메뉴 건너뛰기




Volumn 6509, Issue PART 2, 2007, Pages

Statistical characterization of C-arm distortion with application to intra-operative distortion correction

Author keywords

Distortion; Eigen modes; Intra operative distortion correction; Principal component analysis

Indexed keywords

IMAGE ANALYSIS; IMAGE RECONSTRUCTION; MEDICAL IMAGING; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 35148867224     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.711605     Document Type: Conference Paper
Times cited : (9)

References (9)
  • 1
    • 0030742408 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a c-arm mounted xrii: Correction of image intensifier distortion
    • R. Fahrig, M. Moreau, and D.W. Holdsworth, "Three-dimensional computed tomographic reconstruction using a c-arm mounted xrii: correction of image intensifier distortion," Med Phys, vol. 24(7), pp. 1097-106, 1997.
    • (1997) Med Phys , vol.24 , Issue.7 , pp. 1097-1106
    • Fahrig, R.1    Moreau, M.2    Holdsworth, D.W.3
  • 3
    • 84944077375 scopus 로고    scopus 로고
    • Robust automatic c-arm calibration for fluoroscopy-based navigation: A practical approach
    • H. Livyatan, Z. Yaniv, and L. Joskowicz, "Robust automatic c-arm calibration for fluoroscopy-based navigation: A practical approach," in MICCAI, 2002, vol. 2489, pp. 60-68.
    • (2002) MICCAI , vol.2489 , pp. 60-68
    • Livyatan, H.1    Yaniv, Z.2    Joskowicz, L.3
  • 5
    • 84956647161 scopus 로고    scopus 로고
    • S. Schreiner, J.H. Anderson, R.H. Taylor, J. Funda, A.Bzostek, and A.C. Barnes, A system for percutaneous delivery of treatment with a fluoroscopically-guided robot, in In Troccaz J, Grimson E, Mosges R, editors: Proceedings of First Joint Conference on Computer Vision, Virtual Reality and Robotics in Medicine and Medical Robotics and Computer Assisted Surgery (CVRMed-MRCAS' 97), Grenoble, France, March 1997, 1997, pp. 747-756.
    • S. Schreiner, J.H. Anderson, R.H. Taylor, J. Funda, A.Bzostek, and A.C. Barnes, "A system for percutaneous delivery of treatment with a fluoroscopically-guided robot," in In Troccaz J, Grimson E, Mosges R, editors: Proceedings of First Joint Conference on Computer Vision, Virtual Reality and Robotics in Medicine and Medical Robotics and Computer Assisted Surgery (CVRMed-MRCAS' 97), Grenoble, France, March 1997, 1997, pp. 747-756.
  • 7
    • 0029463591 scopus 로고
    • Correction for image intensifier distortion for three-dimensional x-ray angiography
    • B. Schueler and X. Hu, "Correction for image intensifier distortion for three-dimensional x-ray angiography," in Proc. of SPIE, Medical Imaging 1995, 1995, vol. 2432, pp. 272-279.
    • (1995) Proc. of SPIE, Medical Imaging 1995 , vol.2432 , pp. 272-279
    • Schueler, B.1    Hu, X.2
  • 9
    • 0025907199 scopus 로고
    • Analysis and correction of imperfections in the image intensifier-tv-digitizer imaging chain
    • Boone J.M., Seibert J.A., Barrett W.A., and Blood E.A., "Analysis and correction of imperfections in the image intensifier-tv-digitizer imaging chain," Med Phys, vol. 18, pp. 236-242, 1991.
    • (1991) Med Phys , vol.18 , pp. 236-242
    • Boone, J.M.1    Seibert, J.A.2    Barrett, W.A.3    Blood, E.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.