Volumn 43, Issue 3, 2004, Pages 307-314

Improved energy efficiency for CFC domestic refrigerators retrofitted with ozone-friendly HFC134a/HC refrigerant mixture

Author keywords

CFC phase out; COP improvement; HFC134a HC mixtures; Household refrigerator; POE oil problems; Retrofitting; Zeotrope

Indexed keywords

CHLOROFLUOROCARBONS; DOMESTIC APPLIANCES; ENERGY EFFICIENCY; MIXTURES; RETROFITTING;

EID: 33344467309     PISSN: 12900729     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijthermalsci.2003.08.002     Document Type: Article
Times cited : (63)

References (23)
  • 2
    • 38249020691 scopus 로고
    • Commercial refrigeration and CFCs
    • E.B. Muir Commercial refrigeration and CFCs Internat. J. Refrigeration 13 1995 106 112
    • (1995) Internat. J. Refrigeration , vol.13 , pp. 106-112
    • Muir, E.B.1
  • 4
    • 0026191095 scopus 로고
    • Performance simulation of single-evaporator domestic refrigeration charged with pure and mixed refrigerants
    • D.S. Jung, and R. Radermacher Performance simulation of single-evaporator domestic refrigeration charged with pure and mixed refrigerants Internat. J. Refrigeration 14 1991 223 232
    • (1991) Internat. J. Refrigeration , vol.14 , pp. 223-232
    • Jung, D.S.1    Radermacher, R.2
  • 5
    • 0001164452 scopus 로고
    • Retrofitting HFC134a into existing CFC12 systems
    • N.E. Carpenter Retrofitting HFC134a into existing CFC12 systems Internat. J. Refrigeration 15 1992 332 339
    • (1992) Internat. J. Refrigeration , vol.15 , pp. 332-339
    • Carpenter, N.E.1
  • 6
    • 0030704496 scopus 로고    scopus 로고
    • Experimental evaluation of refrigerant mixtures as substitutes for CFC12 and R502
    • R. Camporese, G. Bigolaro, and S. Bobbo Experimental evaluation of refrigerant mixtures as substitutes for CFC12 and R502 Internat. J. Refrigeration 20 1997 22 31
    • (1997) Internat. J. Refrigeration , vol.20 , pp. 22-31
    • Camporese, R.1    Bigolaro, G.2    Bobbo, S.3
  • 7
    • 0028446822 scopus 로고
    • Performance evaluation of two azeotropic refrigerant mixtures of HFC134a with HC290 and HC600a
    • M.S. Kim, W.J. Mulroy, and D.A. Didion Performance evaluation of two azeotropic refrigerant mixtures of HFC134a with HC290 and HC600a Trans. ASME 116 1994 148 154
    • (1994) Trans. ASME , vol.116 , pp. 148-154
    • Kim, M.S.1    Mulroy, W.J.2    Didion, D.A.3
  • 9
    • 0032315269 scopus 로고    scopus 로고
    • Synopsis of residential refrigerator/freezer alternative refrigerants evaluation
    • E. Baskin Synopsis of residential refrigerator/freezer alternative refrigerants evaluation ASHRAE Trans. 1998 266 273
    • (1998) ASHRAE Trans. , pp. 266-273
    • Baskin, E.1
  • 10
    • 0345425352 scopus 로고    scopus 로고
    • Thermodynamic performance of nonazeotropic HFC134a/HFC143a refrigerant mixtures
    • N. Kamal, R.J. Bandorawalla, M.S. High, and K.A.M. Gasem Thermodynamic performance of nonazeotropic HFC134a/HFC143a refrigerant mixtures Heat Transfer Eng. 21 2000 46 54
    • (2000) Heat Transfer Eng. , vol.21 , pp. 46-54
    • Kamal, N.1    Bandorawalla, R.J.2    High, M.S.3    Gasem, K.A.M.4
  • 11
    • 0033319375 scopus 로고    scopus 로고
    • Physical and chemical properties of refrigeration lubricants
    • S. Motoshi Physical and chemical properties of refrigeration lubricants ASHRAE Trans. 1999 983 993
    • (1999) ASHRAE Trans. , pp. 983-993
    • Motoshi, S.1
  • 12
    • 0038048052 scopus 로고
    • Two-phase heat exchange for new refrigerants and their mixtures
    • K. Stephan Two-phase heat exchange for new refrigerants and their mixtures Internat. J. Refrigeration 18 1995 198 209
    • (1995) Internat. J. Refrigeration , vol.18 , pp. 198-209
    • Stephan, K.1
  • 14
    • 0030719048 scopus 로고    scopus 로고
    • Concentration shift when using refrigerant mixtures
    • H. Kruse, and F. Wieschollek Concentration shift when using refrigerant mixtures ASHRAE Trans. 1997 747 755
    • (1997) ASHRAE Trans. , pp. 747-755
    • Kruse, H.1    Wieschollek, F.2
  • 20
    • 0348026719 scopus 로고
    • Performance and safety of LPG refrigerants
    • Proceedings of the Fuel for Change Conference
    • I.L. Maclaine-cross, and E. Leonardi Performance and safety of LPG refrigerants Paradise Queensland, Australia Proceedings of the Fuel for Change Conference 1995 149 168
    • (1995) Paradise Queensland, Australia , pp. 149-168
    • MacLaine-Cross, I.L.1    Leonardi, E.2
  • 22
    • 0028500616 scopus 로고
    • Evaluation of suction-line/liquid-line heat exchange in the refrigeration cycle
    • P.A. Domanski, and D.A. Didion Evaluation of suction-line/liquid-line heat exchange in the refrigeration cycle Internat. J. Refrigeration 17 1994 487 493
    • (1994) Internat. J. Refrigeration , vol.17 , pp. 487-493
    • Domanski, P.A.1    Didion, D.A.2
  • 23
    • 0030707214 scopus 로고    scopus 로고
    • Modelling and testing of fractionation effects with refrigerant blends in an actual residential heat pump system
    • R.B. Frank, and R.P. Dennis Modelling and testing of fractionation effects with refrigerant blends in an actual residential heat pump system ASHRAE Trans. 1997 781 794
    • (1997) ASHRAE Trans. , pp. 781-794
    • Frank, R.B.1    Dennis, R.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.