메뉴 건너뛰기




Volumn 28, Issue 9, 2007, Pages 1690-1692

3D rotational digital subtraction angiography may underestimate intracranial aneurysms: Findings from two basilar aneurysms

Author keywords

[No Author keywords available]

Indexed keywords

IOHEXOL;

EID: 35348936057     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A0652     Document Type: Article
Times cited : (40)

References (8)
  • 1
    • 0037931144 scopus 로고    scopus 로고
    • CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study
    • Piotin M, Gailloud P, Bidaut L, et al. CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study. Neuroradiology 2003;45:404-09
    • (2003) Neuroradiology , vol.45 , pp. 404-409
    • Piotin, M.1    Gailloud, P.2    Bidaut, L.3
  • 2
    • 0032466995 scopus 로고    scopus 로고
    • Second-generation three-dimensional reconstruction for rotational three-dimensional angiography
    • Bidaut LM, Laurent C, Piotin M, et al. Second-generation three-dimensional reconstruction for rotational three-dimensional angiography. Acad Radiol 1998;5:836-49
    • (1998) Acad Radiol , vol.5 , pp. 836-849
    • Bidaut, L.M.1    Laurent, C.2    Piotin, M.3
  • 3
    • 0347078305 scopus 로고    scopus 로고
    • Influence of geometric and hemodynamic parameters on aneurysm visualization during three-dimensional rotational angiography: An in vitro study
    • Ernemann UU, Gronewaller E, Duffner FB, et al. Influence of geometric and hemodynamic parameters on aneurysm visualization during three-dimensional rotational angiography: an in vitro study. AJNR Am J Neuroradiol 2003;24:597-603
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 597-603
    • Ernemann, U.U.1    Gronewaller, E.2    Duffner, F.B.3
  • 4
    • 21044431505 scopus 로고    scopus 로고
    • Quantitative evaluation of measurement accuracy for three-dimensional angiography system using various phantoms
    • Yamura M, Hirai T, Korogi Y, et al. Quantitative evaluation of measurement accuracy for three-dimensional angiography system using various phantoms. Radiat Med 2005;23:175-81
    • (2005) Radiat Med , vol.23 , pp. 175-181
    • Yamura, M.1    Hirai, T.2    Korogi, Y.3
  • 5
    • 33645743037 scopus 로고    scopus 로고
    • The utility of DynaCT in neuroendovascular procedures
    • Heran NS, Song JK, Namba K, et al. The utility of DynaCT in neuroendovascular procedures. AJNR Am J Neuroradiol 2006;27:330-32
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 330-332
    • Heran, N.S.1    Song, J.K.2    Namba, K.3
  • 6
    • 2442640381 scopus 로고    scopus 로고
    • The relationship between aneurysm volume, packing, and compaction in 145 coiled cerebral aneurysms
    • Sluzewski M, Rooij WJ, Slob MJ, et al. The relationship between aneurysm volume, packing, and compaction in 145 coiled cerebral aneurysms. Radiology 2004;231:653-58
    • (2004) Radiology , vol.231 , pp. 653-658
    • Sluzewski, M.1    Rooij, W.J.2    Slob, M.J.3
  • 7
    • 20044391646 scopus 로고    scopus 로고
    • Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries
    • Ford MD, Alperin N, Lee SH, et al. Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol Meas 2005;26:477-88
    • (2005) Physiol Meas , vol.26 , pp. 477-488
    • Ford, M.D.1    Alperin, N.2    Lee, S.H.3
  • 8
    • 21344435774 scopus 로고    scopus 로고
    • Contrast settling in cerebral aneurysm angiography
    • Wang Z-J, Hoffmann KR, Wang Z, et al. Contrast settling in cerebral aneurysm angiography. Phys Med Biol 2005;50:3171-81
    • (2005) Phys Med Biol , vol.50 , pp. 3171-3181
    • Wang, Z.-J.1    Hoffmann, K.R.2    Wang, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.