메뉴 건너뛰기




Volumn 18, Issue 7, 2007, Pages 559-564

Implantation of sirolimus-eluting stents in saphenous vein grafts is associated with high clinical follow-up event rates compared with treatment of native vessels

Author keywords

Drugs; Saphenous vein grafts; Stent

Indexed keywords

ACETYLSALICYLIC ACID; ANTICOAGULANT AGENT; CLOPIDOGREL; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; FIBRINOGEN RECEPTOR ANTAGONIST; HYDROXYMETHYLGLUTARYL COENZYME A REDUCTASE INHIBITOR; RAPAMYCIN; RECEPTOR BLOCKING AGENT; TICLOPIDINE;

EID: 35048865818     PISSN: 09546928     EISSN: None     Source Type: Journal    
DOI: 10.1097/MCA.0b013e3282ef5b40     Document Type: Article
Times cited : (25)

References (20)
  • 2
    • 0030245599 scopus 로고    scopus 로고
    • Coronary bypass graft fate and patients outcome: Angiographic follow-up of 5065 grafts related to survival and reoperation in 1388 patients during 25 years
    • Fitzgibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR. Coronary bypass graft fate and patients outcome: angiographic follow-up of 5065 grafts related to survival and reoperation in 1388 patients during 25 years. J Am Coll Cardiol 1996;28:616-626.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 616-626
    • Fitzgibbon, G.M.1    Kafka, H.P.2    Leach, A.J.3    Keon, W.J.4    Hooper, G.D.5    Burton, J.R.6
  • 4
    • 0029089448 scopus 로고
    • Immediate results and late out-comes after stent implantation in saphenous vein graft lesions: The multi-center U.S. Palmaz-Schatz stent experience
    • Wong SC, Baim DS, Schatz RA, Teirstein PS, King SB 3rd, Curry RC Jr, et al. Immediate results and late out-comes after stent implantation in saphenous vein graft lesions: the multi-center U.S. Palmaz-Schatz stent experience. J Am Coll Cardiol 1995;26:704-712.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 704-712
    • Wong, S.C.1    Baim, D.S.2    Schatz, R.A.3    Teirstein, P.S.4    King 3rd, S.B.5    Curry Jr, R.C.6
  • 5
    • 0037030658 scopus 로고    scopus 로고
    • RAVEL Study Group. A randomized comparison of sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, et al., RAVEL Study Group. A randomized comparison of sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1173-1180.
    • (2002) N Engl J Med , vol.346 , pp. 1173-1180
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3    Fajadet, J.4    Ban Hayashi, E.5    Perin, M.6
  • 6
    • 0141765805 scopus 로고    scopus 로고
    • SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al., SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-1323.
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3    Fitzgerald, P.J.4    Holmes, D.R.5    O'Shaughnessy, C.6
  • 7
    • 9144249927 scopus 로고    scopus 로고
    • TAXUS-IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease
    • Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, et al., TAXUS-IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221- 231.
    • (2004) N Engl J Med , vol.350 , pp. 221-231
    • Stone, G.W.1    Ellis, S.G.2    Cox, D.A.3    Hermiller, J.4    O'Shaughnessy, C.5    Mann, J.T.6
  • 11
    • 23044442806 scopus 로고    scopus 로고
    • Immediate and one-year outcome of percutaneous intervention of saphenous vein graft disease with paclitaxel-eluting stents
    • Tsuchida K, Ong ATL, Aoki J, van Mieghem CAG, Rodriguez-Granillo GA, Valgimigli M, et al. Immediate and one-year outcome of percutaneous intervention of saphenous vein graft disease with paclitaxel-eluting stents. Am J Cardiol 2005;96:395-398.
    • (2005) Am J Cardiol , vol.96 , pp. 395-398
    • Tsuchida, K.1    Ong, A.T.L.2    Aoki, J.3    van Mieghem, C.A.G.4    Rodriguez-Granillo, G.A.5    Valgimigli, M.6
  • 12
    • 29244439559 scopus 로고    scopus 로고
    • Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention
    • Chu WW, Rha SW, Kuchulakanti PK, Cheneau E, Torguson R, Pinnow E, et al. Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention. Am J Cardiol 2006;97:34-37.
    • (2006) Am J Cardiol , vol.97 , pp. 34-37
    • Chu, W.W.1    Rha, S.W.2    Kuchulakanti, P.K.3    Cheneau, E.4    Torguson, R.5    Pinnow, E.6
  • 13
    • 21144454374 scopus 로고    scopus 로고
    • German Cypher Stent Registry. Incidence and predictors of target vessel revascularization and clinical event rates of the sirolimus-eluting coronary stent (results from the prospective multicenter German Cypher Stent Registry)
    • Zahn R, Hamm CW, Schneider S, Zeymer U, Nienaber CA, Richardt G, et al.; German Cypher Stent Registry. Incidence and predictors of target vessel revascularization and clinical event rates of the sirolimus-eluting coronary stent (results from the prospective multicenter German Cypher Stent Registry). Am J Cardiol 2005;95:1302-1308.
    • (2005) Am J Cardiol , vol.95 , pp. 1302-1308
    • Zahn, R.1    Hamm, C.W.2    Schneider, S.3    Zeymer, U.4    Nienaber, C.A.5    Richardt, G.6
  • 14
    • 1942422799 scopus 로고    scopus 로고
    • Zahn R, Hamm CW, Zeymer U, Schneider S, Nienaber CA, Richardt G, et al., for the German Cypher Registry. 'Real life' use of sirolimus-eluting stents in Germany. Results from the prospective multi-centre German Cypher Registry. Z Kardiol 2004;93:287-294.
    • Zahn R, Hamm CW, Zeymer U, Schneider S, Nienaber CA, Richardt G, et al., for the German Cypher Registry. 'Real life' use of sirolimus-eluting stents in Germany. Results from the prospective multi-centre German Cypher Registry. Z Kardiol 2004;93:287-294.
  • 15
    • 33845297692 scopus 로고    scopus 로고
    • Zahn R, Hamm CW, Schneider S, Zeymer U, Richardt R, Kelm M, et al., for the German Cypher Stent Registry. Predictors of death or myocardial infarction during follow-up after coronary stenting with the sirolimus-eluting stent. Results from the prospective multi-center German Cypher Stent Registry. Am Heart J 2006;152:1146-1152.
    • Zahn R, Hamm CW, Schneider S, Zeymer U, Richardt R, Kelm M, et al., for the German Cypher Stent Registry. Predictors of death or myocardial infarction during follow-up after coronary stenting with the sirolimus-eluting stent. Results from the prospective multi-center German Cypher Stent Registry. Am Heart J 2006;152:1146-1152.
  • 17
    • 29244439559 scopus 로고    scopus 로고
    • Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention
    • Chu WW, Rha SW, Kuchulakanti PK, Cheneau E, Torguson R, Pinnow E, et al. Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention. Am J Cardiol 2006;97:34-37.
    • (2006) Am J Cardiol , vol.97 , pp. 34-37
    • Chu, W.W.1    Rha, S.W.2    Kuchulakanti, P.K.3    Cheneau, E.4    Torguson, R.5    Pinnow, E.6
  • 18
    • 20144389837 scopus 로고    scopus 로고
    • Treatment of saphenous vein graft lesions with drug-eluting stents: Immediate and midterm outcome
    • Ge L, Iakovou I, Sangiorgi GM, Chieffo A, Melzi G, Cosgrave J, et al. Treatment of saphenous vein graft lesions with drug-eluting stents: immediate and midterm outcome. J Am Coll Cardiol 2005;45:989-994.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 989-994
    • Ge, L.1    Iakovou, I.2    Sangiorgi, G.M.3    Chieffo, A.4    Melzi, G.5    Cosgrave, J.6
  • 19
    • 34147197569 scopus 로고    scopus 로고
    • Implantation of paclitaxel-eluting stents in saphenous vein grafts. Clinical and angiographic follow-up results from a multicenter study
    • Hoffmann R, Pohl T, Köster R, Blindt R, Boeckstegers P, Heitzer T. Implantation of paclitaxel-eluting stents in saphenous vein grafts. Clinical and angiographic follow-up results from a multicenter study. Heart 2007;93:331-334.
    • (2007) Heart , vol.93 , pp. 331-334
    • Hoffmann, R.1    Pohl, T.2    Köster, R.3    Blindt, R.4    Boeckstegers, P.5    Heitzer, T.6
  • 20
    • 33845410666 scopus 로고    scopus 로고
    • Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in diseased saphenous vein grafts
    • Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, Bruining N, et al. Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in diseased saphenous vein grafts. J Am Coll Cardiol 2006;48:2423-2431.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2423-2431
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    Van den Heuvel, P.4    Convens, C.5    Bruining, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.