메뉴 건너뛰기




Volumn 18, Issue 11, 2007, Pages 1909-1913

Probing the Mechanisms of an Air Amplifier Using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROSPRAY IONIZATION; FLUORESCENCE SPECTROSCOPY; FLUORESCENT SCREENS; MASS SPECTROMETERS; STAINLESS STEEL;

EID: 35449005617     PISSN: 10440305     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jasms.2007.08.006     Document Type: Article
Times cited : (16)

References (26)
  • 1
    • 0024438708 scopus 로고
    • Electrospray Ionization for Mass-Spectrometry of Large Biomolecules
    • Fenn J.B., Mann M., Meng C.K., Wong S.F., and Whitehouse C.M. Electrospray Ionization for Mass-Spectrometry of Large Biomolecules. Science 246 4926 (1989) 64-71
    • (1989) Science , vol.246 , Issue.4926 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Meng, C.K.3    Wong, S.F.4    Whitehouse, C.M.5
  • 2
    • 0025424768 scopus 로고
    • New Developments in Biochemical Mass-Spectrometry-Electrospray Ionization
    • Smith R.D., Loo J.A., Edmonds C.G., Barinaga C.J., and Udseth H.R. New Developments in Biochemical Mass-Spectrometry-Electrospray Ionization. Anal. Chem. 62 9 (1990) 882-899
    • (1990) Anal. Chem. , vol.62 , Issue.9 , pp. 882-899
    • Smith, R.D.1    Loo, J.A.2    Edmonds, C.G.3    Barinaga, C.J.4    Udseth, H.R.5
  • 3
    • 12044253267 scopus 로고
    • From Ions in Solution to Ions in the Gas-Phase-the Mechanism of Electrospray Mass-Spectrometry
    • Kebarle P., and Tang L. From Ions in Solution to Ions in the Gas-Phase-the Mechanism of Electrospray Mass-Spectrometry. Anal. Chem. 65 22 (1993) A972-A986
    • (1993) Anal. Chem. , vol.65 , Issue.22
    • Kebarle, P.1    Tang, L.2
  • 4
    • 0000906935 scopus 로고
    • Dependence of Ion Intensity in Electrospray Mass-Spectrometry on the Concentration of the Analytes in the Electrosprayed Solution
    • Tang L., and Kebarle P. Dependence of Ion Intensity in Electrospray Mass-Spectrometry on the Concentration of the Analytes in the Electrosprayed Solution. Anal. Chem. 65 24 (1993) 3654-3668
    • (1993) Anal. Chem. , vol.65 , Issue.24 , pp. 3654-3668
    • Tang, L.1    Kebarle, P.2
  • 5
    • 0000028373 scopus 로고    scopus 로고
    • On Cluster Ions, Ion Transmission, and Linear Dynamic Range Limitations in Electrospray (Ionspray) Mass Spectrometry
    • Zook D.R., and Bruins A.P. On Cluster Ions, Ion Transmission, and Linear Dynamic Range Limitations in Electrospray (Ionspray) Mass Spectrometry. Int. J. Mass Spectrom. Ion Phys. 162 1/3 (1997) 129-147
    • (1997) Int. J. Mass Spectrom. Ion Phys. , vol.162 , Issue.1-3 , pp. 129-147
    • Zook, D.R.1    Bruins, A.P.2
  • 6
    • 0035497781 scopus 로고    scopus 로고
    • Practical Implications of Some Recent Studies in Electrospray Ionization Fundamentals
    • Cech N.B., and Enke C.G. Practical Implications of Some Recent Studies in Electrospray Ionization Fundamentals. Mass Spectrom. Rev. 20 6 (2001) 362-387
    • (2001) Mass Spectrom. Rev. , vol.20 , Issue.6 , pp. 362-387
    • Cech, N.B.1    Enke, C.G.2
  • 7
    • 34548127562 scopus 로고    scopus 로고
    • Ionization and Transmission Efficiency in an Electrospray Ionization-Mass Spectrometry Interface
    • in press
    • Page J.S., Kelly R.T., Tang K., and Smith R.D. Ionization and Transmission Efficiency in an Electrospray Ionization-Mass Spectrometry Interface. J. Am. Soc. Mass Spectrom. (2007) in press
    • (2007) J. Am. Soc. Mass Spectrom.
    • Page, J.S.1    Kelly, R.T.2    Tang, K.3    Smith, R.D.4
  • 8
    • 0030670216 scopus 로고    scopus 로고
    • A Novel Ion Funnel for Focusing Ions at Elevated Pressure Using Electrospray Ionization Mass Spectrometry
    • Shaffer S.A., Tang K.Q., Anderson G.A., Prior D.C., Udseth H.R., and Smith R.D. A Novel Ion Funnel for Focusing Ions at Elevated Pressure Using Electrospray Ionization Mass Spectrometry. Rapid Commun. Mass Spectrom. 11 16 (1997) 1813-1817
    • (1997) Rapid Commun. Mass Spectrom. , vol.11 , Issue.16 , pp. 1813-1817
    • Shaffer, S.A.1    Tang, K.Q.2    Anderson, G.A.3    Prior, D.C.4    Udseth, H.R.5    Smith, R.D.6
  • 10
    • 0034668016 scopus 로고    scopus 로고
    • Improved Ion Transmission from Atmospheric Pressure to High Vacuum Using a Multicapillary Inlet and Electrodynamic Ion Funnel Interface
    • Kim T., Udseth H.R., and Smith R.D. Improved Ion Transmission from Atmospheric Pressure to High Vacuum Using a Multicapillary Inlet and Electrodynamic Ion Funnel Interface. Anal. Chem. 72 20 (2000) 5014-5019
    • (2000) Anal. Chem. , vol.72 , Issue.20 , pp. 5014-5019
    • Kim, T.1    Udseth, H.R.2    Smith, R.D.3
  • 11
    • 0000741268 scopus 로고
    • A New Method of Separation of Multi-Atomic Ions by Mobility at Atmospheric-Pressure Using a High-Frequency Amplitude-Asymmetric Strong Electric-Field
    • Buryakov I.A., Krylov E.V., Nazarov E.G., and Rasulev U.K. A New Method of Separation of Multi-Atomic Ions by Mobility at Atmospheric-Pressure Using a High-Frequency Amplitude-Asymmetric Strong Electric-Field. Int. J. Mass Spectrom. Ion Phys. 128 3 (1993) 143-148
    • (1993) Int. J. Mass Spectrom. Ion Phys. , vol.128 , Issue.3 , pp. 143-148
    • Buryakov, I.A.1    Krylov, E.V.2    Nazarov, E.G.3    Rasulev, U.K.4
  • 12
    • 0033168983 scopus 로고    scopus 로고
    • Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometry
    • Purves R.W., and Guevremont R. Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometry. Anal. Chem. 71 13 (1999) 2346-2357
    • (1999) Anal. Chem. , vol.71 , Issue.13 , pp. 2346-2357
    • Purves, R.W.1    Guevremont, R.2
  • 15
    • 3242713097 scopus 로고    scopus 로고
    • Analytical Performance of a Venturi Device Integrated into an Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometer for Analysis of Nucleic Acids
    • Hawkridge A.M., Zhou L., Lee M.L., and Muddiman D.C. Analytical Performance of a Venturi Device Integrated into an Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometer for Analysis of Nucleic Acids. Anal. Chem. 76 14 (2004) 4118-4122
    • (2004) Anal. Chem. , vol.76 , Issue.14 , pp. 4118-4122
    • Hawkridge, A.M.1    Zhou, L.2    Lee, M.L.3    Muddiman, D.C.4
  • 16
    • 26644459976 scopus 로고    scopus 로고
    • Gentle Protein Ionization Assisted by High-Velocity Gas Flow
    • Yang P.X., Cooks R.G., Ouyang Z., Hawkridge A.M., and Muddiman D.C. Gentle Protein Ionization Assisted by High-Velocity Gas Flow. Anal. Chem. 77 19 (2005) 6174-6183
    • (2005) Anal. Chem. , vol.77 , Issue.19 , pp. 6174-6183
    • Yang, P.X.1    Cooks, R.G.2    Ouyang, Z.3    Hawkridge, A.M.4    Muddiman, D.C.5
  • 17
    • 33745601934 scopus 로고    scopus 로고
    • New Interface Plate for Microspray Ionization Mass Spectrometry
    • Zhou L., Zhai L.L., Yue B.F., Lee E.D., and Lee M.L. New Interface Plate for Microspray Ionization Mass Spectrometry. Anal. Bioanal. Chem. 385 6 (2006) 1087-1091
    • (2006) Anal. Bioanal. Chem. , vol.385 , Issue.6 , pp. 1087-1091
    • Zhou, L.1    Zhai, L.L.2    Yue, B.F.3    Lee, E.D.4    Lee, M.L.5
  • 18
    • 0001510590 scopus 로고
    • Ion Formation from Charged Droplets-Roles of Geometry, Energy, and Time
    • Fenn J.B. Ion Formation from Charged Droplets-Roles of Geometry, Energy, and Time. J. Am. Soc. Mass Spectrom. 4 7 (1993) 524-535
    • (1993) J. Am. Soc. Mass Spectrom. , vol.4 , Issue.7 , pp. 524-535
    • Fenn, J.B.1
  • 19
    • 0035122575 scopus 로고    scopus 로고
    • Charge Reduction Lowers Mass Resolving Power for Isotopically Resolved Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectra
    • Marshall A.G., and Hendrickson C.L. Charge Reduction Lowers Mass Resolving Power for Isotopically Resolved Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectra. Rapid Commun. Mass Spectrom. 15 3 (2001) 232-235
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , Issue.3 , pp. 232-235
    • Marshall, A.G.1    Hendrickson, C.L.2
  • 20
    • 18044376202 scopus 로고    scopus 로고
    • Leveling Response Factors in the Electrospray Ionization Process Using a Heated Capillary Interface
    • Frahm J.L., and Muddiman D.C. Leveling Response Factors in the Electrospray Ionization Process Using a Heated Capillary Interface. J. Am. Soc. Mass Spectrom. 16 5 (2005) 772-778
    • (2005) J. Am. Soc. Mass Spectrom. , vol.16 , Issue.5 , pp. 772-778
    • Frahm, J.L.1    Muddiman, D.C.2
  • 21
    • 5644249240 scopus 로고    scopus 로고
    • Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
    • Takats Z., Wiseman J.M., Gologan B., and Cooks R.G. Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization. Science 306 5695 (2004) 471-473
    • (2004) Science , vol.306 , Issue.5695 , pp. 471-473
    • Takats, Z.1    Wiseman, J.M.2    Gologan, B.3    Cooks, R.G.4
  • 22
    • 33751094563 scopus 로고    scopus 로고
    • Direct High-Resolution Peptide and Protein Analysis by Desorption Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Bereman M.S., Nyadong L., Fernandez F.M., and Muddiman D.C. Direct High-Resolution Peptide and Protein Analysis by Desorption Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Rapid Commun. Mass Spectrom. 20 22 (2006) 3409-3411
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , Issue.22 , pp. 3409-3411
    • Bereman, M.S.1    Nyadong, L.2    Fernandez, F.M.3    Muddiman, D.C.4
  • 23
    • 33751334373 scopus 로고    scopus 로고
    • Generation and Detection of Multiply-Charged Peptides and Proteins by Matrix-Assisted Laser Desorption Electrospray Ionization (MALDESI) Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Sampson J.S., Hawkridge A.M., and Muddiman D.C. Generation and Detection of Multiply-Charged Peptides and Proteins by Matrix-Assisted Laser Desorption Electrospray Ionization (MALDESI) Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Am. Soc. Mass Spectrom. 17 12 (2006) 1712-1716
    • (2006) J. Am. Soc. Mass Spectrom. , vol.17 , Issue.12 , pp. 1712-1716
    • Sampson, J.S.1    Hawkridge, A.M.2    Muddiman, D.C.3
  • 24
    • 33947725497 scopus 로고    scopus 로고
    • Direct Characterization of Intact Polypeptides by Matrix-Assisted Laser Desorption Electrospray Ionization Quadrupole Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Sampson J.S., Hawkridge A.M., and Muddiman D.C. Direct Characterization of Intact Polypeptides by Matrix-Assisted Laser Desorption Electrospray Ionization Quadrupole Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Rapid Commun. Mass Spectrom. 21 7 (2007) 1150-1154
    • (2007) Rapid Commun. Mass Spectrom. , vol.21 , Issue.7 , pp. 1150-1154
    • Sampson, J.S.1    Hawkridge, A.M.2    Muddiman, D.C.3
  • 26
    • 20844459137 scopus 로고    scopus 로고
    • Nanoelectrospray Ion Generation for High-Throughput Mass Spectrometry Using a Micromachined Ultrasonic Ejector Array
    • Aderogba S., Meacham J.M., Degertekin F.L., Fedorov A.G., and Fernandez F.M. Nanoelectrospray Ion Generation for High-Throughput Mass Spectrometry Using a Micromachined Ultrasonic Ejector Array. Applied Phys. Lett. 86 20 (2005) 203110-203113
    • (2005) Applied Phys. Lett. , vol.86 , Issue.20 , pp. 203110-203113
    • Aderogba, S.1    Meacham, J.M.2    Degertekin, F.L.3    Fedorov, A.G.4    Fernandez, F.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.