메뉴 건너뛰기




Volumn 6510, Issue PART 1, 2007, Pages

A sub-matrix method for extracting x-ray coherent scattering form factors from image plate data

Author keywords

OT; SCAT; SIM

Indexed keywords

COMPUTER AIDED DIAGNOSIS; COMPUTER SIMULATION; MATRIX ALGEBRA; MEAN SQUARE ERROR; X RAY SCATTERING; X RAY SPECTROSCOPY;

EID: 35148830562     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.707962     Document Type: Conference Paper
Times cited : (1)

References (16)
  • 1
    • 0023493560 scopus 로고
    • X-ray diffraction computed tomography
    • G. Harding, J. Kosanetzky and U. Neitzel, "X-ray diffraction computed tomography," Medical Physics 14(4), 515-525 (1987).
    • (1987) Medical Physics , vol.14 , Issue.4 , pp. 515-525
    • Harding, G.1    Kosanetzky, J.2    Neitzel, U.3
  • 2
    • 23744486542 scopus 로고    scopus 로고
    • Analysis of urinary stone components by x-ray coherent scatter: Characterizing composition beyond laboratory x-ray diffractometry
    • M. T. M. Davidson, D. L. Batchelar, S. Velupillai, J. D. Denstedt and I. A. Cunningham, "Analysis of urinary stone components by x-ray coherent scatter: characterizing composition beyond laboratory x-ray diffractometry, " Physics in Medicine and Biology 50(16), 3773-3786 (2005).
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.16 , pp. 3773-3786
    • Davidson, M.T.M.1    Batchelar, D.L.2    Velupillai, S.3    Denstedt, J.D.4    Cunningham, I.A.5
  • 3
    • 33645504253 scopus 로고    scopus 로고
    • Bone-composition imaging using coherent-scatter computed tomography: Assessing bone health beyond bone mineral density
    • D. L. Batchelar, M. T. Davidson, W. Dabrowski and I. A. Cunningham, "Bone-composition imaging using coherent-scatter computed tomography: Assessing bone health beyond bone mineral density," Medical Physics 33(4), 904-915 (2006).
    • (2006) Medical Physics , vol.33 , Issue.4 , pp. 904-915
    • Batchelar, D.L.1    Davidson, M.T.2    Dabrowski, W.3    Cunningham, I.A.4
  • 4
    • 0031802951 scopus 로고    scopus 로고
    • A semianalytic model to investigate the potential applications of x-ray scatter imaging
    • R. J. Leclair and P. C. Johns, "A semianalytic model to investigate the potential applications of x-ray scatter imaging," Medical Physics 25(6), 1008-1020 (1998).
    • (1998) Medical Physics , vol.25 , Issue.6 , pp. 1008-1020
    • Leclair, R.J.1    Johns, P.C.2
  • 5
    • 11044225122 scopus 로고    scopus 로고
    • Measurement of coherent x-ray scatter form factors for amorphous materials using diffractometers
    • P. C. Johns and M. P. Wismayer, "Measurement of coherent x-ray scatter form factors for amorphous materials using diffractometers," Physics in Medicine and Biology 49(23), 5233-5250 (2004).
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.23 , pp. 5233-5250
    • Johns, P.C.1    Wismayer, M.P.2
  • 6
    • 2742546324 scopus 로고    scopus 로고
    • J. H. Hubbell and I. Øverbø, Relativistic atomic form factors and photon coherent scattering cross sections, Journal of Physical and Chemical Reference Data 8(1), 69-105 (1979).
    • J. H. Hubbell and I. Øverbø, "Relativistic atomic form factors and photon coherent scattering cross sections," Journal of Physical and Chemical Reference Data 8(1), 69-105 (1979).
  • 7
    • 0020658505 scopus 로고
    • Coherent scatter in diagnostic radiology
    • P. C. Johns and M. J. Yaffe, "Coherent scatter in diagnostic radiology," Medical Physics 10(1), 40-50 (1983).
    • (1983) Medical Physics , vol.10 , Issue.1 , pp. 40-50
    • Johns, P.C.1    Yaffe, M.J.2
  • 8
    • 0023358685 scopus 로고
    • X-ray diffraction measurements of some plastic materials and body tissues
    • J. Kosanetzky, B. Knoerr, G. Harding and U. Neitzel, "X-ray diffraction measurements of some plastic materials and body tissues," Medical Physics 14(4), 526-532 (1987).
    • (1987) Medical Physics , vol.14 , Issue.4 , pp. 526-532
    • Kosanetzky, J.1    Knoerr, B.2    Harding, G.3    Neitzel, U.4
  • 9
    • 0031470131 scopus 로고    scopus 로고
    • A. Tartari, E. Casnati, C. Bonifazzi and C. Baraldi, Molecular differential cross sections for x-ray coherent scattering in fat and polymethyl methacrylate, Physics in Medicine and Biology 42(12), 2551-2560 (1997).
    • A. Tartari, E. Casnati, C. Bonifazzi and C. Baraldi, "Molecular differential cross sections for x-ray coherent scattering in fat and polymethyl methacrylate," Physics in Medicine and Biology 42(12), 2551-2560 (1997).
  • 11
  • 13
    • 0004236492 scopus 로고    scopus 로고
    • Johns Hopkins University Press, Baltimore, third edition
    • G. H. Golub and C. F. Van Loan, Matrix Computations, Johns Hopkins University Press, Baltimore, third edition (1996).
    • (1996) Matrix Computations
    • Golub, G.H.1    Van Loan, C.F.2
  • 14
    • 0003400321 scopus 로고
    • X-ray diffraction data on liquid water in the temperature range 4°C-200°C
    • 4578, Oak Ridge National Laboratory
    • A. H. Narten, "X-ray diffraction data on liquid water in the temperature range 4°C-200°C," Technical Report ORNL 4578, Oak Ridge National Laboratory (1970).
    • (1970) Technical Report ORNL
    • Narten, A.H.1
  • 16
    • 0004100204 scopus 로고
    • Tables and graphs of photon interaction cross-sections from 1.0-keV to 100-MeV derived from the LLL evaluated nuclear data library
    • Technical Report UCRL-50400, 6, revision 1, Lawrence Livermore Laboratory
    • E. F. Plechaty, D. E. Cullen and R. J. Howerton, "Tables and graphs of photon interaction cross-sections from 1.0-keV to 100-MeV derived from the LLL evaluated nuclear data library," Technical Report UCRL-50400, volume 6, revision 1, Lawrence Livermore Laboratory (1975).
    • (1975)
    • Plechaty, E.F.1    Cullen, D.E.2    Howerton, R.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.