Miniature fiber optic pressure sensor for medical applications: An opportunity for intra-aortic balloon pumping (IABP) therapy

Author keywords

Assist device; Cardiac blood pressure; Dicrotic notch; Fabry Perot interferometer; In situ monitoring; Mechanical heart support; Micro Optical Mechanical System (MOMS); Pressure transduction; Waveform; White light interferometry

Indexed keywords

BIOMEDICAL ENGINEERING; CARDIOLOGY; FABRY-PEROT INTERFEROMETERS; MICROOPTICS; OPTICAL RESOLVING POWER; PRESSURE EFFECTS; WAVEFORM ANALYSIS;

EID: 28544437579     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.623806     Document Type: Conference Paper
Times cited : (28)

References (9)
  • 1
    • 28544449276 scopus 로고
    • "Fabry-Perot optical sensing device for measuring a physical parameter", US Patents #5,202,939 (1993) & #5,392,117
    • Belleville C. et Duplain G. "Fabry-Perot optical sensing device for measuring a physical parameter", US Patents #5,202,939 (1993) & #5,392,117 (1995)
    • (1995)
    • Belleville, C.1    Duplain, G.2
  • 2
    • 0024234445 scopus 로고
    • The intra-aortic balloon pump : A review
    • Maccioli G. A. et al. "The intra-aortic balloon pump : a review" J. Cardiothoracic Anesthesia, 2(3), 365-373 (1988)
    • (1988) J. Cardiothoracic Anesthesia , vol.2 , Issue.3 , pp. 365-373
    • Maccioli, G.A.1
  • 3
    • 0030943326 scopus 로고    scopus 로고
    • Intraaortic balloon pumping for cardiac support : Trends in practice and outcome, 1968 to 1995
    • Torchiana D. F. et al. "Intraaortic balloon pumping for cardiac support : trends in practice and outcome, 1968 to 1995" J. Thor. Cardio. Surg., 113(4), 758-769 (1997)
    • (1997) J. Thor. Cardio. Surg. , vol.113 , Issue.4 , pp. 758-769
    • Torchiana, D.F.1
  • 4
    • 0000341625 scopus 로고
    • Initial clinical experience with intraaortic baloon pumping in cardiogenic shock
    • Kantrowitz A. et al. "Initial clinical experience with intraaortic baloon pumping in cardiogenic shock" J. Am. Med. Assoc., 203(2), 135-140 (1968).
    • (1968) J. Am. Med. Assoc. , vol.203 , Issue.2 , pp. 135-140
    • Kantrowitz, A.1
  • 5
    • 0019523842 scopus 로고
    • Direct blood pressure measurement - Dynamic response requirements
    • Gardner R. M. "Direct blood pressure measurement - Dynamic response requirements" Anesthesiology, 54, 227-236 (1981)
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 6
    • 1942472497 scopus 로고    scopus 로고
    • Mechanical heart support using intraaortic balloon counterpulsation. A retrospective view and current perspectives
    • Litmathe J. et al. "Mechanical heart support using intraaortic balloon counterpulsation. A retrospective view and current perspectives" Acta Cardiol., 59(2), 159-164 (2003)
    • (2003) Acta Cardiol. , vol.59 , Issue.2 , pp. 159-164
    • Litmathe, J.1
  • 7
    • 0036768538 scopus 로고    scopus 로고
    • Reduced vascular complication after IABP insertion using smaller sized catheter and sheathless technique
    • Menon P. et al. "Reduced vascular complication after IABP insertion using smaller sized catheter and sheathless technique" Eur. J Cardio-Thoracic Surg., 22, 491-492 (2002)
    • (2002) Eur. J Cardio-thoracic Surg. , vol.22 , pp. 491-492
    • Menon, P.1
  • 9
    • 1442317139 scopus 로고    scopus 로고
    • Physiological and clinical analysis of the arterial pressure waveform in the IABP patient
    • Quaal S. J. "Physiological and clinical analysis of the arterial pressure waveform in the IABP patient" Canadian Perfusion (Intra aortic balloon pump edition), 10(2), 6-13 (2000)
    • (2000) Canadian Perfusion (Intra Aortic Balloon Pump Edition) , vol.10 , Issue.2 , pp. 6-13
    • Quaal, S.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.