-
2
-
-
0000696490
-
The blood supply of various skin areas as estimated by the photoelectric plethysmograph
-
A. B. Hertzman, "The blood supply of various skin areas as estimated by the photoelectric plethysmograph," Am. J. Physiol., vol. 124, pp. 328-340, 1938.
-
(1938)
Am. J. Physiol
, vol.124
, pp. 328-340
-
-
Hertzman, A.B.1
-
3
-
-
0742303088
-
Design of filter to reject motion artifact, of pulse oximetry
-
J. Lee, W. Jung, I. Rang, Y. Kim and G. Lee, "Design of filter to reject motion artifact, of pulse oximetry," Computer Standards and Interfaces, vol. 26, no. 3, pp. 241-249, 2004.
-
(2004)
Computer Standards and Interfaces
, vol.26
, Issue.3
, pp. 241-249
-
-
Lee, J.1
Jung, W.2
Rang, I.3
Kim, Y.4
Lee, G.5
-
4
-
-
18044373423
-
Reduction of motion artifact in pulse oximetry by smoothed pseudo wigner-ville distribution
-
available from
-
Y. S. Yan, C. C. Poon and Y. T. Zhang, "Reduction of motion artifact in pulse oximetry by smoothed pseudo wigner-ville distribution," J Neuroengineering Rehabil., 2005, 2:3, available from http://www. jneuroengrehab.eom/content/2/1/3
-
(2005)
J Neuroengineering Rehabil
, vol.2
, pp. 3
-
-
Yan, Y.S.1
Poon, C.C.2
Zhang, Y.T.3
-
5
-
-
84945972291
-
Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach
-
20-22 Oct
-
C. M. Lee and Y. T. Zhang, "Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach," in Proc. IEEE EMBS Asian-Pacific Conf. on Biomed. Engg, pp. 194-195, 20-22 Oct. 2003.
-
(2003)
Proc. IEEE EMBS Asian-Pacific Conf. on Biomed. Engg
, pp. 194-195
-
-
Lee, C.M.1
Zhang, Y.T.2
-
6
-
-
33344472354
-
Motion artifact reduction in photoplethysmography using independent, component analysis
-
B. S. Kim and S. K. Yoo, "Motion artifact reduction in photoplethysmography using independent, component analysis," IEEE Trans. Biomed Engg., vol. 53, no. 3, pp. 566-568, 2006.
-
(2006)
IEEE Trans. Biomed Engg
, vol.53
, Issue.3
, pp. 566-568
-
-
Kim, B.S.1
Yoo, S.K.2
-
7
-
-
33846904578
-
A short study to assess the potential of independent component analysis for motion artifact separation in wearable pulse oximeter signals
-
1-4 Sept
-
th Annual Conf. IEEE Engg. Medicine and Biology, pp. 3585-3588, 1-4 Sept. 2005.
-
(2005)
th Annual Conf. IEEE Engg. Medicine and Biology
, pp. 3585-3588
-
-
Yao, J.1
Warren, S.2
-
8
-
-
33746981904
-
Comparison of wavelet transformation and adaptive filtering in restoring artifact-induced time-related measurement
-
J. Y. A. Foo, "Comparison of wavelet transformation and adaptive filtering in restoring artifact-induced time-related measurement," Biomedical signal processing and control, vol. 1, issue 1, pp. 93-98, 2006.
-
(2006)
Biomedical signal processing and control
, vol.1
, Issue.1
, pp. 93-98
-
-
Foo, J.Y.A.1
-
9
-
-
0019009028
-
The singular value decomposition: Its computation and some applications
-
V. C. Klema and A. J. Laub, "The singular value decomposition: Its computation and some applications," IEEE Trans. Autom. Control., vol. AC-25, no. 2, pp. 164-176, 1980.
-
(1980)
IEEE Trans. Autom. Control
, vol.AC-25
, Issue.2
, pp. 164-176
-
-
Klema, V.C.1
Laub, A.J.2
-
10
-
-
0029325543
-
On multiple pattern extraction using singular value decomposition
-
P. P. Kanjilal and S. Palit, "On multiple pattern extraction using singular value decomposition," IEEE Trans. Signal. Process. , vol. 43, no. 6, pp. 1536-1540, 1995.
-
(1995)
IEEE Trans. Signal. Process
, vol.43
, Issue.6
, pp. 1536-1540
-
-
Kanjilal, P.P.1
Palit, S.2
-
11
-
-
34648856092
-
Virtual instrument for the measurement of haemo-dynamic parameters using photoplethysmograph
-
24-27 April
-
K. A. Reddy, J. R. Bai, B. George, N. M. Mohan and V. J. Kumar, "Virtual instrument for the measurement of haemo-dynamic parameters using photoplethysmograph," in Proc. IEEE, IMTC-2006, pp. 1167-1171, 24-27 April, 2006.
-
(2006)
Proc. IEEE, IMTC-2006
, pp. 1167-1171
-
-
Reddy, K.A.1
Bai, J.R.2
George, B.3
Mohan, N.M.4
Kumar, V.J.5
-
12
-
-
17644411028
-
Extinction coefficients of hemoglobin for near-infrared spectroscopy of tissue
-
March/April
-
J. G. Kim, M. Xia, and H. Liu, "Extinction coefficients of hemoglobin for near-infrared spectroscopy of tissue," IEEE Eng. Med. Biol. Mag, vol. 24, no. 2, pp. 118-121, March/April 2005.
-
(2005)
IEEE Eng. Med. Biol. Mag
, vol.24
, Issue.2
, pp. 118-121
-
-
Kim, J.G.1
Xia, M.2
Liu, H.3
|