메뉴 건너뛰기




Volumn 6510, Issue PART 1, 2007, Pages

Progress in electron-multiplying CCD (EMCCD) based, high-resolution, high-sensitivity x-ray detector for fluoroscopy and radiography

Author keywords

DCT; DX; METR; SIM; SYS

Indexed keywords

FIBER OPTIC TAPER (FOT); FIELD-OF-VIEW (FOV); INSTRUMENTATION NOISE EQUIVALENT EXPOSURE (INEE);

EID: 35048867888     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.713140     Document Type: Conference Paper
Times cited : (14)

References (31)
  • 3
    • 0344393789 scopus 로고    scopus 로고
    • Micro- angiography for neuro-vascular imaging. II Cascade model analysis
    • A. Ganguly, S. Rudin, D.R. Bednarek, K.R. Hoffmann, "Micro- angiography for neuro-vascular imaging. II Cascade model analysis," Med. Phys. 30(11), pp. 3029-3039, 2003
    • (2003) Med. Phys , vol.30 , Issue.11 , pp. 3029-3039
    • Ganguly, A.1    Rudin, S.2    Bednarek, D.R.3    Hoffmann, K.R.4
  • 4
    • 0032403613 scopus 로고    scopus 로고
    • Linear-systems modeling of parallel cascaded stochastic processes: The NPS of radiographic screens with reabsorption of characteristic x-rays
    • I.A. Cunningham, "Linear-systems modeling of parallel cascaded stochastic processes: The NPS of radiographic screens with reabsorption of characteristic x-rays," Proc. SPIE Vol. 3336, pp. 220-230, 1998
    • (1998) Proc. SPIE , vol.3336 , pp. 220-230
    • Cunningham, I.A.1
  • 5
    • 0034767933 scopus 로고    scopus 로고
    • Parallel cascade: New ways to describe noise transfer in medical imaging systems
    • J. Yao and I.A. Cunningham, "Parallel cascade: New ways to describe noise transfer in medical imaging systems," Med. Phys. Vol. 28, pp. 2020-2038, 2001
    • (2001) Med. Phys , vol.28 , pp. 2020-2038
    • Yao, J.1    Cunningham, I.A.2
  • 6
    • 0023339134 scopus 로고
    • Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms
    • M. Rabbani, R. Shaw, R. Van Metter, "Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms," J. Opt. Soc. Am. A, Vol. 4, No. 5, pp. 895-901, 1987
    • (1987) J. Opt. Soc. Am. A , vol.4 , Issue.5 , pp. 895-901
    • Rabbani, M.1    Shaw, R.2    Van Metter, R.3
  • 7
    • 0032739275 scopus 로고    scopus 로고
    • Analysis of the detective quantum efficiency of a developmental detector fo digital mammography
    • M. B. Williams, P.U. Simoni, L. Smilowitz, M. Stanton, W. Philips, A. Stewart, "Analysis of the detective quantum efficiency of a developmental detector fo digital mammography," Med. Phys. 26 (11), pp. 2273-2285, 1999
    • (1999) Med. Phys , vol.26 , Issue.11 , pp. 2273-2285
    • Williams, M.B.1    Simoni, P.U.2    Smilowitz, L.3    Stanton, M.4    Philips, W.5    Stewart, A.6
  • 8
    • 0029458544 scopus 로고
    • Effect of Finite Detector-Element Width on the Spatial-Frequency-Dependent Detective Quantum Efficiency
    • 24322
    • I.A. Cunningham, M.S. Westmore, A. Fenster, "Effect of Finite Detector-Element Width on the Spatial-Frequency-Dependent Detective Quantum Efficiency," SPIE Vol. 24322, pp. 143-151, 1995
    • (1995) SPIE , pp. 143-151
    • Cunningham, I.A.1    Westmore, M.S.2    Fenster, A.3
  • 9
    • 0037321857 scopus 로고    scopus 로고
    • Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector
    • W. Zhao, W.G. Ji, A. Debrie, J.A. Rowlands, "Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector," Med. Phys, 30 (2), pp. 254-263, 2003
    • (2003) Med. Phys , vol.30 , Issue.2 , pp. 254-263
    • Zhao, W.1    Ji, W.G.2    Debrie, A.3    Rowlands, J.A.4
  • 11
    • 0028941060 scopus 로고
    • X-ray imaging using amorphous selenium: Inherent spatial resolution
    • W. Que and J.A. Rowlands, "X-ray imaging using amorphous selenium: Inherent spatial resolution," Med. Phys. Vol. 22 (4), pp. 365-374, 1995
    • (1995) Med. Phys , vol.22 , Issue.4 , pp. 365-374
    • Que, W.1    Rowlands, J.A.2
  • 12
    • 0000729933 scopus 로고    scopus 로고
    • X-ray Production, Interaction, and Detection in Diagnostic Imaging
    • edited by J. Beutel, H.L. Kundel, and R.L. Van Metter SPIE, Bellingham, WA
    • J.M. Boone, "X-ray Production, Interaction, and Detection in Diagnostic Imaging," Handbook of Medical Imaging Physics and Psychophysics, edited by J. Beutel, H.L. Kundel, and R.L. Van Metter (SPIE, Bellingham, WA, 2000), pp. 1-81
    • (2000) Handbook of Medical Imaging Physics and Psychophysics , pp. 1-81
    • Boone, J.M.1
  • 13
    • 0003523753 scopus 로고    scopus 로고
    • Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients
    • NIST Physical Reference Data
    • "Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients," NIST Physical Reference Data, 1996
    • (1996)
  • 14
    • 4644293266 scopus 로고    scopus 로고
    • X-ray imaging performance of structured cesium iodide scintillators
    • W. Zhao, G. Ristic, J.A. Rowlands, "X-ray imaging performance of structured cesium iodide scintillators," Med. Phys. Vol. 31 (9), pp. 2594-2605, 2004
    • (2004) Med. Phys , vol.31 , Issue.9 , pp. 2594-2605
    • Zhao, W.1    Ristic, G.2    Rowlands, J.A.3
  • 15
    • 0034768121 scopus 로고    scopus 로고
    • Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors
    • W. Zhao, W.G. Ji, J.A. Rowlands, "Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors," Med. Phys. 28(10), 2039-2049, 2001
    • (2001) Med. Phys , vol.28 , Issue.10 , pp. 2039-2049
    • Zhao, W.1    Ji, W.G.2    Rowlands, J.A.3
  • 16
    • 0037321857 scopus 로고    scopus 로고
    • Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector
    • W. Zhao, W.G. Ji, A. Debrie, J.A. Rowlands, "Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector," Med. Phys. 30(2), 254-263, 2003
    • (2003) Med. Phys , vol.30 , Issue.2 , pp. 254-263
    • Zhao, W.1    Ji, W.G.2    Debrie, A.3    Rowlands, J.A.4
  • 17
    • 0020575045 scopus 로고
    • Energy and angular dependence of x-ray absorption and its effect on radiographic response in screen-film systems
    • H. Chan, K. Doi, "Energy and angular dependence of x-ray absorption and its effect on radiographic response in screen-film systems," Phys. Med. Biold., Vol. 28 (5), 565-579, 1983
    • (1983) Phys. Med. Biold , vol.28 , Issue.5 , pp. 565-579
    • Chan, H.1    Doi, K.2
  • 18
    • 23244467460 scopus 로고    scopus 로고
    • Microangiographic Image Guided Localization of a New Asymmetric Stent for Treatment of Cerebral Aneurysms
    • C.N. lonita, S. Rudin, K.R. Hoffmann, D.R. Bednarek, " Microangiographic Image Guided Localization of a New Asymmetric Stent for Treatment of Cerebral Aneurysms," Proc. of SPIE Vol. 5744, pp. 354-365
    • Proc. of SPIE , vol.5744 , pp. 354-365
    • lonita, C.N.1    Rudin, S.2    Hoffmann, K.R.3    Bednarek, D.R.4
  • 19
    • 35048874077 scopus 로고    scopus 로고
    • Technical Information, Cat. No. TMCP9003E01, Feb. 1996, Hamamatsu Corp., Bridgewater, NJ
    • Technical Information, Cat. No. TMCP9003E01, Feb. 1996, Hamamatsu Corp., Bridgewater, NJ
  • 21
    • 35048849320 scopus 로고    scopus 로고
    • Instrumentation Noise Equivalent Exposure (INEE) Representation for High Sensitivity X-ray Imaging Detectors
    • Med. Phys, 6, TU-FF-A4-01, June
    • G. Yadava, S. Rudin, A.T. Kuhls, V. Patel, D.R. Bednarek, K.R. Hoffmann, "Instrumentation Noise Equivalent Exposure (INEE) Representation for High Sensitivity X-ray Imaging Detectors," Med. Phys., Vol. 33 (6), TU-FF-A4-01, June 2006
    • (2006) , vol.33
    • Yadava, G.1    Rudin, S.2    Kuhls, A.T.3    Patel, V.4    Bednarek, D.R.5    Hoffmann, K.R.6
  • 22
    • 0035471198 scopus 로고    scopus 로고
    • Impactron - A New Solid State Image Intensifier
    • J. Hynecek, "Impactron - A New Solid State Image Intensifier," IEEE Transactions on Electron Devices, Vol. 48(10), pp. 2238-2241, 2001
    • (2001) IEEE Transactions on Electron Devices , vol.48 , Issue.10 , pp. 2238-2241
    • Hynecek, J.1
  • 23
    • 0043175225 scopus 로고    scopus 로고
    • The noise performance of electron multiplying Charge-Coupled Devices
    • M.S. Robbins and B.J. Hadwen, "The noise performance of electron multiplying Charge-Coupled Devices," IEE Transactions on Electron Devices, Vol. 50 (5), pp. 1227-1232, 2003
    • (2003) IEE Transactions on Electron Devices , vol.50 , Issue.5 , pp. 1227-1232
    • Robbins, M.S.1    Hadwen, B.J.2
  • 24
  • 25
    • 0037951802 scopus 로고    scopus 로고
    • Electron-multiplying CCD: The new ICCD
    • D.J. Denvir and E. Conroy, "Electron-multiplying CCD: the new ICCD," Proc. SPIE, vol. 4796, pp. 164-174, 2003
    • (2003) Proc. SPIE , vol.4796 , pp. 164-174
    • Denvir, D.J.1    Conroy, E.2
  • 27
    • 20044380936 scopus 로고    scopus 로고
    • Photon-counting versus an integrating CCD-based gamma camera: Important consequences for spatial resolution
    • F.J. Beekman, G.A. de Vree, "Photon-counting versus an integrating CCD-based gamma camera: important consequences for spatial resolution," Phys. Med. Biol. Vol. 50, N109-119, 2005
    • (2005) Phys. Med. Biol , vol.50
    • Beekman, F.J.1    de Vree, G.A.2
  • 29
    • 33745348262 scopus 로고    scopus 로고
    • Single-photon spatial and energy resolution enhancement of a columnar CsI(Tl) / EMCCD gamma-camera using maximum-likelihood estimation
    • Physics of Medical Imaging
    • B. W. Miller, H. B. Barber, H. H. Barrett, I. Shestakova, B. Singh, V.V. Nagarkar, "Single-photon spatial and energy resolution enhancement of a columnar CsI(Tl) / EMCCD gamma-camera using maximum-likelihood estimation," Proc. of SPIE Physics of Medical Imaging, Vol. 6142, 61421T-1, 2006
    • (2006) Proc. of SPIE , vol.6142
    • Miller, B.W.1    Barber, H.B.2    Barrett, H.H.3    Shestakova, I.4    Singh, B.5    Nagarkar, V.V.6
  • 30
    • 0002050483 scopus 로고    scopus 로고
    • Applied Linear-Systems Theory
    • edited by J. Beutel, H.L. Kundel, and R.L. Van Metter SPIE, Bellingham, WA
    • I.A. Cunningham, "Applied Linear-Systems Theory," Handbook of Medical Imaging Physics and Psychophysics, edited by J. Beutel, H.L. Kundel, and R.L. Van Metter (SPIE, Bellingham, WA, 2000), pp. 82-160
    • (2000) Handbook of Medical Imaging Physics and Psychophysics , pp. 82-160
    • Cunningham, I.A.1
  • 31
    • 35048858683 scopus 로고    scopus 로고
    • 78, Spectrum processor. York: The Institute of Physics and Engineering in Medicine
    • Reilly AJ, Sutton D. IPEM Report 78 - Spectrum processor. York: The Institute of Physics and Engineering in Medicine, 1997.
    • (1997) IPEM Report
    • Reilly, A.J.1    Sutton, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.