메뉴 건너뛰기




Volumn 25, Issue 6, 1998, Pages 1008-1020

A semianalytic model to investigate the potential applications of x-ray scatter imaging

Author keywords

Coherent scatter; Contrast; Numerical analysis; Signal to noise ratio (SNR); X ray scatter imaging

Indexed keywords

BLOOD; COHERENT SCATTERING; MEDICAL IMAGING; NOISE POLLUTION; NUMERICAL ANALYSIS; PHANTOMS; X RAY RADIOGRAPHY; X RAY SCATTERING; X RAYS;

EID: 0031802951     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598279     Document Type: Article
Times cited : (35)

References (32)
  • 1
    • 0016124445 scopus 로고
    • A further appraisal of the Compton scattering method for determining anatomical cross-sections of the body
    • F. T. Farmer and M. P. Collins, "A further appraisal of the Compton scattering method for determining anatomical cross-sections of the body," Phys. Med. Biol. 19, 808-818 (1974).
    • (1974) Phys. Med. Biol. , vol.19 , pp. 808-818
    • Farmer, F.T.1    Collins, M.P.2
  • 2
    • 0019459793 scopus 로고
    • Compton scatter imaging of transverse sections: An overall appraisal and evaluation for radiotherapy planning
    • J. J. Battista and M. J. Bronskill, "Compton scatter imaging of transverse sections: an overall appraisal and evaluation for radiotherapy planning," Phys. Med. Biol. 26, 81-99 (1981).
    • (1981) Phys. Med. Biol. , vol.26 , pp. 81-99
    • Battista, J.J.1    Bronskill, M.J.2
  • 3
    • 0022492118 scopus 로고
    • Dual-energy Compton scatter tomography
    • G. Harding and R. Tischler, "Dual-energy Compton scatter tomography," Phys. Med. Biol. 31, 477-489 (1986).
    • (1986) Phys. Med. Biol. , vol.31 , pp. 477-489
    • Harding, G.1    Tischler, R.2
  • 6
    • 0021688209 scopus 로고
    • Compton scatter axial tomography with x-rays: SCAT-CAT
    • L. Brateman, A M. Jacobs, and L T. Fitzgerald, "Compton scatter axial tomography with x-rays: SCAT-CAT," Phys. Med. Biol 29, B53-1370 (1984).
    • (1984) Phys. Med. Biol , vol.29
    • Brateman, L.1    Jacobs, A.M.2    Fitzgerald, L.T.3
  • 9
    • 0023339707 scopus 로고
    • Status and outlook of coherent-x-ray scatter imaging
    • G. Harding and J. Kosanetzky, "Status and outlook of coherent-x-ray scatter imaging," J. Opt. Soc. Am. A 4, 933-944 (1987).
    • (1987) J. Opt. Soc. Am. A , vol.4 , pp. 933-944
    • Harding, G.1    Kosanetzky, J.2
  • 10
    • 0023493560 scopus 로고
    • X-ray diffraction computed tomography
    • G. Harding, J. Kosanetzky, and U. Neitzel, "X-ray diffraction computed tomography," Med. Phys. 14, 515-525 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 515-525
    • Harding, G.1    Kosanetzky, J.2    Neitzel, U.3
  • 11
    • 0023358685 scopus 로고
    • X-ray diffraction measurements of some plastic materials and body tissues
    • J Kosanetzky, B. Knoerr, G. Harding, and U. Neitzel, "X-ray diffraction measurements of some plastic materials and body tissues," Med Phys. 14, 526-532 (1987)
    • (1987) Med Phys. , vol.14 , pp. 526-532
    • Kosanetzky, J.1    Knoerr, B.2    Harding, G.3    Neitzel, U.4
  • 12
    • 0030059849 scopus 로고    scopus 로고
    • Angular-dependent coherent scatter measured with a diagnostic x-ray image intensifier-based imaging system
    • M. S. Westmore, A. Fenster, and I. A. Cunningham, "Angular-dependent coherent scatter measured with a diagnostic x-ray image intensifier-based imaging system," Med. Phys. 23, 723-733 (1996)
    • (1996) Med. Phys. , vol.23 , pp. 723-733
    • Westmore, M.S.1    Fenster, A.2    Cunningham, I.A.3
  • 13
    • 0031016811 scopus 로고    scopus 로고
    • Tomographic imaging of the angular-dependent coherent-scatter cross section
    • M. S. Westmore, A. Fenster, and I. A. Cunningham, "Tomographic imaging of the angular-dependent coherent-scatter cross section," Med. Phys. 24, 3-10 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 3-10
    • Westmore, M.S.1    Fenster, A.2    Cunningham, I.A.3
  • 14
    • 0020043450 scopus 로고
    • A coherent/Compton scattering method employing an x-ray tube for measurement of trabecular bone mineral content
    • P. Puumalainen, A. Uimarihuhta, H. Olkkonen, and E. M Alhava, "A coherent/Compton scattering method employing an x-ray tube for measurement of trabecular bone mineral content," Phys. Med. Biol. 27, 425-429 (1982).
    • (1982) Phys. Med. Biol. , vol.27 , pp. 425-429
    • Puumalainen, P.1    Uimarihuhta, A.2    Olkkonen, H.3    Alhava, E.M.4
  • 15
    • 0020629327 scopus 로고
    • Characterization of tissue via coherent-to-Compton scattering ratio: Sensitivity considerations
    • A. Karellas, I. Leichter, J. D. Craven, and M. A. Greenfteld, "Characterization of tissue via coherent-to-Compton scattering ratio: Sensitivity considerations," Med. Phys. 10, 605-609 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 605-609
    • Karellas, A.1    Leichter, I.2    Craven, J.D.3    Greenfteld, M.A.4
  • 16
    • 0021015949 scopus 로고
    • Assessment of gamma ray scattering for the characterisation of biological material
    • R. S Holt, K. Kouris, M. J. Cooper, and D. F. Jackson, "Assessment of gamma ray scattering for the characterisation of biological material," Phys Med. Biol. 28, 1435-1440 (1983).
    • (1983) Phys Med. Biol. , vol.28 , pp. 1435-1440
    • Holt, R.S.1    Kouris, K.2    Cooper, M.J.3    Jackson, D.F.4
  • 17
    • 0022045633 scopus 로고
    • Elastic and Compton scattering with W Kα x-radiation
    • M. Cooper, R. S. Holt, and G. Harding, "Elastic and Compton scattering with W Kα x-radiation," J. Phys. E 18, 354-357 (1985).
    • (1985) J. Phys. E , vol.18 , pp. 354-357
    • Cooper, M.1    Holt, R.S.2    Harding, G.3
  • 18
    • 0017841479 scopus 로고
    • Image information content and patient exposure
    • J. W. Motz and M. Danos, "Image information content and patient exposure," Med. Phys 5, 8-22 (1978).
    • (1978) Med. Phys , vol.5 , pp. 8-22
    • Motz, J.W.1    Danos, M.2
  • 19
    • 0020537251 scopus 로고
    • Calculation of x-ray single scattering in diagnostic radiology
    • L. R. M. Morin and A. Berroir, "Calculation of x-ray single scattering in diagnostic radiology," Phys. Med Biol. 28, 789-797 (1983).
    • (1983) Phys. Med Biol. , vol.28 , pp. 789-797
    • Morin, L.R.M.1    Berroir, A.2
  • 20
    • 0020658505 scopus 로고
    • Coherent scatter in diagnostic radiology
    • P. C. Johns and M. J. Yaffe, "Coherent scatter in diagnostic radiology," Med Phys. 10, 40-50 (1983)
    • (1983) Med Phys. , vol.10 , pp. 40-50
    • Johns, P.C.1    Yaffe, M.J.2
  • 21
    • 0021058196 scopus 로고
    • On the significance of very small angle scattered radiation to radiographic imaging at low energies
    • E. P. Muntz, T. Fewell, R. Jennings, and H. Bernstein, "On the significance of very small angle scattered radiation to radiographic imaging at low energies," Med. Phys 10, 819-823 (1983).
    • (1983) Med. Phys , vol.10 , pp. 819-823
    • Muntz, E.P.1    Fewell, T.2    Jennings, R.3    Bernstein, H.4
  • 25
    • 2742546324 scopus 로고
    • Relativistic atomic form factors and photon coherent scattering cross sections
    • J. H. Hubbell and I. Øverbø, "Relativistic atomic form factors and photon coherent scattering cross sections," J. Phys. Chem. Ref. Data 8, 69-105 (1979).
    • (1979) J. Phys. Chem. Ref. Data , vol.8 , pp. 69-105
    • Hubbell, J.H.1    Øverbø, I.2
  • 26
    • 0003444170 scopus 로고
    • Report No. 23, Table 108, (item #2 - adipose tissue, item #77 - skeletal muscle) Pergamon, Oxford
    • International Commission on Radiological Protection (ICRP), Report No. 23, "Report of the task group on reference man," Table 108, pp. 290-324 (item #2 - adipose tissue, item #77 - skeletal muscle) (Pergamon, Oxford, 1975).
    • (1975) Report of the Task Group on Reference Man , pp. 290-324
  • 27
    • 0020076149 scopus 로고
    • Phantom materials for radiation dosimetry. I. Liquids and gels
    • C. Constantinou, "Phantom materials for radiation dosimetry. I. Liquids and gels," Br. J. Radiol 55, 217-224 (1982).
    • (1982) Br. J. Radiol , vol.55 , pp. 217-224
    • Constantinou, C.1
  • 28
    • 0018125662 scopus 로고
    • Tissue substitutes in experimental radiation physics
    • D. R. White, "Tissue substitutes in experimental radiation physics," Med. Phys. 5, 467-479 (1978).
    • (1978) Med. Phys. , vol.5 , pp. 467-479
    • White, D.R.1
  • 29
    • 84913289526 scopus 로고
    • Atomic form factors, incoherent scattering functions, and photon scattering cross sections
    • Erratum 6, 615-616 (1977)
    • J. H. Hubbell, Wm. J. Veigele, E. A. Briggs, R T. Brown, D. T. Cromer, and R. J. Howerton, "Atomic form factors, incoherent scattering functions, and photon scattering cross sections," J. Phys. Chem. Ref. Data 4, 471-538 (1975); Erratum 6, 615-616 (1977).
    • (1975) J. Phys. Chem. Ref. Data , vol.4 , pp. 471-538
    • Hubbell, J.H.1    Veigele, Wm.J.2    Briggs, E.A.3    Brown, R.T.4    Cromer, D.T.5    Howerton, R.J.6
  • 31
    • 0022387331 scopus 로고
    • Coherent scatter in radiographic imaging: A Monte Carlo simulation study
    • U. Neitzel, J. Kosanetzky, and G. Harding, "Coherent scatter in radiographic imaging: a Monte Carlo simulation study," Phys. Med. Biol. 30, 1289-1296 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 1289-1296
    • Neitzel, U.1    Kosanetzky, J.2    Harding, G.3
  • 32
    • 0020899887 scopus 로고
    • Scattered radiation in diagnostic radiology: Magnitudes, effects, and methods of reduction
    • M. J. Yaffe and P. C. Johns, "Scattered radiation in diagnostic radiology: Magnitudes, effects, and methods of reduction," J. Appl Photogr Eng. 9, 184-195 (1983).
    • (1983) J. Appl Photogr Eng. , vol.9 , pp. 184-195
    • Yaffe, M.J.1    Johns, P.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.