메뉴 건너뛰기




Volumn 6509, Issue PART 1, 2007, Pages

A computer-controlled pump and realistic, anthropomorphic respiratory phantom for validating image-guided systems

Author keywords

Abdominal procedures; Image guided therapy; Medical robotics; Respiratory motion; Surgical simulation; Validation

Indexed keywords

ABDOMINAL PROCEDURES; IMAGE-GUIDED THERAPY; RESPIRATORY MOTION; SURGICAL SIMULATION;

EID: 35148848988     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.712226     Document Type: Conference Paper
Times cited : (8)

References (12)
  • 1
    • 0036060410 scopus 로고    scopus 로고
    • Cleary K, Banovac F, Levy E, and Tanaka D, Development of a liver respiratory motion simulator to investigate magnetic tracking for abdominal interventions. Proc. SPIE 4681, p. 25-29, Medical Imaging 2002: Visualization, Image-Guided Procedures, and Display, Seong K. Mun; Ed.
    • Cleary K, Banovac F, Levy E, and Tanaka D, "Development of a liver respiratory motion simulator to investigate magnetic tracking for abdominal interventions." Proc. SPIE Vol. 4681, p. 25-29, Medical Imaging 2002: Visualization, Image-Guided Procedures, and Display, Seong K. Mun; Ed.
  • 3
    • 0004010864 scopus 로고    scopus 로고
    • Development and Application of the New Dynamic NURBS-based Cardiac-Torso (NCAT) Phantom
    • PhD dissertation, University of North Carolina-Chapel Hill, Department of Biomedical Engineering
    • Segars W. "Development and Application of the New Dynamic NURBS-based Cardiac-Torso (NCAT) Phantom." PhD dissertation, University of North Carolina-Chapel Hill, Department of Biomedical Engineering, 2001.
    • (2001)
    • Segars, W.1
  • 4
    • 32544434092 scopus 로고    scopus 로고
    • Motion correction for improved target localization with on-board cone-beam computed tomography
    • Jan 21;
    • Li T, Schreibmann E, Yang Y, and Xing L. "Motion correction for improved target localization with on-board cone-beam computed tomography." Phys Med Biol. 2006 Jan 21;51(2):253-67.
    • (2006) Phys Med Biol , vol.51 , Issue.2 , pp. 253-267
    • Li, T.1    Schreibmann, E.2    Yang, Y.3    Xing, L.4
  • 5
    • 17844379967 scopus 로고    scopus 로고
    • Respiratory correlated cone beam CT
    • Apr;
    • Sonke JJ, Zijp L, Remeijer P, and van Herk M. "Respiratory correlated cone beam CT." Med Phys. 2005 Apr;32(4):1176-86.
    • (2005) Med Phys , vol.32 , Issue.4 , pp. 1176-1186
    • Sonke, J.J.1    Zijp, L.2    Remeijer, P.3    van Herk, M.4
  • 6
    • 33748290300 scopus 로고    scopus 로고
    • Novel lung IMRT planning algorithms with nonuniform dose delivery strategy to account for respiratory motion
    • Sep;
    • Li X, Zhang P, Mah D, Gewanter R, and Kutcher G. "Novel lung IMRT planning algorithms with nonuniform dose delivery strategy to account for respiratory motion." Med Phys. 2006 Sep;33(9):3390-8.
    • (2006) Med Phys , vol.33 , Issue.9 , pp. 3390-3398
    • Li, X.1    Zhang, P.2    Mah, D.3    Gewanter, R.4    Kutcher, G.5
  • 7
    • 7244242297 scopus 로고    scopus 로고
    • Respiration tracking in radiosurgery
    • Oct;
    • Schweikard A, Shiomi H, and Adler J. "Respiration tracking in radiosurgery." Med Phys. 2004 Oct;31(10):2738-41.
    • (2004) Med Phys , vol.31 , Issue.10 , pp. 2738-2741
    • Schweikard, A.1    Shiomi, H.2    Adler, J.3
  • 8
    • 0032844267 scopus 로고    scopus 로고
    • Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    • Hanley J et al. "Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation." Int. J. Radiat. Oncol. Biol. Phys. (1999)45:603-11.
    • (1999) Int. J. Radiat. Oncol. Biol. Phys , vol.45 , pp. 603-611
    • Hanley, J.1
  • 11
    • 0034333029 scopus 로고    scopus 로고
    • Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    • Shirato H et al. "Physical aspects of a real-time tumor-tracking system for gated radiotherapy." Int. J. Radiat. Oncol. Biol. Phys. (2000) 48:1187-95.
    • (2000) Int. J. Radiat. Oncol. Biol. Phys , vol.48 , pp. 1187-1195
    • Shirato, H.1
  • 12
    • 34247532042 scopus 로고    scopus 로고
    • Population and patient-specific target margins for 4D adaptive radiotherapy to account for intra- and inter-fraction variation in lung tumour position
    • Hugo GD, Yan D, and Liang J. "Population and patient-specific target margins for 4D adaptive radiotherapy to account for intra- and inter-fraction variation in lung tumour position." Phys. Med. Biol. 52 (2007) 257-274.
    • (2007) Phys. Med. Biol , vol.52 , pp. 257-274
    • Hugo, G.D.1    Yan, D.2    Liang, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.