메뉴 건너뛰기




Volumn 29, Issue 2, 2008, Pages 558-561

Towards an improved development process for new hip prostheses

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; BIOMEDICAL ENGINEERING; FATIGUE OF MATERIALS; GEOMETRY; STIFFNESS; STRENGTH OF MATERIALS; STRESS ANALYSIS; WEAR OF MATERIALS;

EID: 35348975978     PISSN: 02613069     EISSN: 18734197     Source Type: Journal    
DOI: 10.1016/j.matdes.2007.01.001     Document Type: Article
Times cited : (14)

References (16)
  • 1
    • 0029873166 scopus 로고    scopus 로고
    • Stanmore compared to Charnley total hip replacement: a prospective study of 413 arthroplasties
    • Marston R.A., Cobb A.G., and Bentley G. Stanmore compared to Charnley total hip replacement: a prospective study of 413 arthroplasties. J Bone Jt Surg 78B (1996) 178-184
    • (1996) J Bone Jt Surg , vol.78 B , pp. 178-184
    • Marston, R.A.1    Cobb, A.G.2    Bentley, G.3
  • 2
    • 18144366615 scopus 로고    scopus 로고
    • Oxidised zirconium: a potentially longer lasting hip implant
    • Good V., Widding K., Hunter G., and Heuer D. Oxidised zirconium: a potentially longer lasting hip implant. Mater Des 26 7 (2005) 618-622
    • (2005) Mater Des , vol.26 , Issue.7 , pp. 618-622
    • Good, V.1    Widding, K.2    Hunter, G.3    Heuer, D.4
  • 3
    • 15344345067 scopus 로고    scopus 로고
    • Design of a composite hip femoral prosthesis
    • Simoes J.A., and Marques A.T. Design of a composite hip femoral prosthesis. Mater Des 26 5 (2005) 391-401
    • (2005) Mater Des , vol.26 , Issue.5 , pp. 391-401
    • Simoes, J.A.1    Marques, A.T.2
  • 4
    • 0025981929 scopus 로고
    • An overview of implant materials
    • Simon J.P., and Fabry G. An overview of implant materials. Acta Orthop Belg 57 1 (1991) 1-5
    • (1991) Acta Orthop Belg , vol.57 , Issue.1 , pp. 1-5
    • Simon, J.P.1    Fabry, G.2
  • 5
    • 0027715365 scopus 로고
    • Failed innovation in total hip replacement: diagnosis and proposals for a cure
    • Huikes R. Failed innovation in total hip replacement: diagnosis and proposals for a cure. Acta Orthop Scand 64 4 (1993) 699-716
    • (1993) Acta Orthop Scand , vol.64 , Issue.4 , pp. 699-716
    • Huikes, R.1
  • 6
    • 0027711698 scopus 로고
    • Bio-deterioration and corrosion of metallic implants and prostheses
    • Lopez G.D. Bio-deterioration and corrosion of metallic implants and prostheses. Medicina (B Aires) 53 3 (1993) 260-274
    • (1993) Medicina (B Aires) , vol.53 , Issue.3 , pp. 260-274
    • Lopez, G.D.1
  • 7
    • 0030339091 scopus 로고    scopus 로고
    • Metal implants and surface reactions
    • Steinemann S.G. Metal implants and surface reactions. Injury 27 Suppl 3 (1996) SC16-SC22
    • (1996) Injury , vol.27 , Issue.SUPPL. 3
    • Steinemann, S.G.1
  • 8
    • 0035108321 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopaedic implants
    • Hallab N., Merritt K., and Jacobs J.J. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83A 3 (2001) 428-436
    • (2001) J Bone Joint Surg Am , vol.83 A , Issue.3 , pp. 428-436
    • Hallab, N.1    Merritt, K.2    Jacobs, J.J.3
  • 9
    • 25444508780 scopus 로고    scopus 로고
    • Wear and osteolysis in total joint replacements
    • Kadoya Y., Kobayashi A., and Ohashi H. Wear and osteolysis in total joint replacements. J Arthroplasty 12 8 (1997) 946-949
    • (1997) J Arthroplasty , vol.12 , Issue.8 , pp. 946-949
    • Kadoya, Y.1    Kobayashi, A.2    Ohashi, H.3
  • 10
    • 0031465283 scopus 로고    scopus 로고
    • Characteristics of metals used in implants
    • Gotman I. Characteristics of metals used in implants. J Endourol 11 6 (1997) 383-389
    • (1997) J Endourol , vol.11 , Issue.6 , pp. 383-389
    • Gotman, I.1
  • 11
    • 0027266764 scopus 로고
    • Polyethylene wear in total hip arthroplasty in patient-matched groups: a comparison of stainless steel, cobalt-chrome and titanium bearing surfaces
    • Brankston A.B., Faris P.M., Keating E.M., and Ritter M.A. Polyethylene wear in total hip arthroplasty in patient-matched groups: a comparison of stainless steel, cobalt-chrome and titanium bearing surfaces. J Arthroplasty 8 3 (1993) 315-322
    • (1993) J Arthroplasty , vol.8 , Issue.3 , pp. 315-322
    • Brankston, A.B.1    Faris, P.M.2    Keating, E.M.3    Ritter, M.A.4
  • 14
    • 0037828412 scopus 로고    scopus 로고
    • Designing of engineering components for optimal materials and manufacturing process utilisation
    • Edwards K.L. Designing of engineering components for optimal materials and manufacturing process utilisation. Mater Des 24 5 (2003) 355-366
    • (2003) Mater Des , vol.24 , Issue.5 , pp. 355-366
    • Edwards, K.L.1
  • 16
    • 15344346869 scopus 로고    scopus 로고
    • Selecting materials for optimum use in engineering components
    • Edwards K.L. Selecting materials for optimum use in engineering components. Mater Des 26 5 (2005) 469-473
    • (2005) Mater Des , vol.26 , Issue.5 , pp. 469-473
    • Edwards, K.L.1