Photonic sensing technology in civil engineering applications
    • J. M. Lopez-Higuera editor, Wiley
    • D. Inaudi "Photonic sensing technology in civil engineering applications" in "Handbook of optical fibre sensing technology", J. M. Lopez-Higuera editor, Wiley (2002).
    • (2002) Handbook of optical fibre sensing technology
    • Inaudi, D.1
  • 7
    • 0037455676 scopus 로고    scopus 로고
    • Interferometric fiber-optic sensor embedded in spark plug for in-cylinder pressure measurement in engines
    • T. Bae et al. "Interferometric fiber-optic sensor embedded in spark plug for in-cylinder pressure measurement in engines", Appl. Opt, Vol. 42 (6), pp. 1003-1007 (2003).
    • (2003) Appl. Opt , vol.42 , Issue.6 , pp. 1003-1007
    • Bae, T.1
  • 8
    • 33646184807 scopus 로고    scopus 로고
    • Temperature and pressure fiber-optic sensors applied to minimally invasive diagnostics and therapies
    • San Jose, Ca, USA paper #6083-5
    • C. Hamel and É. Pinet "Temperature and pressure fiber-optic sensors applied to minimally invasive diagnostics and therapies", Proc. SPIE BiOS (San Jose, Ca, USA) paper #6083-5 (2006).
    • (2006) Proc. SPIE BiOS
    • Hamel, C.1    Pinet, E.2
  • 9
    • 0141944408 scopus 로고
    • Infrared optical loss increase in silica fibers due to hydrogen
    • N. Uchida and N. Uesugi "Infrared optical loss increase in silica fibers due to hydrogen", J. Lightw. Techn., Vol. LT-4 (8), pp. 1132-1138 (1986).
    • (1986) J. Lightw. Techn , vol.LT-4 , Issue.8 , pp. 1132-1138
    • Uchida, N.1    Uesugi, N.2
  • 10
    • 0025522139 scopus 로고    scopus 로고
    • A. lino et al. Mechanisms of hydrogen-induced losses in silica-based optical fibers, J. Lightw. Techn., 8 (11), pp. 1675-1678 (1990).
    • A. lino et al. "Mechanisms of hydrogen-induced losses in silica-based optical fibers", J. Lightw. Techn., Vol. 8 (11), pp. 1675-1678 (1990).
  • 11
    • 35649013463 scopus 로고    scopus 로고
    • Carbon coating reduces darkening
    • December 1, pp
    • J. Wallace "Carbon coating reduces darkening", Laser Focus World, December 1, pp 15-16 (2004).
    • (2004) Laser Focus World , pp. 15-16
    • Wallace, J.1
  • 12
    • 35649004603 scopus 로고    scopus 로고
    • th (2006).
    • th (2006).
  • 13
    • 35648967827 scopus 로고    scopus 로고
    • C Belleville and G, Duplain Fabry-Perot optical sensing device for measuring a physical parameter, US Patents #5,202,939 (1993) & #5,392,117 (1995).
    • C Belleville and G, Duplain "Fabry-Perot optical sensing device for measuring a physical parameter", US Patents #5,202,939 (1993) & #5,392,117 (1995).
  • 14
    • 28544437579 scopus 로고    scopus 로고
    • Miniature fiber-optic pressure sensor for medical applications: An opportunity for intra-aortic balloon pumping (IABP) therapy
    • Pinet É. et al. "Miniature fiber-optic pressure sensor for medical applications: an opportunity for intra-aortic balloon pumping (IABP) therapy", Proc. of SPIE, Vol. 5855, pp. 234-237 (2005).
    • (2005) Proc. of SPIE , vol.5855 , pp. 234-237
    • Pinet, E.1
  • 15
    • 0000739750 scopus 로고
    • Determination of structural parameters concerning load capacity based on fiber FabryPerot-interferometers
    • W. Habel and D. Hofmann "Determination of structural parameters concerning load capacity based on fiber FabryPerot-interferometers", Proc. SPIE, Vol. 2361, pp. 176-179 (1994).
    • (1994) Proc. SPIE , vol.2361 , pp. 176-179
    • Habel, W.1    Hofmann, D.2
  • 16
    • 84938361471 scopus 로고    scopus 로고
    • Application of Bragg grating sensors in Europe
    • th Int. conf. on OFS '97- Optical Fiber Sensors, Williamsbourg
    • th Int. conf. on OFS '97- Optical Fiber Sensors, Williamsbourg, OSA Technical Digest Series, Vol. 16, pp. 14-19 (1997).
    • (1997) OSA Technical Digest Series , vol.16 , pp. 14-19
    • Ferdinand, P.1
  • 17
    • 85136375588 scopus 로고    scopus 로고
    • Field testing and application of fiber optic displacement sensors in civil structures
    • th Int. conf. on OFS '97- Optical Fiber Sensors, Williamsbourg
    • th Int. conf. on OFS '97- Optical Fiber Sensors, Williamsbourg, OSA Technical Digest Series, Vol. 16, pp. 596-599 (1997).
    • (1997) OSA Technical Digest Series , vol.16 , pp. 596-599
    • Inaudi, D.1
  • 18
    • 0031342359 scopus 로고    scopus 로고
    • Embedded and surface mounted fiber optic sensors for civil structural monitoring, Smart Struct. & Mat. Conf, San Diego
    • D. Inaudi et al. "Embedded and surface mounted fiber optic sensors for civil structural monitoring", Smart Struct. & Mat. Conf, San Diego, SPIE Vol. 3044, pp. 236-243 (1997).
    • (1997) SPIE , vol.3044 , pp. 236-243
    • Inaudi, D.1
  • 19
    • 0001122529 scopus 로고    scopus 로고
    • Monitoring of large structure using distributed Brillouin fiber sensing
    • Kyongju, Korea
    • th Int. Conf. on Opt. Fiber Sens OFS-13., Kyongju, Korea, Vol. 3746, pp. 345-348 (1999).
    • (1999) th Int. Conf. on Opt. Fiber Sens OFS-13 , vol.3746 , pp. 345-348
    • Thévenaz, L.1
  • 20
    • 85076715152 scopus 로고
    • Simple Distributed temperature sensor based on Brillouin gain spectrum analysis
    • SPIE OFS-10, Glasgow, UK
    • th Int. Conf. on Opt. Fiber Sens., Glasgow, UK, Vol. 2360, pp. 138-141 (1994).
    • (1994) th Int. Conf. on Opt. Fiber Sens , vol.2360 , pp. 138-141
    • Niklès, M.1
  • 21
    • 6344222225 scopus 로고    scopus 로고
    • An improved model for the fully distributed temperature single-mode fibre optic sensor based on Raman optical frequency-domain reflectometry
    • J. Geng et al. "An improved model for the fully distributed temperature single-mode fibre optic sensor based on Raman optical frequency-domain reflectometry", J. Opt. A: Pure Appl. Opt., Vol. 6 (10), pp. 932-936 (2004).
    • (2004) J. Opt. A: Pure Appl. Opt , vol.6 , Issue.10 , pp. 932-936
    • Geng, J.1
  • 22
    • 34249694381 scopus 로고    scopus 로고
    • Sensors - Raman-based distributed temperature sensor with Simplex coding and link optimization
    • J. Park et al. "Sensors - Raman-based distributed temperature sensor with Simplex coding and link optimization", IEEE Photon. Technol. Lett, Vol. 18 (17-20), pp. 1879-1881 (2006).
    • (2006) IEEE Photon. Technol. Lett , vol.18 , Issue.17-20 , pp. 1879-1881
    • Park, J.1
  • 23
    • 0014406108 scopus 로고
    • Initial clinical experience with intra-aortic balloon pumping in cardiogenic shock
    • A. Kantrowitz et al. "Initial clinical experience with intra-aortic balloon pumping in cardiogenic shock", J. Am. Med. Assoc., Vol. 203(2), pp. 135-140 (1968).
    • (1968) J. Am. Med. Assoc , vol.203 , Issue.2 , pp. 135-140
    • Kantrowitz, A.1
  • 24
    • 0024234445 scopus 로고
    • The intra-aortic balloon pump: A review
    • G. A. Maccioli et al. "The intra-aortic balloon pump: a review", J. Cardiothoracic Anesthesia, Vol. 2(3), pp. 365-373 (1988).
    • (1988) J. Cardiothoracic Anesthesia , vol.2 , Issue.3 , pp. 365-373
    • Maccioli, G.A.1
  • 25
    • 0030943326 scopus 로고    scopus 로고
    • Intraaortic balloon pumping for cardiac support: Trends in practice and outcome, 1968 to 1995
    • D. F. Torchiana et al "Intraaortic balloon pumping for cardiac support: trends in practice and outcome, 1968 to 1995", J. Thor. Cardio. Surg., Vol. 113(4), pp. 758-769 (1997).
    • (1997) J. Thor. Cardio. Surg , vol.113 , Issue.4 , pp. 758-769
    • Torchiana, D.F.1
  • 26
    • 0019523842 scopus 로고
    • Direct blood pressure measurement - Dynamic response requirements
    • R. M. Gardner "Direct blood pressure measurement - Dynamic response requirements", Anesthesiology, Vol. 54, pp 227-236 (1981).
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 28
    • 0017669792 scopus 로고
    • Significance of intracranial hypertension in severe head injury
    • J. D. Miller et al. "Significance of intracranial hypertension in severe head injury", J. Neurosurg., Vol. 47, pp. 503-516 (1977).
    • (1977) J. Neurosurg , vol.47 , pp. 503-516
    • Miller, J.D.1
  • 29
    • 0018304477 scopus 로고
    • The outcome with aggressive treatment in severe head injuries. Part II: Acute and chronic barbiturate administration in the management of head injury
    • L. F. Marshall et al. "The outcome with aggressive treatment in severe head injuries. Part II: Acute and chronic barbiturate administration in the management of head injury", J. Neurosurg., Vol. 50, pp. 26-30 (1979).
    • (1979) J. Neurosurg , vol.50 , pp. 26-30
    • Marshall, L.F.1
  • 30
    • 78651161885 scopus 로고
    • Transmission of increased intracranial pressure: I. Within the craniospinal axis
    • T. W. Langfitt et al. "Transmission of increased intracranial pressure: I. Within the craniospinal axis", J. Neurosurg., Vol. 21, pp. 989-997 (1964).
    • (1964) J. Neurosurg , vol.21 , pp. 989-997
    • Langfitt, T.W.1
  • 31
    • 0022530227 scopus 로고
    • Inaccurate pressure readings for subarachnoid bolts
    • J. D. Miller et al. "Inaccurate pressure readings for subarachnoid bolts", Neurosurg., Vol. 19, pp. 253-255 (1986).
    • (1986) Neurosurg , vol.19 , pp. 253-255
    • Miller, J.D.1
  • 32
    • 0020702495 scopus 로고
    • A clinical comparison of subdural screw pressure measurements with ventricular pressure
    • A. D. Mendelow et al. "A clinical comparison of subdural screw pressure measurements with ventricular pressure", J. Neurosurg., Vol. 58, pp. 45-50 (1983).
    • (1983) J. Neurosurg , vol.58 , pp. 45-50
    • Mendelow, A.D.1
  • 33
    • 0022545667 scopus 로고    scopus 로고
    • B. North and P. Reilly P. Comparison among three methods of intracranial pressure recording, Neurosurg., 18, pp. 730-732 (1986).
    • B. North and P. Reilly P. "Comparison among three methods of intracranial pressure recording", Neurosurg., Vol. 18, pp. 730-732 (1986).
  • 34
    • 0026451192 scopus 로고
    • Monitoring of brain tissue pressure with a fiberoptic device
    • G. Gambardella et al. "Monitoring of brain tissue pressure with a fiberoptic device", Neurosurg., Vol. 31, pp. 918-922 (1992).
    • (1992) Neurosurg , vol.31 , pp. 918-922
    • Gambardella, G.1
  • 35
    • 1542472772 scopus 로고
    • Multicenter clinical evaluation of a new ICP device
    • Nagai H, Kamiya K. & Ishii S. Eds, Springer-Verlag, Berlin, pp
    • A. Marmarou et al. "Multicenter clinical evaluation of a new ICP device", in "Intracranial Pressure IX", (Nagai H., Kamiya K. & Ishii S. Eds.), Springer-Verlag, Berlin, pp. 18-19, (1994).
    • (1994) Intracranial Pressure IX , pp. 18-19
    • Marmarou, A.1
  • 36
    • 35648946538 scopus 로고    scopus 로고
    • M. Yoshihara et al. A fiberoptic device suitable for subdural pressure measurement, in Intracranial pressure VIII, (Avezaat C J. J., Van Eijndhoven J. H. M. & Maas A. I. R., Eds.), Springer-Verlag, Berlin, pp. 20-24 (1993).
    • M. Yoshihara et al. "A fiberoptic device suitable for subdural pressure measurement", in "Intracranial pressure VIII", (Avezaat C J. J., Van Eijndhoven J. H. M. & Maas A. I. R., Eds.), Springer-Verlag, Berlin, pp. 20-24 (1993).
  • 37
    • 35648929583 scopus 로고    scopus 로고
    • FISO Technologies Inc.: www.fiso.com, SMARTEC S.A.: www.smartec.ch or Roctest Ltd.: www.roctest.com; Those companies are all members of the Roctest Group.
    • FISO Technologies Inc.: www.fiso.com, SMARTEC S.A.: www.smartec.ch or Roctest Ltd.: www.roctest.com; Those companies are all members of the Roctest Group.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.