-
1
-
-
2442681474
-
Cardiac diseases in maintenance hemodialysis patients: Results of the HEMO Study
-
Cheung AK, Sarnak MJ, Yan G, et al: Cardiac diseases in maintenance hemodialysis patients: results of the HEMO Study. Kidney Int 65: 2380-2389, 2004.
-
(2004)
Kidney Int
, vol.65
, pp. 2380-2389
-
-
Cheung, A.K.1
Sarnak, M.J.2
Yan, G.3
-
2
-
-
33746546684
-
The epidemics of cardiovascular disease in elderly patients with chronic kidney disease: Two facets of the same problem
-
Covic A, Gusbeth-Tatomir P, Goldsmith DJ: The epidemics of cardiovascular disease in elderly patients with chronic kidney disease: two facets of the same problem. Int Urol Nephrol 38: 371-379, 2006.
-
(2006)
Int Urol Nephrol
, vol.38
, pp. 371-379
-
-
Covic, A.1
Gusbeth-Tatomir, P.2
Goldsmith, D.J.3
-
3
-
-
33845933701
-
-
Golebiowski T, Weyde W, Krajewska M, et al: Coronary heart disease in patients with end-stage renal disease on maintenance dialysis, II: prophylaxis and treatment. Postepy Hig Med Dosw (Online) 60: 290-294, 2006.
-
Golebiowski T, Weyde W, Krajewska M, et al: Coronary heart disease in patients with end-stage renal disease on maintenance dialysis, II: prophylaxis and treatment. Postepy Hig Med Dosw (Online) 60: 290-294, 2006.
-
-
-
-
4
-
-
0025616201
-
Measurement of cardiac output: Fick principle using catheterization
-
Fagard R, Conway J: Measurement of cardiac output: Fick principle using catheterization. Eur Heart J 11: 1-5, 1990.
-
(1990)
Eur Heart J
, vol.11
, pp. 1-5
-
-
Fagard, R.1
Conway, J.2
-
5
-
-
0030250242
-
Validation of a novel ultrasound dilution method to measure cardiac output during hemodialysis
-
Kisloukhine VV, Dean DA: Validation of a novel ultrasound dilution method to measure cardiac output during hemodialysis. ASAIO J 42: M906-M907, 1996.
-
(1996)
ASAIO J
, vol.42
-
-
Kisloukhine, V.V.1
Dean, D.A.2
-
6
-
-
0032812832
-
Cardiac output and central blood volume during hemodialysis: Methodology
-
Krivitski NM, Depner TA: Cardiac output and central blood volume during hemodialysis: methodology. Adv Ren Replace Ther 6: 225-232, 1999.
-
(1999)
Adv Ren Replace Ther
, vol.6
, pp. 225-232
-
-
Krivitski, N.M.1
Depner, T.A.2
-
7
-
-
0030250734
-
Validation of a new method to measure cardiac output during extracorporeal detoxification
-
Nikiforov YV, Kisluchine VV, Chaus NI: Validation of a new method to measure cardiac output during extracorporeal detoxification. ASAIO J 42: M903-M905, 1996.
-
(1996)
ASAIO J
, vol.42
-
-
Nikiforov, Y.V.1
Kisluchine, V.V.2
Chaus, N.I.3
-
8
-
-
0017229538
-
Measurement of cardiac output by electrical impedance at rest and during exercise
-
Denniston JC, Maher JT, Reeves JT, Cruz JC, Cymerman A, Grover RF: Measurement of cardiac output by electrical impedance at rest and during exercise. J Appl Physiol 40: 91-95, 1976.
-
(1976)
J Appl Physiol
, vol.40
, pp. 91-95
-
-
Denniston, J.C.1
Maher, J.T.2
Reeves, J.T.3
Cruz, J.C.4
Cymerman, A.5
Grover, R.F.6
-
9
-
-
33746554946
-
Impedance cardiography derived cardiac output in hemodialysis patients: A study of reproducibility and comparison with echocardiography
-
Karakitsos DN, Patrianakos AP, Paraskevopoulos A, et al: Impedance cardiography derived cardiac output in hemodialysis patients: a study of reproducibility and comparison with echocardiography. Int J Artif Organs 29: 564-572, 2006.
-
(2006)
Int J Artif Organs
, vol.29
, pp. 564-572
-
-
Karakitsos, D.N.1
Patrianakos, A.P.2
Paraskevopoulos, A.3
-
10
-
-
0037940270
-
Bench to bedside: Electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography
-
Summers RL, Shoemaker WC, Peacock WF, Ander DS, Coleman TG: Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography. Acad Emerg Med 10: 669-680, 2003.
-
(2003)
Acad Emerg Med
, vol.10
, pp. 669-680
-
-
Summers, R.L.1
Shoemaker, W.C.2
Peacock, W.F.3
Ander, D.S.4
Coleman, T.G.5
-
11
-
-
0344765505
-
A software package for noninvasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function
-
Gratze G, Fortin J, Holler A, et al: A software package for noninvasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function. Comput Biol Med 28: 121-142, 1998.
-
(1998)
Comput Biol Med
, vol.28
, pp. 121-142
-
-
Gratze, G.1
Fortin, J.2
Holler, A.3
-
12
-
-
25444523480
-
Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy
-
Braun MU, Schnabel A, Rauwolf T, Schulze M, Strasser RH: Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy. J Interv Card Electrophysiol 13: 223-229, 2005.
-
(2005)
J Interv Card Electrophysiol
, vol.13
, pp. 223-229
-
-
Braun, M.U.1
Schnabel, A.2
Rauwolf, T.3
Schulze, M.4
Strasser, R.H.5
-
13
-
-
33746367766
-
Continuous noninvasive blood pressure monitoring using concentrically interlocking control loops
-
Fortin J, Marte W, Grullenberger R, et al: Continuous noninvasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med 36: 941-957, 2006.
-
(2006)
Comput Biol Med
, vol.36
, pp. 941-957
-
-
Fortin, J.1
Marte, W.2
Grullenberger, R.3
-
14
-
-
14744288637
-
Prognostic value of hemodynamic findings from impedance cardiography in hypertensive stroke
-
Ramirez MF, Tibayan RT, Marinas CE, Yamamoto ME, Caguioa EV: Prognostic value of hemodynamic findings from impedance cardiography in hypertensive stroke. Am J Hypertens 18: 65S-72S, 2005.
-
(2005)
Am J Hypertens
, vol.18
-
-
Ramirez, M.F.1
Tibayan, R.T.2
Marinas, C.E.3
Yamamoto, M.E.4
Caguioa, E.V.5
-
15
-
-
33747840723
-
Noninvasive beat-tobeat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement
-
Fortin J, Habenbacher W, Heller A, et al: Noninvasive beat-tobeat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement. Comput Biol Med 36: 1185-1203, 2006.
-
(2006)
Comput Biol Med
, vol.36
, pp. 1185-1203
-
-
Fortin, J.1
Habenbacher, W.2
Heller, A.3
-
16
-
-
0033253948
-
Bioelectric impedance in the estimation of hemodynamic and fluid status in dialysis patients
-
Ristovska V, Masin G, Ivanovski N, et al: Bioelectric impedance in the estimation of hemodynamic and fluid status in dialysis patients. Acta Med Croatica 53: 67-71, 1999.
-
(1999)
Acta Med Croatica
, vol.53
, pp. 67-71
-
-
Ristovska, V.1
Masin, G.2
Ivanovski, N.3
-
17
-
-
33646243223
-
Impedance cardiography: A potential monitor for hemodialysis
-
Wynne JL, Ovadje LO, Akridge CM, Sheppard SW, Vogel RL, Van de Water JM: Impedance cardiography: a potential monitor for hemodialysis. J Surg Res 133: 55-60, 2006.
-
(2006)
J Surg Res
, vol.133
, pp. 55-60
-
-
Wynne, J.L.1
Ovadje, L.O.2
Akridge, C.M.3
Sheppard, S.W.4
Vogel, R.L.5
Van de Water, J.M.6
-
18
-
-
33645507975
-
Longer treatment time and slower ultrafiltration in hemodialysis: Associations with reduced mortality in the DOPPS
-
Saran R, Bragg-Gresham JL, Levin NW, et al: Longer treatment time and slower ultrafiltration in hemodialysis: associations with reduced mortality in the DOPPS. Kidney Int 69: 1222-1228, 2006.
-
(2006)
Kidney Int
, vol.69
, pp. 1222-1228
-
-
Saran, R.1
Bragg-Gresham, J.L.2
Levin, N.W.3
-
19
-
-
0036659406
-
Chronic hypotension in the dialysis patient
-
Cases A, Coll E: Chronic hypotension in the dialysis patient. J Nephrol 15: 331-335, 2002.
-
(2002)
J Nephrol
, vol.15
, pp. 331-335
-
-
Cases, A.1
Coll, E.2
-
20
-
-
0035743177
-
The role of autonomic neuropathy in the genesis of intradialytic hypotension
-
Chang MH, Chou KJ: The role of autonomic neuropathy in the genesis of intradialytic hypotension. Am J Nephrol 21: 357-361, 2001.
-
(2001)
Am J Nephrol
, vol.21
, pp. 357-361
-
-
Chang, M.H.1
Chou, K.J.2
-
21
-
-
17444412295
-
Hypotension during hemodialysis results from an impairment of arteriolar tone and left ventricular function
-
Nette RW, van den Dorpel MA, Krepel HP, et al: Hypotension during hemodialysis results from an impairment of arteriolar tone and left ventricular function. Clin Nephrol 63: 276-283, 2005.
-
(2005)
Clin Nephrol
, vol.63
, pp. 276-283
-
-
Nette, R.W.1
van den Dorpel, M.A.2
Krepel, H.P.3
-
22
-
-
0032427658
-
Systemic vascular resistance in intradialytic hypotension determined by means of impedance cardiography
-
Straver B, Roggekamp MC, de Vries PM, ter Wee PM: Systemic vascular resistance in intradialytic hypotension determined by means of impedance cardiography. Blood Purif 16: 281-289, 1998.
-
(1998)
Blood Purif
, vol.16
, pp. 281-289
-
-
Straver, B.1
Roggekamp, M.C.2
de Vries, P.M.3
ter Wee, P.M.4
-
23
-
-
0019822796
-
Noninvasive monitoring of cardiac function during haemodialysis
-
Thayssen P, Andersen KH, Pindborg T: Noninvasive monitoring of cardiac function during haemodialysis. Scand J Urol Nephrol 15: 313-317, 1981.
-
(1981)
Scand J Urol Nephrol
, vol.15
, pp. 313-317
-
-
Thayssen, P.1
Andersen, K.H.2
Pindborg, T.3
-
24
-
-
0031768672
-
The hemodynamic effect of different ultrafiltration rates in patients with cardiac failure and patients without cardiac failure: Comparison between isolated ultrafiltration and ultrafiltration with dialysis
-
van der Sande FM, Mulder AW, Hoorntje SJ, et al: The hemodynamic effect of different ultrafiltration rates in patients with cardiac failure and patients without cardiac failure: comparison between isolated ultrafiltration and ultrafiltration with dialysis. Clin Nephrol 50: 301-308, 1998.
-
(1998)
Clin Nephrol
, vol.50
, pp. 301-308
-
-
van der Sande, F.M.1
Mulder, A.W.2
Hoorntje, S.J.3
-
25
-
-
19544369477
-
Noninvasive monitoring of hemodynamic changes during hemodialysis by the use of a newly developed admittance cardiograph
-
Yoshii M, Minami J, Ishimitsu T, Yamakoshi K, Matsuoka H: Noninvasive monitoring of hemodynamic changes during hemodialysis by the use of a newly developed admittance cardiograph. Ther Apher Dial 9: 154-160, 2005.
-
(2005)
Ther Apher Dial
, vol.9
, pp. 154-160
-
-
Yoshii, M.1
Minami, J.2
Ishimitsu, T.3
Yamakoshi, K.4
Matsuoka, H.5
-
26
-
-
1642520787
-
Body mass index, dialysis modality, and survival: Analysis of the United States Renal Data System Dialysis Morbidity and Mortality Wave II Study
-
Abbott KC, Glanton CW, Trespalacios FC, et al: Body mass index, dialysis modality, and survival: analysis of the United States Renal Data System Dialysis Morbidity and Mortality Wave II Study. Kidney Int 65: 597-605, 2004.
-
(2004)
Kidney Int
, vol.65
, pp. 597-605
-
-
Abbott, K.C.1
Glanton, C.W.2
Trespalacios, F.C.3
-
27
-
-
15744384336
-
Survival advantages of obesity in dialysis patients
-
Kalantar-Zadeh K, Abbott KC, Salahudeen AK, Kilpatrick RD and Horwich TB: Survival advantages of obesity in dialysis patients. Am J Clin Nutr 81: 543-554, 2005.
-
(2005)
Am J Clin Nutr
, vol.81
, pp. 543-554
-
-
Kalantar-Zadeh, K.1
Abbott, K.C.2
Salahudeen, A.K.3
Kilpatrick, R.D.4
Horwich, T.B.5
-
28
-
-
33748059224
-
Obesity paradox in patients on maintenance dialysis
-
Kalantar-Zadeh K, Kopple JD: Obesity paradox in patients on maintenance dialysis. Contrib Nephrol 151: 57-69, 2006.
-
(2006)
Contrib Nephrol
, vol.151
, pp. 57-69
-
-
Kalantar-Zadeh, K.1
Kopple, J.D.2
-
29
-
-
33845731264
-
Size matters: Body composition and outcomes in maintenance hemodialysis patients
-
Kotanko P, Thijssen S, Kitzler T, et al: Size matters: body composition and outcomes in maintenance hemodialysis patients. Blood Purif 25: 27-30, 2007.
-
(2007)
Blood Purif
, vol.25
, pp. 27-30
-
-
Kotanko, P.1
Thijssen, S.2
Kitzler, T.3
|