메뉴 건너뛰기




Volumn 26, Issue 7, 2005, Pages 618-622

Oxidized zirconium: A potentially longer lasting hip implant

Author keywords

Non ferrous metals and alloys (A); Surface treatments (C); Wear (E)

Indexed keywords

ABRASION; CROSSLINKING; FRACTURE; ION IMPLANTATION; OXIDATION; POLYETHYLENES; PROSTHETICS; SURFACE TREATMENT;

EID: 18144366615     PISSN: 02613069     EISSN: 18734197     Source Type: Journal    
DOI: 10.1016/j.matdes.2004.08.014     Document Type: Article
Times cited : (50)

References (34)
  • 1
    • 0003711344 scopus 로고
    • John Charnley the man and the hip
    • London: Springer-Verlag
    • W. Waugh John Charnley the man and the hip 1990 Springer-Verlag London
    • (1990)
    • Waugh, W.1
  • 2
    • 0028214945 scopus 로고
    • Stanmore Total Hip Replacement A 15 to 16 year clinical and radiographic follow-up
    • R. Alsema R. Deutman T.J. Mulder Stanmore Total Hip Replacement A 15 to 16 year clinical and radiographic follow-up J. Bone Joint Surg. (Br) 76-B 1994 240-244
    • (1994) J. Bone Joint Surg. (Br) , vol.76 B , pp. 240-244
    • Alsema, R.1    Deutman, R.2    Mulder, T.J.3
  • 3
    • 0031894820 scopus 로고    scopus 로고
    • Average 12-year outcome of a chrome-cobalt, beaded, bony ingrowth acetabular component
    • S.E. Smith D.M. Estok W.H. Harris Average 12-year outcome of a chrome-cobalt, beaded, bony ingrowth acetabular component J Arthroplasty 13 1 1998 50-60
    • (1998) J. Arthroplasty , vol.13 , Issue.1 , pp. 50-60
    • Smith, S.E.1    Estok, D.M.2    Harris, W.H.3
  • 4
    • 84903398190 scopus 로고
    • Prognosis of total hip replacement results from the national register of revised failures 1979-1990 in Sweden - A ten year follow-up of 92,675 THR
    • Malchau H, Herberts P, Ahnfelt L, Johnell O. Prognosis of total hip replacement results from the national register of revised failures 1979-1990 in Sweden - a ten year follow-up of 92,675 THR. Am Acad Orthop Surg. 1993
    • (1993) Am. Acad. Orthop. Surg.
    • Malchau, H.1    Herberts, P.2    Ahnfelt, L.3    Johnell, O.4
  • 5
    • 0008500234 scopus 로고    scopus 로고
    • Prospects for alternate bearing surfaces in total replacement arthroplasty of the hip
    • Germany
    • Black J. Prospects for alternate bearing surfaces in total replacement arthroplasty of the hip. In: Proceedings of the 2nd symposium on ceramic wear couple. Germany; 1997
    • (1997) Proceedings of the 2nd Symposium on Ceramic Wear Couple
    • Black, J.1
  • 6
    • 84903395664 scopus 로고    scopus 로고
    • US 2nd ed., Chagrin Falls, OH: Knowledge Enterprises
    • The Ortho Factbook. US 2nd ed., Chagrin Falls, OH: Knowledge Enterprises; 2001
    • (2001) The Ortho. Factbook
  • 8
    • 0033922311 scopus 로고    scopus 로고
    • Wear of high-dose gamma-irradiated polyethylene in total hip replacement
    • H. Oonishi Y. Kadoya Wear of high-dose gamma-irradiated polyethylene in total hip replacement J Orthop Sci 5 3 2000 223-228
    • (2000) J. Orthop. Sci. , vol.5 , Issue.3 , pp. 223-228
    • Oonishi, H.1    Kadoya, Y.2
  • 9
    • 0032922181 scopus 로고    scopus 로고
    • Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene
    • B.M. Wroblewski P.D. Siney P.A. Fleming Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene J Bone Joint Surg 81B 1 1999 54-55
    • (1999) J. Bone Joint Surg. , vol.81 B , Issue.1 , pp. 54-55
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 12
    • 84903393621 scopus 로고    scopus 로고
    • Independent valuation of wear properties of commercially available cross linked UHMWPE
    • Soceity for Biomat
    • Furman BD, Bhattacharyya S, Hernoux C, Ranawat CS, Li S. Independent valuation of wear properties of commercially available cross linked UHMWPE. Soceity for Biomat 2001
    • (2001)
    • Furman, B.D.1    Bhattacharyya, S.2    Hernoux, C.3    Ranawat, C.S.4    Li, S.5
  • 15
    • 0242625426 scopus 로고    scopus 로고
    • Quantitative comparison of acetabular cup wear rates and femoral head damage in explanted charnley hip prostheses
    • Hailey, J.L., Ingham, E., Stone, M., Wroblewski, B. M. and Fisher J. Quantitative comparison of acetabular cup wear rates and femoral head damage in explanted charnley hip prostheses. Orthop Res Soc 1997
    • (1997) Orthop. Res. Soc.
    • Hailey, J.L.1    Ingham, E.2    Stone, M.3    Wroblewski, B.M.4    Fisher, J.5
  • 16
    • 0031256146 scopus 로고    scopus 로고
    • The Effect of Surface Topography of Retrieved Femoral on the wear of UHMWPE sockets
    • R.M. Hall P. Siney A. Unsworth Wroblewski The Effect of Surface Topography of Retrieved Femoral on the wear of UHMWPE sockets Med Eng Phys 9 8 1997 711-719
    • (1997) Med. Eng. Phys. , vol.9 , Issue.8 , pp. 711-719
    • Hall, R.M.1    Siney, P.2    Unsworth, A.3    Wroblewski4
  • 17
    • 0036928742 scopus 로고    scopus 로고
    • Analysis of retrieved uncemented porous-coated acetabular components in patients with and without pelvic osteolysis
    • R.L. Barrack F.P. Castro E.S. Szuszczewicz T.P. Schmalzried Analysis of retrieved uncemented porous-coated acetabular components in patients with and without pelvic osteolysis Orthopedics 25 12 2002 1373-1378
    • (2002) Orthopedics , vol.25 , Issue.12 , pp. 1373-1378
    • Barrack, R.L.1    Castro, F.P.2    Szuszczewicz, E.S.3    Schmalzried, T.P.4
  • 19
    • 0026974544 scopus 로고
    • Comparative wear studies of 28-mm ceramic and stainless steel total hip joints over 2 to 7 year period
    • H. Oonishi Y. Takayaka I.C. Clarke H. Jung Comparative wear studies of 28-mm ceramic and stainless steel total hip joints over 2 to 7 year period J Long-Term Eff Med 1 1 1992 37-47
    • (1992) J. Long-Term Eff. Med. , vol.1 , Issue.1 , pp. 37-47
    • Oonishi, H.1    Takayaka, Y.2    Clarke, I.C.3    Jung, H.4
  • 21
    • 0033781822 scopus 로고    scopus 로고
    • Ceramic femoral head retrieval data
    • G. Willmann Ceramic femoral head retrieval data Clin Orthop Relat R 79 2000 2-8
    • (2000) Clin. Orthop. Relat. R , vol.79 , pp. 2-8
    • Willmann, G.1
  • 22
    • 0036394796 scopus 로고    scopus 로고
    • Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions
    • M. Ries A. Salehi K. Widding G. Hunter Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions J Bone Joint Surg 4-A(S2) 2002 129-135
    • (2002) J. Bone Joint Surg. , vol.4 A , Issue.S2 , pp. 129-135
    • Ries, M.1    Salehi, A.2    Widding, K.3    Hunter, G.4
  • 23
    • 84903381888 scopus 로고    scopus 로고
    • Abrasive wear of oxidized Zr-2.5Nb, CoCrMo, and Ti-6Al-4V against bone cement
    • Hunter G, Long M. Abrasive wear of oxidized Zr-2.5Nb, CoCrMo, and Ti-6Al-4V against bone cement. Soc for Biomat 2000
    • (2000) Soc. for Biomat.
    • Hunter, G.1    Long, M.2
  • 24
    • 0032591366 scopus 로고    scopus 로고
    • Microstructural investigation of the oxide scale on Zr-2.5Nb and its interface with the alloy substrate
    • Neenan T, Marcolongo M, Valentini RF, editors. MRS Symp Proc; Materials Res. Soc
    • Benezra V, Mangin S, Treska M, Spector M, Hunter G, Hobbs L.W, Microstructural investigation of the oxide scale on Zr-2.5Nb and its interface with the alloy substrate, In: Neenan T, Marcolongo M, Valentini RF, editors. Biomedical Materials, MRS Symp Proc; vol. 550, Materials Res Soc; 1999. p. 337-42
    • (1999) Biomedical Materials , vol.550 , pp. 337-342
    • Benezra, V.1    Mangin, S.2    Treska, M.3    Spector, M.4    Hunter, G.5    Hobbs, L.W.6
  • 25
    • 84903387312 scopus 로고    scopus 로고
    • Adhesion testing of oxidized zirconium
    • Hunter, G. Adhesion testing of oxidized zirconium. Soc for Biomat 2001
    • (2001) Soc. for Biomat.
    • Hunter, G.1
  • 27
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • G. Bergmann F. Graichein A. Rohlmann Hip joint loading during walking and running, measured in two patients J Biomech 26 8 1993 969-990
    • (1993) J. Biomech. , vol.26 , Issue.8 , pp. 969-990
    • Bergmann, G.1    Graichein, F.2    Rohlmann, A.3
  • 28
    • 0006581415 scopus 로고    scopus 로고
    • Implants for surgery - Wear of total hip joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test
    • ISO 14242-1
    • ISO 14242-1, Implants for surgery - Wear of total hip joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test
  • 29
    • 1342347588 scopus 로고    scopus 로고
    • Quantification of third body damage, and its effect on UHMWPE wear with different types of femoral heads
    • Minakawa H, Stone M, Wroblewski BW, Ingham E, Fisher, J. Quantification of third body damage, and its effect on UHMWPE wear with different types of femoral heads. Orthop Res Soc [1997]
    • (1997) Orthop. Res. Soc.
    • Minakawa, H.1    Stone, M.2    Wroblewski, B.W.3    Ingham, E.4    Fisher, J.5
  • 31
    • 0028006356 scopus 로고
    • An indirect comparison of third-body wear in retrieved hydroxyapatite-coated porous and cemented femoral components
    • T.W. Bauer S.K. Taylor M. Jiang S.V. Medendorp An indirect comparison of third-body wear in retrieved hydroxyapatite-coated porous and cemented femoral components Clin Orthop 298 1994 11-18
    • (1994) Clin. Orthop. , vol.298 , pp. 11-18
    • Bauer, T.W.1    Taylor, S.K.2    Jiang, M.3    Medendorp, S.V.4
  • 32
    • 0032818125 scopus 로고    scopus 로고
    • The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement
    • A.P.D. Elfick R.M. Hall I.M. Pinder A. Unsworth The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement J Biomed Mater Res 48 1999 712-718
    • (1999) J. Biomed. Mater. Res. , vol.48 , pp. 712-718
    • Elfick, A.P.D.1    Hall, R.M.2    Pinder, I.M.3    Unsworth, A.4
  • 33
    • 33748675949 scopus 로고    scopus 로고
    • Wear performance of damaged oxidized Zr-2.5Nb modular femoral heads
    • Heuer D, Good V, Widding K. Wear performance of damaged oxidized Zr-2.5Nb modular femoral heads. Soc For Biomat 2003
    • (2003) Soc. For Biomat.
    • Heuer, D.1    Good, V.2    Widding, K.3
  • 34
    • 84903383050 scopus 로고    scopus 로고
    • Ceramic heads prevent run-away wear for crosslinked UHMWPE against 3rd body damage
    • Wang A, Schmidig G. Ceramic heads prevent run-away wear for crosslinked UHMWPE against 3rd body damage. Orthop Res Soc 2003
    • (2003) Orthop. Res. Soc.
    • Wang, A.1    Schmidig, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.