메뉴 건너뛰기




Volumn 120, Issue 2, 2007, Pages 673-678

Fabrication of a highly selective Eu(III) membrane sensor based on a new S-N hexadentates Schiff's base

Author keywords

Eu(III); Ion selective electrode; S N hexadentates Schiff's base

Indexed keywords

BINARY MIXTURES; COMPOSITION; CONCENTRATION (PROCESS); ION SELECTIVE ELECTRODES; PH EFFECTS; SYNTHESIS (CHEMICAL);

EID: 33845640874     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2006.03.028     Document Type: Article
Times cited : (107)

References (29)
  • 2
    • 25444448500 scopus 로고    scopus 로고
    • Synthesis of thiophene-2-carbaldehyde-(7-methyl-1,3-benzothiazol-2-yl)hydrazone and its application as an ionophore in the construction of a novel thulium (III) selective membrane sensor
    • Ganjali M.R., Rasoolipour S., Rezapour M., Norouzi P., and Adib M. Synthesis of thiophene-2-carbaldehyde-(7-methyl-1,3-benzothiazol-2-yl)hydrazone and its application as an ionophore in the construction of a novel thulium (III) selective membrane sensor. Electrochem. Commun. 7 (2005) 989-994
    • (2005) Electrochem. Commun. , vol.7 , pp. 989-994
    • Ganjali, M.R.1    Rasoolipour, S.2    Rezapour, M.3    Norouzi, P.4    Adib, M.5
  • 3
    • 0001089945 scopus 로고    scopus 로고
    • Samarium(III)-selective electrode using neutral bis(thiaalkylxanthato)alkanes
    • Chowdhury D.A., Ogata T., Kamata S., and Ohashi K. Samarium(III)-selective electrode using neutral bis(thiaalkylxanthato)alkanes. Anal. Chem. 68 (1996) 366-370
    • (1996) Anal. Chem. , vol.68 , pp. 366-370
    • Chowdhury, D.A.1    Ogata, T.2    Kamata, S.3    Ohashi, K.4
  • 4
    • 24944591099 scopus 로고    scopus 로고
    • Novel ytterbium(III) selective membrane sensor based on N-(2-pyridyl)-N′-(2-methoxyphenyl)-thiourea as an excellent carrier and its application to determination of fluoride in mouth wash preparation samples
    • Ganjali M.R., Rasoolipour S., Rezapour M., Norouzi P., Tajarodi A., and Hanifehpour Y. Novel ytterbium(III) selective membrane sensor based on N-(2-pyridyl)-N′-(2-methoxyphenyl)-thiourea as an excellent carrier and its application to determination of fluoride in mouth wash preparation samples. Electroanalysis 17 (2005) 1534-1539
    • (2005) Electroanalysis , vol.17 , pp. 1534-1539
    • Ganjali, M.R.1    Rasoolipour, S.2    Rezapour, M.3    Norouzi, P.4    Tajarodi, A.5    Hanifehpour, Y.6
  • 6
    • 31244434262 scopus 로고    scopus 로고
    • Ion-selective solvent polymeric membrane electrodes based on 1-phenyl-3-methyl-4-acyl-5-pyrazolones for trivalent lanthanoid ions
    • Ito T., and Coto C. Ion-selective solvent polymeric membrane electrodes based on 1-phenyl-3-methyl-4-acyl-5-pyrazolones for trivalent lanthanoid ions. J. Trace Microprobe Tech. 19 (2001) 601-613
    • (2001) J. Trace Microprobe Tech. , vol.19 , pp. 601-613
    • Ito, T.1    Coto, C.2
  • 7
    • 7944220832 scopus 로고    scopus 로고
    • An Eu(III) sensor based on N,N-diethyl-N-(4-hydroxy-6-methylpyridin-2-yl)guanidine
    • Ganjali M.R., Rahimi M., Maddah B., Moghimi A., and Borhany S. An Eu(III) sensor based on N,N-diethyl-N-(4-hydroxy-6-methylpyridin-2-yl)guanidine. Anal. Sci. 20 (2004) 1427-1431
    • (2004) Anal. Sci. , vol.20 , pp. 1427-1431
    • Ganjali, M.R.1    Rahimi, M.2    Maddah, B.3    Moghimi, A.4    Borhany, S.5
  • 8
    • 3543045016 scopus 로고    scopus 로고
    • ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic
    • Ganjali M.R., Rezapour M., Pourjavid M.R., and Haghgoo S. ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic. Anal. Sci. 20 (2004) 1007-1011
    • (2004) Anal. Sci. , vol.20 , pp. 1007-1011
    • Ganjali, M.R.1    Rezapour, M.2    Pourjavid, M.R.3    Haghgoo, S.4
  • 9
    • 0035850587 scopus 로고    scopus 로고
    • Lanthanoid ion-selective solvent polymeric membrane electrode based on 1-phenyl-3-methyl-4-octadecanoyl-5-pyrazolone
    • Ito T., Goto C., and Noguchi K. Lanthanoid ion-selective solvent polymeric membrane electrode based on 1-phenyl-3-methyl-4-octadecanoyl-5-pyrazolone. Anal. Chim. Acta 443 (2001) 41-51
    • (2001) Anal. Chim. Acta , vol.443 , pp. 41-51
    • Ito, T.1    Goto, C.2    Noguchi, K.3
  • 12
    • 0038391445 scopus 로고    scopus 로고
    • Novel Y(III) PVC-based membrane microelectrode based on a new S-N Schiff's base
    • Ganjali M.R., Daftari A., Norouzi P., and Salavati-Niasari M. Novel Y(III) PVC-based membrane microelectrode based on a new S-N Schiff's base. Anal. Lett. 36 (2003) 1511-1522
    • (2003) Anal. Lett. , vol.36 , pp. 1511-1522
    • Ganjali, M.R.1    Daftari, A.2    Norouzi, P.3    Salavati-Niasari, M.4
  • 13
    • 0141679405 scopus 로고    scopus 로고
    • A novel PVC membrane sensor for selective determination of cerium(III) ions
    • Gaber A.A.A. A novel PVC membrane sensor for selective determination of cerium(III) ions. Anal. Lett. 36 (2003) 2585-2596
    • (2003) Anal. Lett. , vol.36 , pp. 2585-2596
    • Gaber, A.A.A.1
  • 14
    • 3543045016 scopus 로고    scopus 로고
    • ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic
    • Ganjali M.R., Rezapour M., Pourjavid M.R., and Haghgoo S. ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic. Anal. Sci. 20 (2004) 1007-1011
    • (2004) Anal. Sci. , vol.20 , pp. 1007-1011
    • Ganjali, M.R.1    Rezapour, M.2    Pourjavid, M.R.3    Haghgoo, S.4
  • 15
    • 0037327707 scopus 로고    scopus 로고
    • Novel potentiometric membrane sensor for the determination of trace amounts of chromium(III) ions
    • Ganjali M.R., Mizani F., Salavati-Niasari M., and Javanbakht M. Novel potentiometric membrane sensor for the determination of trace amounts of chromium(III) ions. Anal. Sci. 19 (2003) 235-238
    • (2003) Anal. Sci. , vol.19 , pp. 235-238
    • Ganjali, M.R.1    Mizani, F.2    Salavati-Niasari, M.3    Javanbakht, M.4
  • 16
    • 0038621731 scopus 로고    scopus 로고
    • Ion-selective electrode for lanthanum determination in standard samples
    • Khalil S. Ion-selective electrode for lanthanum determination in standard samples. Anal. Lett. 36 (2003) 1335-1349
    • (2003) Anal. Lett. , vol.36 , pp. 1335-1349
    • Khalil, S.1
  • 17
    • 33645967165 scopus 로고    scopus 로고
    • Novel Pr(III) selective membrane sensor based on a new hydrazide derivative
    • Ganjali M.R., Mirnaghi F.S., Norouzi P., and Adib M. Novel Pr(III) selective membrane sensor based on a new hydrazide derivative. Sens. Actuators B 115 (2006) 374
    • (2006) Sens. Actuators B , vol.115 , pp. 374
    • Ganjali, M.R.1    Mirnaghi, F.S.2    Norouzi, P.3    Adib, M.4
  • 18
    • 33645153149 scopus 로고    scopus 로고
    • Nano-level monitoring of ytterbium (III) by a novel ytterbium (III) membrane sensor based on 3-hydroxy-N′-[(2-hydroxyphenyl)methylene]-2-naphthohydrazide
    • Ganjali M.R., Norouzi P., Tamaddon A., and Adib M. Nano-level monitoring of ytterbium (III) by a novel ytterbium (III) membrane sensor based on 3-hydroxy-N′-[(2-hydroxyphenyl)methylene]-2-naphthohydrazide. Sens. Actuators B 114 (2006) 855
    • (2006) Sens. Actuators B , vol.114 , pp. 855
    • Ganjali, M.R.1    Norouzi, P.2    Tamaddon, A.3    Adib, M.4
  • 20
    • 0035649029 scopus 로고    scopus 로고
    • Thermodynamic study of the interaction between some recently synthesized benzo-substituted macrocyclic diamides with some pyridinium ion derivatives in acetonitrile solution
    • Ganjali M.R., Zargazi M.H., and Mohajeri A. Thermodynamic study of the interaction between some recently synthesized benzo-substituted macrocyclic diamides with some pyridinium ion derivatives in acetonitrile solution. Pol. J. Chem. 75 (2001) 743-749
    • (2001) Pol. J. Chem. , vol.75 , pp. 743-749
    • Ganjali, M.R.1    Zargazi, M.H.2    Mohajeri, A.3
  • 22
    • 0037369780 scopus 로고    scopus 로고
    • Gliclazide as novel carrier in construction of PVC-based La (III)-selective membrane sensor
    • Ganjali M.R., Daftari A., and Rezapour M. Gliclazide as novel carrier in construction of PVC-based La (III)-selective membrane sensor. Talanta 59 (2003) 613-619
    • (2003) Talanta , vol.59 , pp. 613-619
    • Ganjali, M.R.1    Daftari, A.2    Rezapour, M.3
  • 23
    • 0842330863 scopus 로고    scopus 로고
    • PVC-based dicyclohexano-18-crown-6 sensor for La(III) ions
    • Mittal S.K., Kumar A., and Sharma H.K. PVC-based dicyclohexano-18-crown-6 sensor for La(III) ions. Talanta 62 (2004) 801-805
    • (2004) Talanta , vol.62 , pp. 801-805
    • Mittal, S.K.1    Kumar, A.2    Sharma, H.K.3
  • 24
    • 0030233333 scopus 로고    scopus 로고
    • Studies on tetracycline hydrochloride sorbedzirconium tungstophosphate; La (III)-selective chelating ion exchanger
    • Gupta A.P., and Varshney P.K. Studies on tetracycline hydrochloride sorbedzirconium tungstophosphate; La (III)-selective chelating ion exchanger. React. Funct. Polym. 31 (1996) 111-116
    • (1996) React. Funct. Polym. , vol.31 , pp. 111-116
    • Gupta, A.P.1    Varshney, P.K.2
  • 26
    • 0001377914 scopus 로고
    • Selectivity-modifieng influence of anionic sites in neutral-carrier-based membrane electrodes
    • Eugster R., Gehring P.M., Morf W.E., Spichiger U., and Simon W. Selectivity-modifieng influence of anionic sites in neutral-carrier-based membrane electrodes. Anal. Chem. 63 (1990) 2285-2289
    • (1990) Anal. Chem. , vol.63 , pp. 2285-2289
    • Eugster, R.1    Gehring, P.M.2    Morf, W.E.3    Spichiger, U.4    Simon, W.5
  • 27
    • 0027325714 scopus 로고
    • Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors
    • Rosatzin T., Bakker E., Suzuki K., and Simon W. Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors. Anal. Chim. Acta. 280 (1993) 197-208
    • (1993) Anal. Chim. Acta. , vol.280 , pp. 197-208
    • Rosatzin, T.1    Bakker, E.2    Suzuki, K.3    Simon, W.4
  • 28
    • 84956088296 scopus 로고    scopus 로고
    • IUPAC Analytical Chemistry Division, Commission on Analytical Nomenclature. Recommendations for Nomenclature for Ion Selective Electrodes, Pure Appl. Chem. 48 (1976) 127-135.
  • 29
    • 84876596105 scopus 로고
    • Selectivity coefficient for ion selective electrodes recommended methods for reporting K-A,B(POT) values
    • Umezawa Y., Umezawa K., and Sato H. Selectivity coefficient for ion selective electrodes recommended methods for reporting K-A,B(POT) values. Pure Appl. Chem. 67 (1995) 507-518
    • (1995) Pure Appl. Chem. , vol.67 , pp. 507-518
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.