메뉴 건너뛰기




Volumn 127, Issue 2, 2007, Pages 525-530

Sensitive detection of antibody against antigen F1 of Yersinia pestis by an antigen sandwich method using a portable fiber optic biosensor

Author keywords

Antibody; Antigen F1; Fiber optic biosensor; Sandwich immunoassay; Yersinia pestis

Indexed keywords

ANTIGEN-ANTIBODY REACTIONS; CELL IMMOBILIZATION; ESCHERICHIA COLI; FIBER OPTIC SENSORS; MAMMALS;

EID: 35348933867     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2007.05.012     Document Type: Article
Times cited : (16)

References (23)
  • 1
    • 0031029062 scopus 로고    scopus 로고
    • Yersinia pestis-etiologic agent of plague
    • Perry R.D., and Fetherston J.D. Yersinia pestis-etiologic agent of plague. Clin. Microbiol. Rev. 10 1 (1997) 35-66
    • (1997) Clin. Microbiol. Rev. , vol.10 , Issue.1 , pp. 35-66
    • Perry, R.D.1    Fetherston, J.D.2
  • 2
    • 0028855209 scopus 로고
    • Plague in India: a new warning from an old nemesis
    • Campbell G.L., and Hughes J.M. Plague in India: a new warning from an old nemesis. Ann. Intern. Med. 122 2 (1995) 151-153
    • (1995) Ann. Intern. Med. , vol.122 , Issue.2 , pp. 151-153
    • Campbell, G.L.1    Hughes, J.M.2
  • 3
    • 0034692965 scopus 로고    scopus 로고
    • WHO, Human plague in 1998 and 1999, Weekly Epidemiological Record 75 (2000) 338-343.
  • 4
    • 0020424684 scopus 로고
    • Comparison of passive haemagglutination and enzyme-linked immunosorbent assay for serodiagnosis of plague
    • Williams J.E., Arntzen L., Robinson D.M., Cavanaugh D.C., and Isaacson M. Comparison of passive haemagglutination and enzyme-linked immunosorbent assay for serodiagnosis of plague. Bull World Health Organ 60 5 (1982) 777-781
    • (1982) Bull World Health Organ , vol.60 , Issue.5 , pp. 777-781
    • Williams, J.E.1    Arntzen, L.2    Robinson, D.M.3    Cavanaugh, D.C.4    Isaacson, M.5
  • 5
    • 18844445168 scopus 로고    scopus 로고
    • Direct determination of copper in urine using a sol-gel optical sensor coupled to a multicommutated flow system
    • Jeronimo P.C., Araujo A.N., Montenegro M.C., Pasquini C., and Raimundo Jr. I.M. Direct determination of copper in urine using a sol-gel optical sensor coupled to a multicommutated flow system. Anal. Bioanal. Chem. 380 1 (2004) 108-114
    • (2004) Anal. Bioanal. Chem. , vol.380 , Issue.1 , pp. 108-114
    • Jeronimo, P.C.1    Araujo, A.N.2    Montenegro, M.C.3    Pasquini, C.4    Raimundo Jr., I.M.5
  • 6
    • 2442597392 scopus 로고    scopus 로고
    • Evaluation of a standardized F1 capsular antigen capture ELISA test kit for the rapid diagnosis of plague
    • Splettstoesser W.D., Rahalison L., Grunow R., Neubauer H., and Chanteau S. Evaluation of a standardized F1 capsular antigen capture ELISA test kit for the rapid diagnosis of plague. FEMS Immunol. Med. Microbiol. 41 2 (2004) 149-155
    • (2004) FEMS Immunol. Med. Microbiol. , vol.41 , Issue.2 , pp. 149-155
    • Splettstoesser, W.D.1    Rahalison, L.2    Grunow, R.3    Neubauer, H.4    Chanteau, S.5
  • 7
    • 0004108112 scopus 로고    scopus 로고
    • Price C.P., and Newman D.J. (Eds), Macmillan Reference Ltd., London pp. 579-603
    • In: Price C.P., and Newman D.J. (Eds). Principles and Practice of Immunoassay (1997), Macmillan Reference Ltd., London pp. 579-603
    • (1997) Principles and Practice of Immunoassay
  • 8
    • 0027457622 scopus 로고
    • One-step competitive immunochromatographic assay for semiquantitative determination of lipoprotein(a) in plasma
    • Lou S.C., Patel C., Ching S., and Gordon J. One-step competitive immunochromatographic assay for semiquantitative determination of lipoprotein(a) in plasma. Clin. Chem. 39 4 (1993) 619-624
    • (1993) Clin. Chem. , vol.39 , Issue.4 , pp. 619-624
    • Lou, S.C.1    Patel, C.2    Ching, S.3    Gordon, J.4
  • 9
    • 0642312451 scopus 로고    scopus 로고
    • Serodiagnosis of plague in humans and rats using a rapid test
    • Thullier P., Guglielmo V., and Rajerison M.S.C. Serodiagnosis of plague in humans and rats using a rapid test. Am. J. Trop. Med. Hyp. 69 4 (2003) 450-451
    • (2003) Am. J. Trop. Med. Hyp. , vol.69 , Issue.4 , pp. 450-451
    • Thullier, P.1    Guglielmo, V.2    Rajerison, M.S.C.3
  • 11
    • 0030297496 scopus 로고    scopus 로고
    • Assay development for a portable fiberoptic biosensor
    • Anderson G.P., Breslin K.A., and Ligler F.S. Assay development for a portable fiberoptic biosensor. Asaio J. 42 6 (1996) 942-946
    • (1996) Asaio J. , vol.42 , Issue.6 , pp. 942-946
    • Anderson, G.P.1    Breslin, K.A.2    Ligler, F.S.3
  • 12
    • 0028796386 scopus 로고
    • Detection of Yersinia pestis fraction 1 antigen with a fiber optic biosensor
    • Cao L.K., Anderson G.P., Ligler F.S., and Ezzell J. Detection of Yersinia pestis fraction 1 antigen with a fiber optic biosensor. J. Clin. Microbiol. 33 2 (1995) 336-341
    • (1995) J. Clin. Microbiol. , vol.33 , Issue.2 , pp. 336-341
    • Cao, L.K.1    Anderson, G.P.2    Ligler, F.S.3    Ezzell, J.4
  • 14
    • 27744519033 scopus 로고    scopus 로고
    • Survey of the year 2004 commercial optical biosensor literature
    • Rich R.L., and Myszka D.G. Survey of the year 2004 commercial optical biosensor literature. J. Mol. Recognit. 18 6 (2005) 431-478
    • (2005) J. Mol. Recognit. , vol.18 , Issue.6 , pp. 431-478
    • Rich, R.L.1    Myszka, D.G.2
  • 18
    • 35348977197 scopus 로고    scopus 로고
    • H. Wei, Y. Zhao, Y. Bi, H. Liu, Z. Guo, Y. Song, J. Zhai, R. Yang, Direct detection of Yersinia pestis from the infected animal specimens by a fiber optic biosensor, Sens. Actuators: B Chem., 2006.
  • 19
    • 35348966865 scopus 로고    scopus 로고
    • Detection of Bacillus anthracis, Yersinia pestis and Staphylococcal Enterotoxin with a fiber optic biosensor (in Chinese)
    • Wei H., Jiang Y., Zhao Y., Bi Y., Guo Z., Zhai J., Song Y., Huang H., and Yang R. Detection of Bacillus anthracis, Yersinia pestis and Staphylococcal Enterotoxin with a fiber optic biosensor (in Chinese). Lett. Biotechnol. 17 (2006) 374-377
    • (2006) Lett. Biotechnol. , vol.17 , pp. 374-377
    • Wei, H.1    Jiang, Y.2    Zhao, Y.3    Bi, Y.4    Guo, Z.5    Zhai, J.6    Song, Y.7    Huang, H.8    Yang, R.9
  • 20
    • 0042904217 scopus 로고    scopus 로고
    • Fiber-optic evanescent wave biosensor and its application
    • (in Chinese)
    • Huijie H., Junhui Z., and Bingqiang R. Fiber-optic evanescent wave biosensor and its application. Acta Opt. Sin. 23 4 (2003) 451-454 (in Chinese)
    • (2003) Acta Opt. Sin. , vol.23 , Issue.4 , pp. 451-454
    • Huijie, H.1    Junhui, Z.2    Bingqiang, R.3
  • 21
    • 0026781370 scopus 로고
    • Characterization of monoclonal antibodies physically absorbed onto polystyrene latex particles
    • Van Erp R., Linders Y.E., Van sommeren A.P., and Gribnau T.C. Characterization of monoclonal antibodies physically absorbed onto polystyrene latex particles. J. Immunol. Methods 152 2 (1992) 191-199
    • (1992) J. Immunol. Methods , vol.152 , Issue.2 , pp. 191-199
    • Van Erp, R.1    Linders, Y.E.2    Van sommeren, A.P.3    Gribnau, T.C.4
  • 23
    • 0031003589 scopus 로고    scopus 로고
    • Effectiveness of protein A for antibody immobilization for a fiber optic biosensor
    • Anderson G.P., Jacoby M.A., Ligler F.S., and King K.D. Effectiveness of protein A for antibody immobilization for a fiber optic biosensor. Biosens. Bioelectron. 12 4 (1997) 329-336
    • (1997) Biosens. Bioelectron. , vol.12 , Issue.4 , pp. 329-336
    • Anderson, G.P.1    Jacoby, M.A.2    Ligler, F.S.3    King, K.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.