Volumn 6510, Issue PART 1, 2007, Pages

Optimization of a CR system comprising line-scanning and needle image plate technology with respect to examinations of extremities

Author keywords

Computed radiography; Image quality; Line scanning; Needle image plate; Scanhead

Indexed keywords

LIGHT SOURCES; MEDICAL IMAGING; NATURAL FREQUENCIES; OPTICAL RESOLVING POWER; OPTICAL TRANSFER FUNCTION;

EID: 35148885822     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.708368     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 1
    • 0037038876 scopus 로고    scopus 로고
    • The physics of Computed Radiography
    • J. A. Rowlands, "The physics of Computed Radiography", Phys. Med. Biol. 47, 123-166 (2002)
    • (2002) Phys. Med. Biol , vol.47 , pp. 123-166
    • Rowlands, J.A.1
  • 2
    • 0034516219 scopus 로고    scopus 로고
    • Image Quality evaluation of a desktop computed radiography system
    • K. A. Fetterly and N. J. Hangiandreou, "Image Quality evaluation of a desktop computed radiography system", Med. Phys. 27, 2669-2679 (2000)
    • (2000) Med. Phys , vol.27 , pp. 2669-2679
    • Fetterly, K.A.1    Hangiandreou, N.J.2
  • 4
    • 28044467731 scopus 로고    scopus 로고
    • Initial clinical results with a new needle screen storage phosphor system in chest radiograms
    • M. Koerner, S. Wirth, M. Treitl, M. Reiser, K.-J. Pfeifer, "Initial clinical results with a new needle screen storage phosphor system in chest radiograms", Rofo. 177(11), 1491-1496 (2005)
    • (2005) Rofo , vol.177 , Issue.11 , pp. 1491-1496
    • Koerner, M.1    Wirth, S.2    Treitl, M.3    Reiser, M.4    Pfeifer, K.-J.5
  • 5
    • 0003696431 scopus 로고
    • Medical diagnostic x-ray equipment - Radiation conditions for use in the determination of characteristics
    • IEC 61267:, International Electrotechnical Commission IEC, Geneva, Switzerland
    • IEC 61267: Medical diagnostic x-ray equipment - Radiation conditions for use in the determination of characteristics, International Electrotechnical Commission (IEC), Geneva, Switzerland, 1994.
    • (1994)
  • 6
    • 0041403557 scopus 로고    scopus 로고
    • Medical electrical equipment - Characteristics of digital x-ray imaging devices - Part 1: Determination of the detective quantum efficiency
    • IEC 62220-1:, International Electrotechnical Commission IEC, Geneva, Switzerland
    • IEC 62220-1: Medical electrical equipment - Characteristics of digital x-ray imaging devices - Part 1: Determination of the detective quantum efficiency, International Electrotechnical Commission (IEC), Geneva, Switzerland, 2003.
    • (2003)
  • 7
    • 35148839067 scopus 로고    scopus 로고
    • M. Koerner, M. Treitl, U. Linsenmaier, K.J. Pfeifer, M. Reiser, Dose Reduction in Digital Radiography: Comparison of Needle-Structured Storage Phosphors, Powder-Structured Storage Phosphors and a Flat-Panel Detector at Different Dose Levels, presentation # SSM 17-04, RSNA 2004
    • M. Koerner, M. Treitl, U. Linsenmaier, K.J. Pfeifer, M. Reiser, "Dose Reduction in Digital Radiography: Comparison of Needle-Structured Storage Phosphors, Powder-Structured Storage Phosphors and a Flat-Panel Detector at Different Dose Levels", presentation # SSM 17-04, RSNA 2004
  • 8
    • 0036033697 scopus 로고    scopus 로고
    • New high-speed scanning technique for Computed Radiography
    • R. Schaetzing, R. Fasbender, P. Kersten, "New high-speed scanning technique for Computed Radiography", Proc. SPIE 4682, 511-520 (2002)
    • (2002) Proc. SPIE , vol.4682 , pp. 511-520
    • Schaetzing, R.1    Fasbender, R.2    Kersten, P.3
  • 9
    • 35148832145 scopus 로고    scopus 로고
    • Agfa-Gevaert Patent EP1482328, US 7122822
    • Agfa-Gevaert Patent EP1482328, US 7122822
  • 10
    • 35148894544 scopus 로고    scopus 로고
    • Agfa-Gevaert Patent EP 1298458
    • Agfa-Gevaert Patent EP 1298458
  • 11
    • 23844489226 scopus 로고    scopus 로고
    • Reflective and transmissive CR ScanHead technology on needle image plates
    • J. Frankenberger, S.Mair, C. Herrmann, J. Lamotte, R. Fasbender, "Reflective and transmissive CR ScanHead technology on needle image plates", Proc. SPIE 5745, 499-510, (2005)
    • (2005) Proc. SPIE , vol.5745 , pp. 499-510
    • Frankenberger, J.1    Mair, S.2    Herrmann, C.3    Lamotte, J.4    Fasbender, R.5
  • 12
    • 0024612751 scopus 로고
    • Visuelle Auswertung von Rasterbildern
    • D. Hoeschen, G. He: "Visuelle Auswertung von Rasterbildern", PTB-Mitteilungen 99, 10-14 (1989)
    • (1989) PTB-Mitteilungen , vol.99 , pp. 10-14
    • Hoeschen, D.1    He, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.