-
1
-
-
2342620681
-
A new cerium (III)-selective membrane electrode based on 2-aminobenzothiazole
-
Akhond, M., Najafi, M.B., and Tashkhourian, J. 2004. A new cerium (III)-selective membrane electrode based on 2-aminobenzothiazole. Sens. Actuators B, 99: 410-415.
-
(2004)
Sens. Actuators B
, vol.99
, pp. 410-415
-
-
Akhond, M.1
Najafi, M.B.2
Tashkhourian, J.3
-
2
-
-
13844254051
-
Lanthanum-selective membrane electrode based on 2,2′-dithiodipyridine
-
Akhond, M., Najafi, M.B., and Tashkhourian, J. 2005. Lanthanum-selective membrane electrode based on 2,2′-dithiodipyridine. Anal. Chim. Acta, 531: 179-184.
-
(2005)
Anal. Chim. Acta
, vol.531
, pp. 179-184
-
-
Akhond, M.1
Najafi, M.B.2
Tashkhourian, J.3
-
3
-
-
46549096850
-
Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriers
-
Ammann, E., Pretsch, P., Simon, W., Lindner, E., Bezegh, A., and Pungor, E. 1991. Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriers. Anal. Chim. Acta, 171: 119-129.
-
(1991)
Anal. Chim. Acta
, vol.171
, pp. 119-129
-
-
Ammann, E.1
Pretsch, P.2
Simon, W.3
Lindner, E.4
Bezegh, A.5
Pungor, E.6
-
4
-
-
0030376451
-
Simultaneous spectro-fluorimetric determination of europium, dysprosium, gadolinium and terbium using chemometric methods
-
Bautista, R.D., Jiménez, A.I., Jiménez, F., and Arias, J.J. 1996. Simultaneous spectro-fluorimetric determination of europium, dysprosium, gadolinium and terbium using chemometric methods. Talanta, 43: 421-429.
-
(1996)
Talanta
, vol.43
, pp. 421-429
-
-
Bautista, R.D.1
Jiménez, A.I.2
Jiménez, F.3
Arias, J.J.4
-
5
-
-
84930167786
-
IUPAC Recommendations for nomenclature. of ion-selective electrodes
-
Buck, P. and Lindner, E. 1994. IUPAC Recommendations for nomenclature. of ion-selective electrodes. Pure & Appl. Chem., 66: 2527-2536.
-
(1994)
Pure & Appl. Chem
, vol.66
, pp. 2527-2536
-
-
Buck, P.1
Lindner, E.2
-
6
-
-
0001089945
-
Samarium(III)-selective electrode using neutral bis(thiaalkylxanthato)alkanes
-
Chowdhury, D.A., Ogata, T., Kamata, S., and Ohashi, K. 1996. Samarium(III)-selective electrode using neutral bis(thiaalkylxanthato)alkanes. Anal. Chem., 68: 366.
-
(1996)
Anal. Chem
, vol.68
, pp. 366
-
-
Chowdhury, D.A.1
Ogata, T.2
Kamata, S.3
Ohashi, K.4
-
7
-
-
0001377914
-
Selectivity-modifying influence of anionic sites in neutral-carrier-based membrane electrodes
-
Eugster, R., Gehrig, P.M., Morf, W.E., Spichiger, U.E., and Simon, W. 1991. Selectivity-modifying influence of anionic sites in neutral-carrier-based membrane electrodes. Anal. Chem., 63: 2285-2289.
-
(1991)
Anal. Chem
, vol.63
, pp. 2285-2289
-
-
Eugster, R.1
Gehrig, P.M.2
Morf, W.E.3
Spichiger, U.E.4
Simon, W.5
-
8
-
-
27844548158
-
The determination of samarium, europium, Gadolinium and dysprosium in uranium products by direct-current plasma emission-spectrometry
-
Flavelle, F. and Westland, A.D. 1986. The determination of samarium, europium, Gadolinium and dysprosium in uranium products by direct-current plasma emission-spectrometry. Talanta, 33: 445-447.
-
(1986)
Talanta
, vol.33
, pp. 445-447
-
-
Flavelle, F.1
Westland, A.D.2
-
9
-
-
33744534027
-
Therapeutic application of lanthanides
-
Fricker, S.P. 2006. Therapeutic application of lanthanides. Chem. Soc. Rev., 35: 524-533.
-
(2006)
Chem. Soc. Rev
, vol.35
, pp. 524-533
-
-
Fricker, S.P.1
-
10
-
-
0037369780
-
Gliclazide as novel carrier in construction of PVC-based La(III)-selective membrane sensor
-
Ganjali, M.R., Daftari, A., Rezapour, M., Puorsaberi, T., and Haghgoo, S. 2003. Gliclazide as novel carrier in construction of PVC-based La(III)-selective membrane sensor. Talanta, 59: 613-619.
-
(2003)
Talanta
, vol.59
, pp. 613-619
-
-
Ganjali, M.R.1
Daftari, A.2
Rezapour, M.3
Puorsaberi, T.4
Haghgoo, S.5
-
11
-
-
4544308022
-
Novel potentiometric PVC-membrane and coated graphite sensors for lanthanum(III)
-
Ganjali, M.R., Kiani-Anbouhi, R., Shamsipur, M., Poursaberi, T., Salavati-Niasari, M., Talebpour, Z., and Emami, M. 2004a. Novel potentiometric PVC-membrane and coated graphite sensors for lanthanum(III). Electroanalysis, 16: 1002-1008.
-
(2004)
Electroanalysis
, vol.16
, pp. 1002-1008
-
-
Ganjali, M.R.1
Kiani-Anbouhi, R.2
Shamsipur, M.3
Poursaberi, T.4
Salavati-Niasari, M.5
Talebpour, Z.6
Emami, M.7
-
12
-
-
1342328132
-
Novel lanthanum(III) membrane sensor based on a new N-S Schiff's base
-
Ganjali, M.R., Qomi, M., Daftari, A., Norouzi, P., Salavati-Niasari, M., and Rabbani, M. 2004b. Novel lanthanum(III) membrane sensor based on a new N-S Schiff's base. Sens. Actuators B, 98: 92-96.
-
(2004)
Sens. Actuators B
, vol.98
, pp. 92-96
-
-
Ganjali, M.R.1
Qomi, M.2
Daftari, A.3
Norouzi, P.4
Salavati-Niasari, M.5
Rabbani, M.6
-
13
-
-
3543045016
-
PPt level detection of samarium(III) with a coated graphite sensor based on an antibiotic
-
Ganjali, M.R., Rezapour, M., Pourjavid, M.R., and Haghgoo, S. 2004c. PPt level detection of samarium(III) with a coated graphite sensor based on an antibiotic. Anal. Sci., 20: 1007-1011.
-
(2004)
Anal. Sci
, vol.20
, pp. 1007-1011
-
-
Ganjali, M.R.1
Rezapour, M.2
Pourjavid, M.R.3
Haghgoo, S.4
-
14
-
-
13844272183
-
Fluoride determination in some mouth wash preparations by a novel La(III) graphite coated membrane sensor based on amitraz
-
Ganjali, M.R., Akbar, V., Ghorbani, M., Norouzi, P., and Ahmadi, A. 2005a. Fluoride determination in some mouth wash preparations by a novel La(III) graphite coated membrane sensor based on amitraz. Anal. Chim. Acta, 531: 185-191.
-
(2005)
Anal. Chim. Acta
, vol.531
, pp. 185-191
-
-
Ganjali, M.R.1
Akbar, V.2
Ghorbani, M.3
Norouzi, P.4
Ahmadi, A.5
-
15
-
-
14544275890
-
La(III) selective membrane sensor based on a new N-N Schiff's base
-
Ganjali, M.R., Matloobi, P., Ghorbani, M., Norouzi, P., and Salavati-Niasari, M. 2005b. La(III) selective membrane sensor based on a new N-N Schiff's base. Bull Korean Chem. Soc., 26: 38-42.
-
(2005)
Bull Korean Chem. Soc
, vol.26
, pp. 38-42
-
-
Ganjali, M.R.1
Matloobi, P.2
Ghorbani, M.3
Norouzi, P.4
Salavati-Niasari, M.5
-
16
-
-
28844436065
-
A new pentadentate S-N Schiff's base as a novel ionophore in construction of a novel Gd (III) membrane sensor
-
Ganjali, M.R., Rezapour, M., Norouzi, P., and Salavati-Niasari, M. 2005c. A new pentadentate S-N Schiff's base as a novel ionophore in construction of a novel Gd (III) membrane sensor. Electroanalysis, 17: 2032.
-
(2005)
Electroanalysis
, vol.17
, pp. 2032
-
-
Ganjali, M.R.1
Rezapour, M.2
Norouzi, P.3
Salavati-Niasari, M.4
-
17
-
-
33745138179
-
Construction of a highly selective and sensitive La(III) sensor based on N-(2-pyridyl)-N′-(2-methoxyphenyl)-thiourea for nano level monitoring of La(III) ions
-
Ganjali, M.R., Norouzi, P., Alizadeh, T., Tadjarodi, A., Hanifehpour, Y., and Adib, M. 2006a. Construction of a highly selective and sensitive La(III) sensor based on N-(2-pyridyl)-N′-(2-methoxyphenyl)-thiourea for nano level monitoring of La(III) ions. Electroanalysis, 18: 1091-1096.
-
(2006)
Electroanalysis
, vol.18
, pp. 1091-1096
-
-
Ganjali, M.R.1
Norouzi, P.2
Alizadeh, T.3
Tadjarodi, A.4
Hanifehpour, Y.5
Adib, M.6
-
18
-
-
33749262467
-
A novel Er(III) sensor based on a new hydrazone for themonitoring of Er(III) ions
-
Ganjali, M.R., Faridbod, F., Norouzi, P., and Adib, M. 2006b. A novel Er(III) sensor based on a new hydrazone for themonitoring of Er(III) ions. Sens. Actuators B, 120: 119-124.
-
(2006)
Sens. Actuators B
, vol.120
, pp. 119-124
-
-
Ganjali, M.R.1
Faridbod, F.2
Norouzi, P.3
Adib, M.4
-
19
-
-
33645145644
-
PPb level monitoring of lanthanum by a novel PCV-membrane sensor based on 4-methyl-2-hydrazinobenzothiazole
-
Ganjali, M.R., Norouzi, P., Shamsolahrari, L., and Ahmadi, A. 2006c. PPb level monitoring of lanthanum by a novel PCV-membrane sensor based on 4-methyl-2-hydrazinobenzothiazole. Sens. Actuators B, 114: 713-719.
-
(2006)
Sens. Actuators B
, vol.114
, pp. 713-719
-
-
Ganjali, M.R.1
Norouzi, P.2
Shamsolahrari, L.3
Ahmadi, A.4
-
20
-
-
33747096531
-
Application of 2-f[(8-amino-1-naphtyl) imino] methylg phenol as a neutral ionophore in the construction of a La(III) ion-selective sensor
-
Ganjali, M.R., Norouzi, P., Alizadeh, T., and Adib, M. 2006d. Application of 2-f[(8-amino-1-naphtyl) imino] methylg phenol as a neutral ionophore in the construction of a La(III) ion-selective sensor. Anal. Chim. Acta, 576: 275-282.
-
(2006)
Anal. Chim. Acta
, vol.576
, pp. 275-282
-
-
Ganjali, M.R.1
Norouzi, P.2
Alizadeh, T.3
Adib, M.4
-
21
-
-
33645967165
-
Novel Pr(III)-selective membrane sensor based on a new hydrazide derivative
-
Ganjali, M.R., Mirnaghi, F., Norouzi, P., and Adib, M. 2006e. Novel Pr(III)-selective membrane sensor based on a new hydrazide derivative. Sens. Actuators B, 115: 374-378.
-
(2006)
Sens. Actuators B
, vol.115
, pp. 374-378
-
-
Ganjali, M.R.1
Mirnaghi, F.2
Norouzi, P.3
Adib, M.4
-
22
-
-
33644985239
-
PPb level monitoring of Dy(III) ions by a highly sensitive and selective Dy(III) sensor based on a new asymmetrical Schiff's base
-
Ganjali, M.R., Dodangeh, M., Ghorbani, H., Norouzi, P., and Adib, M. 2006f. PPb level monitoring of Dy(III) ions by a highly sensitive and selective Dy(III) sensor based on a new asymmetrical Schiff's base. Anal. Lett., 39: 495-506.
-
(2006)
Anal. Lett
, vol.39
, pp. 495-506
-
-
Ganjali, M.R.1
Dodangeh, M.2
Ghorbani, H.3
Norouzi, P.4
Adib, M.5
-
23
-
-
33646371039
-
A novel Holmium(III) membrane sensor based on N-(1-thien-2-ylmethylene)-1, 3-benzothiazol-2-amine
-
Ganjali, M.R., Norouzi, P., Adib, M., and Ahmadalinezhad, A. 2006g. A novel Holmium(III) membrane sensor based on N-(1-thien-2-ylmethylene)-1, 3-benzothiazol-2-amine. Anal. Lett., 39: 1075-1086.
-
(2006)
Anal. Lett
, vol.39
, pp. 1075-1086
-
-
Ganjali, M.R.1
Norouzi, P.2
Adib, M.3
Ahmadalinezhad, A.4
-
24
-
-
33845640874
-
Fabrication of a highly selective Eu(III) membrane sensor based on a new S-N hexadentates schiff's base
-
Ganjali, M.R., Norouzi, P., Daftari, A., Faridbod, F., and Salavati-Niasari, M. 2007. Fabrication of a highly selective Eu(III) membrane sensor based on a new S-N hexadentates schiff's base. Sens. Actuators B, 120: 673-678.
-
(2007)
Sens. Actuators B
, vol.120
, pp. 673-678
-
-
Ganjali, M.R.1
Norouzi, P.2
Daftari, A.3
Faridbod, F.4
Salavati-Niasari, M.5
-
25
-
-
0030233333
-
Studies on tetracycline hydrochloride sorbedzirconiumtungstophosphate; La(III)-selective chelating ion exchanger
-
Gupta, A.P. and Varshney, P.K. 1996. Studies on tetracycline hydrochloride sorbedzirconiumtungstophosphate; La(III)-selective chelating ion exchanger. React. Funct.-Polym., 31: 111-116.
-
(1996)
React. Funct.-Polym
, vol.31
, pp. 111-116
-
-
Gupta, A.P.1
Varshney, P.K.2
-
26
-
-
0027312004
-
Dicarboxylate and tetracarboxylate derivatives of pyridines, bipyridines and terpyridines as liminogenic reagents for time resolved fluorometric determination of terbium and dysprosium
-
Hemmilä, I., Mukkala, V.M., Latva, M., and Kiilholma, P. 1993. Dicarboxylate and tetracarboxylate derivatives of pyridines, bipyridines and terpyridines as liminogenic reagents for time resolved fluorometric determination of terbium and dysprosium. J. Biochem. Bioph. Methods, 26: 283-290.
-
(1993)
J. Biochem. Bioph. Methods
, vol.26
, pp. 283-290
-
-
Hemmilä, I.1
Mukkala, V.M.2
Latva, M.3
Kiilholma, P.4
-
27
-
-
25044454387
-
Determination of terbium and dysprosium by atomic absorption spectrometry
-
Ishizuka, T. and Sunahara, H. 1973. Determination of terbium and dysprosium by atomic absorption spectrometry. Anal. Chim. Acta, 66: 343-349.
-
(1973)
Anal. Chim. Acta
, vol.66
, pp. 343-349
-
-
Ishizuka, T.1
Sunahara, H.2
-
28
-
-
0037880746
-
A new ionselective electrode for potentiometric determination of Ce(III)
-
Karami, H., Mousavi, M.H., Shamsipour, M., Yavari, I., and Alizadeh, A.A. 2003. A new ionselective electrode for potentiometric determination of Ce(III). Anal. Lett., 36: 1065-1078.
-
(2003)
Anal. Lett
, vol.36
, pp. 1065-1078
-
-
Karami, H.1
Mousavi, M.H.2
Shamsipour, M.3
Yavari, I.4
Alizadeh, A.A.5
-
29
-
-
0038621731
-
Ion-selective electrode for lanthanum determination in standard samples
-
Khalil, S. 2003. Ion-selective electrode for lanthanum determination in standard samples. Anal. Lett., 36: 1335.
-
(2003)
Anal. Lett
, vol.36
, pp. 1335
-
-
Khalil, S.1
-
30
-
-
0027739326
-
Determination of dysprosium in monkey serum by inductively-coupled plasma-atomic emission-spectrometry (ICP-AES) after the administration of sprodlamide injection, a new contrast-medium for magneticresonance-imaging
-
Lai, J.J. and Jamieson, G.C. 1993. Determination of dysprosium in monkey serum by inductively-coupled plasma-atomic emission-spectrometry (ICP-AES) after the administration of sprodlamide injection, a new contrast-medium for magneticresonance-imaging. J. Pharm. Biomed. Anal., 11: 1129-1134.
-
(1993)
J. Pharm. Biomed. Anal
, vol.11
, pp. 1129-1134
-
-
Lai, J.J.1
Jamieson, G.C.2
-
31
-
-
0021721652
-
Automatic spectrofluorimetric method for the determination of dysprosium as its ternary complex with EDTA and TIRON
-
Lyle, S.J. and Zatar, N.A. 1984. Automatic spectrofluorimetric method for the determination of dysprosium as its ternary complex with EDTA and TIRON. Anal. Chim. Acta, 162: 447-449.
-
(1984)
Anal. Chim. Acta
, vol.162
, pp. 447-449
-
-
Lyle, S.J.1
Zatar, N.A.2
-
32
-
-
0030985069
-
Ultra trace determination of europium in high-purity lanthanum, praseodymium, and dysprosium oxides by luminescence spectrometry
-
Mahalakshmi Sita, N., PrasadaRao, T., Iyer, C.S.P., and Damodaran, A.D. 1997. Ultra trace determination of europium in high-purity lanthanum, praseodymium, and dysprosium oxides by luminescence spectrometry. Talanta, 44: 423-426.
-
(1997)
Talanta
, vol.44
, pp. 423-426
-
-
Mahalakshmi Sita, N.1
PrasadaRao, T.2
Iyer, C.S.P.3
Damodaran, A.D.4
-
34
-
-
33947290546
-
A general purpose curve fitting program for class and research use
-
Nicely, V.A. and Dye, J.I. 1971. A general purpose curve fitting program for class and research use. J. Chem. Educ., 48: 443-448.
-
(1971)
J. Chem. Educ
, vol.48
, pp. 443-448
-
-
Nicely, V.A.1
Dye, J.I.2
-
35
-
-
0037385146
-
Solution and solid state properties of a set of procaine and procainamide derivatives
-
Olivera, M.E., Ramrez Rigo, M.V., Chattah, A.K., Levstein, P.R., Baschini, M., and Manzo, R.H. 2003. Solution and solid state properties of a set of procaine and procainamide derivatives. European J. Pharm. Sci., 18: 337-348.
-
(2003)
European J. Pharm. Sci
, vol.18
, pp. 337-348
-
-
Olivera, M.E.1
Ramrez Rigo, M.V.2
Chattah, A.K.3
Levstein, P.R.4
Baschini, M.5
Manzo, R.H.6
-
36
-
-
35648983920
-
-
Available
-
[Online]. Available: http://www.webelements.com.
-
-
-
-
37
-
-
7944235270
-
Simultaneous determination of dysprosium and iron in urine by capillary zone electrophoresis coupled to cloud point extraction
-
Ortega, C., Cerutti, S., Olsina, R.A., Martínez, L.D., and Silva, M.F. 2004. Simultaneous determination of dysprosium and iron in urine by capillary zone electrophoresis coupled to cloud point extraction. J. Pharm. Biomed. Anal., 36: 721-727.
-
(2004)
J. Pharm. Biomed. Anal
, vol.36
, pp. 721-727
-
-
Ortega, C.1
Cerutti, S.2
Olsina, R.A.3
Martínez, L.D.4
Silva, M.F.5
-
38
-
-
33646056958
-
Ion imprinted polymer based ion-selective electrode for the trace determination of dysprosium(III) ions
-
Prasad, K., Kala, R., Prasada Rao, T., and Naidu, G.R.K. 2006. Ion imprinted polymer based ion-selective electrode for the trace determination of dysprosium(III) ions. Anal. Chim. Acta, 566: 69-74.
-
(2006)
Anal. Chim. Acta
, vol.566
, pp. 69-74
-
-
Prasad, K.1
Kala, R.2
Prasada Rao, T.3
Naidu, G.R.K.4
-
39
-
-
0027325714
-
Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors
-
Rosatzin, T., Bekker, E., Suzuki, K., and Simon, W. 1993. Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors. Anal. Chim. Acta, 280: 197-208.
-
(1993)
Anal. Chim. Acta
, vol.280
, pp. 197-208
-
-
Rosatzin, T.1
Bekker, E.2
Suzuki, K.3
Simon, W.4
-
40
-
-
27644579522
-
Polymeric membrane lanthanum(III)-selective electrode based on N,N′-adipylbis(5-plenylazo salicylaldehyde hydrazone)
-
Shamsipur, M., Ershad, S., Samadi, N., Esmaeilbeig, A.R., Kia, R., and Abdolmaleki, A. 2005a. Polymeric membrane lanthanum(III)-selective electrode based on N,N′-adipylbis(5-plenylazo salicylaldehyde hydrazone). Electroanalysis, 17: 1828-1834.
-
(2005)
Electroanalysis
, vol.17
, pp. 1828-1834
-
-
Shamsipur, M.1
Ershad, S.2
Samadi, N.3
Esmaeilbeig, A.R.4
Kia, R.5
Abdolmaleki, A.6
-
41
-
-
11844263928
-
PVC membrane potentiometric sensor based on 5-pyridino-2,8-dithia[9](2,9)-1,10-phenanthroline-phane for selective determination of neodymium(III)
-
Shamsipur, M., Hosseini, M., Alizadeh, K., Mousavi, M.F., Garau, A., Lippolis, V., and Yari, A. 2005b. PVC membrane potentiometric sensor based on 5-pyridino-2,8-dithia[9](2,9)-1,10-phenanthroline-phane for selective determination of neodymium(III). Anal. Chem., 77: 276-283.
-
(2005)
Anal. Chem
, vol.77
, pp. 276-283
-
-
Shamsipur, M.1
Hosseini, M.2
Alizadeh, K.3
Mousavi, M.F.4
Garau, A.5
Lippolis, V.6
Yari, A.7
-
42
-
-
0034755412
-
PVC-based 1,3,5-trithiane coated graphite electrode for determination of cerium(III) ions
-
Shamsipur, M., Yousefi, M., Hosseini, M., and Ganjali, M.R. 2001. PVC-based 1,3,5-trithiane coated graphite electrode for determination of cerium(III) ions. Anal. Lett., 34: 2249.
-
(2001)
Anal. Lett
, vol.34
, pp. 2249
-
-
Shamsipur, M.1
Yousefi, M.2
Hosseini, M.3
Ganjali, M.R.4
-
43
-
-
35648942128
-
Cathode-ray-excited emission spectroscopy of trace rare earths: Determination of dysprosium
-
Shrader, R.E., Larach, S., and Kauffunger, R.A. 1971. Cathode-ray-excited emission spectroscopy of trace rare earths: Determination of dysprosium. Anal. Chim. Acta, 54: 162-163.
-
(1971)
Anal. Chim. Acta
, vol.54
, pp. 162-163
-
-
Shrader, R.E.1
Larach, S.2
Kauffunger, R.A.3
-
44
-
-
0344740852
-
Determination of dysprosium by resonance light scattering technique in the presence of BPMPHD
-
Sun, S., Wu, X., Yang, J., Li, L., and Wang, Y. 2004. Determination of dysprosium by resonance light scattering technique in the presence of BPMPHD. Spectrochim. Acta Part A, 60: 261-264.
-
(2004)
Spectrochim. Acta Part A
, vol.60
, pp. 261-264
-
-
Sun, S.1
Wu, X.2
Yang, J.3
Li, L.4
Wang, Y.5
-
45
-
-
25544441581
-
Rapid determination of dysprosium in rock samples by neutron activation analysis with a Ge(li) detector after chemical separation
-
Tomura, K., Onuma, H.H.N., and Hamaguchi, H. 1968. Rapid determination of dysprosium in rock samples by neutron activation analysis with a Ge(li) detector after chemical separation. Anal. Chim. Acta, 42: 389-395.
-
(1968)
Anal. Chim. Acta
, vol.42
, pp. 389-395
-
-
Tomura, K.1
Onuma, H.H.N.2
Hamaguchi, H.3
-
47
-
-
25544479518
-
Determination of europium and dysprosium in rocks by neutron-activation and high-resolution X-ray spectrometry
-
Voldet, P. and Haerdi, W. 1976. Determination of europium and dysprosium in rocks by neutron-activation and high-resolution X-ray spectrometry. Anal. Chim. Acta, 87: 227-231.
-
(1976)
Anal. Chim. Acta
, vol.87
, pp. 227-231
-
-
Voldet, P.1
Haerdi, W.2
-
48
-
-
29744435953
-
Highly selective and sensitive copper(II) membrane sensors based on 6-methyl-4-(1-phenylmethylidene) amino-3-thioxo-1,2,4-triazin-5-one as a new neutral ionophore
-
Zamani, H.A., Rajabzadeh, G., Ganjali, M.R., and Khatami, S.M. 2005. Highly selective and sensitive copper(II) membrane sensors based on 6-methyl-4-(1-phenylmethylidene) amino-3-thioxo-1,2,4-triazin-5-one as a new neutral ionophore. Electroanalysis, 17: 2260-2265.
-
(2005)
Electroanalysis
, vol.17
, pp. 2260-2265
-
-
Zamani, H.A.1
Rajabzadeh, G.2
Ganjali, M.R.3
Khatami, S.M.4
-
49
-
-
33746025642
-
Synthesis of N′-(1-pyridin-2-ylmethylene)-2-furohydrazide and its application in construction of a highly selective PVC-based membrane sensor for La(III) ions
-
Zamani, H.A., Ganjali, M.R., Norouzi, P., Adib, M., and Aceedy, M. 2006a. Synthesis of N′-(1-pyridin-2-ylmethylene)-2-furohydrazide and its application in construction of a highly selective PVC-based membrane sensor for La(III) ions. Anal. Sci., 22: 943-948.
-
(2006)
Anal. Sci
, vol.22
, pp. 943-948
-
-
Zamani, H.A.1
Ganjali, M.R.2
Norouzi, P.3
Adib, M.4
Aceedy, M.5
-
50
-
-
33845412022
-
Construction of a novel potentiometric terbium(III) membrane sensor and its application for the determination of terbium ion in binary mixture and fluoride ion in a mouth wash preparation
-
Zamani, H.A., Rajabzadeh, G., and Ganjali, M.R. 2006b. Construction of a novel potentiometric terbium(III) membrane sensor and its application for the determination of terbium ion in binary mixture and fluoride ion in a mouth wash preparation. J. Brazilian Chem. Soc., 17: 1297.
-
(2006)
J. Brazilian Chem. Soc
, vol.17
, pp. 1297
-
-
Zamani, H.A.1
Rajabzadeh, G.2
Ganjali, M.R.3
-
51
-
-
33646499451
-
A highly selective and sensitive barium(II)-selective PVC membrane based on dimethyl 1-acetyl-8-oxo-2,8-dihydro-1hpyra-zolo[5,1-a]isoindole-2,3-dicarboxylate
-
Zamani, H.A., Abedini-Torghabeh, J., and Ganjali, M.R. 2006c. A highly selective and sensitive barium(II)-selective PVC membrane based on dimethyl 1-acetyl-8-oxo-2,8-dihydro-1hpyra-zolo[5,1-a]isoindole-2,3-dicarboxylate. Electroanalysis, 18: 888-893.
-
(2006)
Electroanalysis
, vol.18
, pp. 888-893
-
-
Zamani, H.A.1
Abedini-Torghabeh, J.2
Ganjali, M.R.3
-
52
-
-
33845682865
-
Construction of a highly selective PVC-based membrane sensor for Ce(III) ions
-
Zamani, H.A., Ganjali, M.R., and Adib, M. 2007a. Construction of a highly selective PVC-based membrane sensor for Ce(III) ions. Sens. Actuator B, 120: 545-550.
-
(2007)
Sens. Actuator B
, vol.120
, pp. 545-550
-
-
Zamani, H.A.1
Ganjali, M.R.2
Adib, M.3
-
53
-
-
33846396301
-
A New Europium(III) PVC Membrane Potentiometric Sensor Based on 4-(2- hydroxybenzylideneamino)-6-methyl-3-thioxo-3,4- dihydro-1,2,4-triazin-5(2 H)-one
-
Zamani, H.A., Rajabzadeh, G., and Ganjali, M.R. 2007b. A New Europium(III) PVC Membrane Potentiometric Sensor Based on 4-(2- hydroxybenzylideneamino)-6-methyl-3-thioxo-3,4- dihydro-1,2,4-triazin-5(2 H)-one. Bull. Chem. Soc. Japan, 80: 172-177.
-
(2007)
Bull. Chem. Soc. Japan
, vol.80
, pp. 172-177
-
-
Zamani, H.A.1
Rajabzadeh, G.2
Ganjali, M.R.3
|