메뉴 건너뛰기




Volumn 34, Issue 11, 2007, Pages 985-990

Volumetric analysis of extraction sockets using cone beam computed tomography: A pilot study on ex vivo jaw bone

Author keywords

Bone volume; Cone beam CT; Jaw; Tooth socket; Volumetry

Indexed keywords

ARTICLE; CONE BEAM COMPUTED TOMOGRAPHY; EVALUATION; HISTOLOGY; HUMAN; IMAGE PROCESSING; MANDIBLE; MAXILLA; PILOT STUDY; TOOTH SOCKET;

EID: 35348821814     PISSN: 03036979     EISSN: 1600051X     Source Type: Journal    
DOI: 10.1111/j.1600-051X.2007.01134.x     Document Type: Article
Times cited : (56)

References (38)
  • 2
    • 4143136222 scopus 로고    scopus 로고
    • Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): System configuration and physical properties
    • Araki, K., Maki, K., Seki, K., Sakamaki, K., Harata, Y., Sakaino, R., Okano, T. Seo, K. (2004) Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): system configuration and physical properties. Dentomaxillofacial Radiology 33, 51 59.
    • (2004) Dentomaxillofacial Radiology , vol.33 , pp. 51-59
    • Araki, K.1    Maki, K.2    Seki, K.3    Sakamaki, K.4    Harata, Y.5    Sakaino, R.6    Okano, T.7    Seo, K.8
  • 4
    • 0031994476 scopus 로고    scopus 로고
    • Volumetric changes following barrier regeneration procedures for the surgical management of grade II molar furcation defects in baboons: II. Bone, cementum, epithelium, and connective tissue
    • Butler, J. R., Rajnay, Z. W., Vernino, A. R. Parker, D. (1998) Volumetric changes following barrier regeneration procedures for the surgical management of grade II molar furcation defects in baboons: II. Bone, cementum, epithelium, and connective tissue. International Journal of Periodontics and Restorative Dentistry 18, 58 69.
    • (1998) International Journal of Periodontics and Restorative Dentistry , vol.18 , pp. 58-69
    • Butler, J.R.1    Rajnay, Z.W.2    Vernino, A.R.3    Parker, D.4
  • 7
    • 1842435166 scopus 로고    scopus 로고
    • Quantitative assessment of post-extraction healing and alveolar ridge remodelling of the mandible in female rats
    • Elsubeihi, E. S. Heersche, J. N. (2004) Quantitative assessment of post-extraction healing and alveolar ridge remodelling of the mandible in female rats. Archives of Oral Biology 49, 401 412.
    • (2004) Archives of Oral Biology , vol.49 , pp. 401-412
    • Elsubeihi, E.S.1    Heersche, J.N.2
  • 10
    • 33745791393 scopus 로고    scopus 로고
    • Comparison of image performance between cone-beam computed tomography for dental use and four-row multidetector helical CT
    • Hashimoto, K., Kawashima, S., Araki, M., Iwai, K., Sawada, K. Akiyama, Y. (2006) Comparison of image performance between cone-beam computed tomography for dental use and four-row multidetector helical CT. Journal of Oral Science 48, 27 34.
    • (2006) Journal of Oral Science , vol.48 , pp. 27-34
    • Hashimoto, K.1    Kawashima, S.2    Araki, M.3    Iwai, K.4    Sawada, K.5    Akiyama, Y.6
  • 12
    • 7044253361 scopus 로고    scopus 로고
    • Postoperative imaging of zygomaticomaxillary complex fractures using digital volume tomography
    • Heiland, M., Schulze, D., Rother, U. Schmelzle, R. (2004) Postoperative imaging of zygomaticomaxillary complex fractures using digital volume tomography. Journal of Oral and Maxillofacial Surgery 62, 1387 1391.
    • (2004) Journal of Oral and Maxillofacial Surgery , vol.62 , pp. 1387-1391
    • Heiland, M.1    Schulze, D.2    Rother, U.3    Schmelzle, R.4
  • 13
    • 29144465753 scopus 로고    scopus 로고
    • Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography
    • Hilgers, M. L., Scarfe, W. C., Scheetz, J. P. Farman, A. G. (2005) Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography. American Journal of Orthodontics and Dentofacial Orthopedics 128, 803 811.
    • (2005) American Journal of Orthodontics and Dentofacial Orthopedics , vol.128 , pp. 803-811
    • Hilgers, M.L.1    Scarfe, W.C.2    Scheetz, J.P.3    Farman, A.G.4
  • 15
    • 14044259241 scopus 로고    scopus 로고
    • Evaluation of the usefulness of the limited cone-beam CT (3DX) in the assessment of the thickness of the roof of the glenoid fossa of the temporomandibular joint
    • Honda, K., Arai, Y., Kashima, M., Takano, Y., Sawada, K., Ejima, K. Iwai, K. (2004) Evaluation of the usefulness of the limited cone-beam CT (3DX) in the assessment of the thickness of the roof of the glenoid fossa of the temporomandibular joint. Dentomaxillofacial Radiology 33, 391 395.
    • (2004) Dentomaxillofacial Radiology , vol.33 , pp. 391-395
    • Honda, K.1    Arai, Y.2    Kashima, M.3    Takano, Y.4    Sawada, K.5    Ejima, K.6    Iwai, K.7
  • 16
    • 0031605361 scopus 로고    scopus 로고
    • Volumetry of bone grafts by three-dimensional computed tomographic reconstruction: An animal study in the minipig
    • Jensen, J., Kragskov, J., Wenzel, A. Sindet-Pedersen, S. (1998) Volumetry of bone grafts by three-dimensional computed tomographic reconstruction: an animal study in the minipig. Dentomaxillofacial Radiology 27, 41 44.
    • (1998) Dentomaxillofacial Radiology , vol.27 , pp. 41-44
    • Jensen, J.1    Kragskov, J.2    Wenzel, A.3    Sindet-Pedersen, S.4
  • 17
    • 14244264415 scopus 로고    scopus 로고
    • Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
    • Lascala, C. A., Panella, J. Marques, M. M. (2004) Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofacial Radiology 33, 291 294.
    • (2004) Dentomaxillofacial Radiology , vol.33 , pp. 291-294
    • Lascala, C.A.1    Panella, J.2    Marques, M.M.3
  • 22
    • 0642334597 scopus 로고    scopus 로고
    • Computer-assisted simulations in orthodontic diagnosis and the application of a new cone beam X-ray computed tomography
    • discussion 179-182.
    • Maki, K., Inou, N., Takanishi, A. Miller, A. J. (2003) Computer-assisted simulations in orthodontic diagnosis and the application of a new cone beam X-ray computed tomography. Orthodontics and Craniofacial Research 6 (Suppl. 1), 95 101, discussion 179-182.
    • (2003) Orthodontics and Craniofacial Research , vol.6 , Issue.SUPPL. 1 , pp. 95-101
    • Maki, K.1    Inou, N.2    Takanishi, A.3    Miller, A.J.4
  • 23
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results
    • Mozzo, P., Procacci, C., Tacconi, A., Martini, P. T. Andreis, I. A. (1998) A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. European Radiology 8, 1558 1564.
    • (1998) European Radiology , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreis, I.A.5
  • 28
    • 0031196752 scopus 로고    scopus 로고
    • Volumetric changes following barrier regeneration procedures for the surgical management of grade II molar furcation defects in baboons: I. Overall defect fill
    • Rajnay, Z. W., Butler, J. R., Vernino, A. R. Parker, D. E. (1997) Volumetric changes following barrier regeneration procedures for the surgical management of grade II molar furcation defects in baboons: I. Overall defect fill. International Journal of Periodontics and Restorative Dentistry 17, 378 391.
    • (1997) International Journal of Periodontics and Restorative Dentistry , vol.17 , pp. 378-391
    • Rajnay, Z.W.1    Butler, J.R.2    Vernino, A.R.3    Parker, D.E.4
  • 29
    • 13944281399 scopus 로고    scopus 로고
    • Low-dose dental computed tomography: Significant dose reduction without loss of image quality
    • Rustemeyer, P., Streubuhr, U. Suttmoeller, J. (2004) Low-dose dental computed tomography: significant dose reduction without loss of image quality. Acta Radiologica 45, 847 853.
    • (2004) Acta Radiologica , vol.45 , pp. 847-853
    • Rustemeyer, P.1    Streubuhr, U.2    Suttmoeller, J.3
  • 30
    • 3042557818 scopus 로고    scopus 로고
    • Clinical application of a new cone-beam computerized tomography system to assess multiple two-dimensional images for the preoperative treatment planning of maxillary implants: Case reports
    • Sato, S., Arai, Y., Shinoda, K. Ito, K. (2004) Clinical application of a new cone-beam computerized tomography system to assess multiple two-dimensional images for the preoperative treatment planning of maxillary implants: case reports. Quintessence International 35, 525 528.
    • (2004) Quintessence International , vol.35 , pp. 525-528
    • Sato, S.1    Arai, Y.2    Shinoda, K.3    Ito, K.4
  • 33
    • 0035110308 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of X-ray scatter
    • Siewerdsen, J. H. Jaffray, D. A. (2001) Cone-beam computed tomography with a flat-panel imager: magnitude and effects of X-ray scatter. Medical Physics 28, 220 231.
    • (2001) Medical Physics , vol.28 , pp. 220-231
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 34
    • 0032600406 scopus 로고    scopus 로고
    • Use of intraoperative computed tomography during repair of orbitozygomatic fractures
    • Stanley, R. B. Jr. (1999) Use of intraoperative computed tomography during repair of orbitozygomatic fractures. Archives of Facial Plastic Surgery 1, 19 24.
    • (1999) Archives of Facial Plastic Surgery , vol.1 , pp. 19-24
    • Stanley Jr., R.B.1
  • 35
    • 0642365211 scopus 로고    scopus 로고
    • Cone beam computed tomography in craniofacial imaging
    • discussion 179-182
    • Sukovic, P. (2003) Cone beam computed tomography in craniofacial imaging. Orthodontics and Craniofacial Research 6 (Suppl. 1), 31 36, discussion 179-182.
    • (2003) Orthodontics and Craniofacial Research , vol.6 , Issue.SUPPL. 1 , pp. 31-36
    • Sukovic, P.1
  • 36
    • 7944227238 scopus 로고    scopus 로고
    • Radiographic examination of the temporomandibular joint using cone beam computed tomography
    • Tsiklakis, K., Syriopoulos, K. Stamatakis, H. C. (2004) Radiographic examination of the temporomandibular joint using cone beam computed tomography. Dentomaxillofacial Radiology 33, 196 201.
    • (2004) Dentomaxillofacial Radiology , vol.33 , pp. 196-201
    • Tsiklakis, K.1    Syriopoulos, K.2    Stamatakis, H.C.3
  • 38
    • 0036490726 scopus 로고    scopus 로고
    • Clinical indications for digital volume tomography in oral and maxillofacial surgery
    • Ziegler, C. M., Woertche, R., Brief, J. Hassfeld, S. (2002) Clinical indications for digital volume tomography in oral and maxillofacial surgery. Dentomaxillofacial Radiology 31, 126 130.
    • (2002) Dentomaxillofacial Radiology , vol.31 , pp. 126-130
    • Ziegler, C.M.1    Woertche, R.2    Brief, J.3    Hassfeld, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.