메뉴 건너뛰기




Volumn 6510, Issue PART 2, 2007, Pages

Amplified pixel sensor architectures for low dose computed tomography using silicon thin film technology

Author keywords

Amorphous silicon; Amplified pixel sensor; Cone beam computed tomography; Flat panel imager; High frame rate; Medical imaging; Pixel architecture; TFT

Indexed keywords

AMORPHOUS SILICON; AMPLIFICATION; COMPUTERIZED TOMOGRAPHY; DOSIMETRY; IMAGE ANALYSIS; MEDICAL IMAGING; PIXELS; THIN FILMS;

EID: 35148848797     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.710147     Document Type: Conference Paper
Times cited : (5)

References (9)
  • 1
    • 33745369450 scopus 로고    scopus 로고
    • Flat panel detector-based cone beam CT for dynamic imaging: System evaluation
    • R. Ning, D. Conover, Y. Yu, Y. Zhang, W.Cai, D. Yang, and X. Lu, "Flat panel detector-based cone beam CT for dynamic imaging: system evaluation", Proceedings of the SPIE, Volume 6142, pp. 808-814 (2006).
    • (2006) Proceedings of the SPIE , vol.6142 , pp. 808-814
    • Ning, R.1    Conover, D.2    Yu, Y.3    Zhang, Y.4    Cai, W.5    Yang, D.6    Lu, X.7
  • 2
    • 23844442620 scopus 로고    scopus 로고
    • Physical evaluation of a high-frame-rate extended dynamic range flat panel detector for real-time cone beam computed tomography applications
    • S.J. Boyce, A. Chawla, and E. Samei, "Physical evaluation of a high-frame-rate extended dynamic range flat panel detector for real-time cone beam computed tomography applications", Proceedings of the SPIE, Volume 5745, pp. 591-599 (2005).
    • (2005) Proceedings of the SPIE , vol.5745 , pp. 591-599
    • Boyce, S.J.1    Chawla, A.2    Samei, E.3
  • 3
    • 33744809045 scopus 로고    scopus 로고
    • T. Xu , J.L. Ducote , J.T. Wong, and S. Molloi, Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification, Med Phys., 33, pp. 1612-16122, 16872069 (2006).
    • T. Xu , J.L. Ducote , J.T. Wong, and S. Molloi, "Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification", Med Phys., vol. 33, pp. 1612-16122, 16872069 (2006).
  • 5
    • 0034874445 scopus 로고    scopus 로고
    • Alternate pixel architectures for large-area medical imaging
    • K.S. Karim, A. Nathan, J.A. Rowlands, "Alternate pixel architectures for large-area medical imaging", Proceedings of the SPIE, Volume 4320, pp. 35-46 (2001).
    • (2001) Proceedings of the SPIE , vol.4320 , pp. 35-46
    • Karim, K.S.1    Nathan, A.2    Rowlands, J.A.3
  • 6
    • 33745402764 scopus 로고    scopus 로고
    • Low-Noise Pixel Architectures for Advanced Diagnostic Medical X-ray Imaging Applications
    • March
    • M.H. Izadi, K.S. Karim, A. Nathan, J.A. Rowlands, "Low-Noise Pixel Architectures for Advanced Diagnostic Medical X-ray Imaging Applications," Proceedings of the SPIE, Volume 6142, March 2006.
    • (2006) Proceedings of the SPIE , vol.6142
    • Izadi, M.H.1    Karim, K.S.2    Nathan, A.3    Rowlands, J.A.4
  • 7
    • 35148894989 scopus 로고    scopus 로고
    • High Dynamic Range 2-TFT Amplified Pixel Sensor Architecture for Digital Mammography Tomosynthesis
    • press
    • F. Taghibakhsh and K.S. Karim, "High Dynamic Range 2-TFT Amplified Pixel Sensor Architecture for Digital Mammography Tomosynthesis', IET proceedings on Circuits, Devices and Systems, June 2006, in press.
    • (2006) IET proceedings on Circuits, Devices and Systems, June
    • Taghibakhsh, F.1    Karim, K.S.2
  • 8
    • 33646689592 scopus 로고    scopus 로고
    • Low leakage a-Si:H thin film transistors deposited on glass substrates using hotwire chemical vapor deposition
    • F. Taghibakhsh and K.S. Karim, "Low leakage a-Si:H thin film transistors deposited on glass substrates using hotwire chemical vapor deposition", Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films, Volume 24, Issue 3, pp. 866-868 (2006).
    • (2006) Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films , vol.24 , Issue.3 , pp. 866-868
    • Taghibakhsh, F.1    Karim, K.S.2
  • 9
    • 3142563295 scopus 로고    scopus 로고
    • Noise performance of a current-mediated amplified pixel for medical imaging
    • K.S. Karim and A. Nathan, 'Noise performance of a current-mediated amplified pixel for medical imaging', Journal of Vacuum Science and Technology A, Volume 22, pp. 1010-1014 (2004).
    • (2004) Journal of Vacuum Science and Technology A , vol.22 , pp. 1010-1014
    • Karim, K.S.1    Nathan, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.