메뉴 건너뛰기




Volumn 5745, Issue I, 2005, Pages 591-599

Physical evaluation of a high frame rate, extended dynamic range flat panel detector for real-time cone beam computed tomography applications

Author keywords

Angiography; Computed tomography; Detective quantum efficiency; Flat panel detector; Lag; Modulation transfer function; Noise power spectrum; Temporal MTF

Indexed keywords

DETECTIVE QUANTUM EFFICIENCY; FLAT PANEL DETECTORS (FPD); LAG; MODULATION TRANSFER FUNCTIONS; NOISE POWER SPECTRUM; TEMPORAL MTF;

EID: 23844442620     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.593881     Document Type: Conference Paper
Times cited : (7)

References (12)
  • 1
    • 0033623770 scopus 로고    scopus 로고
    • Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographie imaging applications
    • P. R. Granfors and R. Aufrichtig, "Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographie imaging applications," Med Phys 27, 1324-31 (2000).
    • (2000) Med Phys , vol.27 , pp. 1324-1331
    • Granfors, P.R.1    Aufrichtig, R.2
  • 7
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographie systems using an edge test device
    • E. Samei, M. J. Flynn and D. A. Reimann, "A method for measuring the presampled MTF of digital radiographie systems using an edge test device," Med Phys 25, 102-113 (1998).
    • (1998) Med Phys , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 8
    • 0041461316 scopus 로고    scopus 로고
    • A method for modifying the image quality parameters of digital radiographie images
    • R. S. Saunders and E. Samei, "A method for modifying the image quality parameters of digital radiographie images," Med Phys 30, 3006-3017 (2003).
    • (2003) Med Phys , vol.30 , pp. 3006-3017
    • Saunders, R.S.1    Samei, E.2
  • 9
    • 0033740285 scopus 로고    scopus 로고
    • DQE(f) of an amorphous silicon flat panel X-ray detector: Detector parameter influences and measurement methodology
    • P. R. Granfors and R. Aufrichtig, "DQE(f) of an amorphous silicon flat panel X-ray detector: detector parameter influences and measurement methodology," Proc. SPIE 3977, 2-13 (2000).
    • (2000) Proc. SPIE , vol.3977 , pp. 2-13
    • Granfors, P.R.1    Aufrichtig, R.2
  • 10
    • 0000979064 scopus 로고
    • The equivalent quantum efficiency of the photographic process
    • R. Shaw, "The equivalent quantum efficiency of the photographic process," J. Photogr. Sci 11, 199-204 (1963).
    • (1963) J. Photogr. Sci , vol.11 , pp. 199-204
    • Shaw, R.1
  • 11
    • 0032772594 scopus 로고    scopus 로고
    • A ghost story: Spatio-temporal response characteristics of an indirectdetection flat-panel imager
    • J.H. Siewerdsen and D.A. Jaffray, "A ghost story: Spatio-temporal response characteristics of an indirectdetection flat-panel imager," Med. Phys. 26, No. 8, 1624-1641 (1999).
    • (1999) Med. Phys. , vol.26 , Issue.8 , pp. 1624-1641
    • Siewerdsen, J.H.1    Jaffray, D.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.