메뉴 건너뛰기




Volumn 7 VOLS, Issue , 2005, Pages 3585-3588

A short study to assess the potential of independent component analysis for motion artifact separation in wearable pulse oximeter signals

Author keywords

Independent component analysis; Motion artifacts; Pulse oximetry; Wearable sensors

Indexed keywords

BIOSENSORS; INDEPENDENT COMPONENT ANALYSIS; PATIENT MONITORING; PLETHYSMOGRAPHY; SIGNAL PROCESSING;

EID: 33846904578     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (76)

References (15)
  • 1
    • 33846934373 scopus 로고    scopus 로고
    • Yoo, S.K, Photoplethysmography (PPG) device and the method thereof. 2005: U.S. patent
    • Yoo, S.K., Photoplethysmography (PPG) device and the method thereof. 2005: U.S. patent.
  • 2
    • 35048882938 scopus 로고    scopus 로고
    • Independent Component Analysis of Pulse Oximetry Signals Based on Derivative Skew
    • Granada, Spain: Springer, p
    • Stetson, P.F. Independent Component Analysis of Pulse Oximetry Signals Based on Derivative Skew. in the Fifth International Conference on Independent Component Analysis. 2004. Granada, Spain: Springer, p. 1072-1078
    • (2004) the Fifth International Conference on Independent Component Analysis , pp. 1072-1078
    • Stetson, P.F.1
  • 3
    • 11144327119 scopus 로고    scopus 로고
    • A Novel Algorithm to Separate Motion Artifacts from the Photoplethysmographic Signal for a Pulse Oximeter
    • San Francisco, CA. p
    • Yao, J. and S. Warren. A Novel Algorithm to Separate Motion Artifacts from the Photoplethysmographic Signal for a Pulse Oximeter. in 4th Joint EMBS-BMES Conf. 2004. San Francisco, CA. p. 2153-2156.
    • (2004) 4th Joint EMBS-BMES Conf , pp. 2153-2156
    • Yao, J.1    Warren, S.2
  • 4
    • 0035073348 scopus 로고    scopus 로고
    • A New Method for Pulse Oximetry Possessing Inherent Insensitivity to Artifact
    • Hayes, M.J. and P.R. Smith, A New Method for Pulse Oximetry Possessing Inherent Insensitivity to Artifact. IEEE Transactions on Biomedical Engineering, 2001. 48(4): p. 452-461.
    • (2001) IEEE Transactions on Biomedical Engineering , vol.48 , Issue.4 , pp. 452-461
    • Hayes, M.J.1    Smith, P.R.2
  • 5
    • 0034968268 scopus 로고    scopus 로고
    • Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
    • Rhee, S., B.-H. Yang, and H. H. Asada, Artifact-resistant power-efficient design of finger-ring plethysmographic sensors. IEEE Transactions on Biomedical Engineering, 2001. 48(7): p. 795-805.
    • (2001) IEEE Transactions on Biomedical Engineering , vol.48 , Issue.7 , pp. 795-805
    • Rhee, S.1    Yang, B.-H.2    Asada, H.H.3
  • 6
    • 33846913823 scopus 로고    scopus 로고
    • Stetson, P.F, Blind source separation of pulse oximetry signals. 2004, Nellcor Puritan Bennett Inc, U.S. patent
    • Stetson, P.F., Blind source separation of pulse oximetry signals. 2004, Nellcor Puritan Bennett Inc.: U.S. patent.
  • 7
    • 33846933423 scopus 로고    scopus 로고
    • Blind source separation of pulse oximetry signals
    • Patent Application Publication US2003/0088164: United States
    • Stetson, P.F., Blind source separation of pulse oximetry signals. 2003, Patent Application Publication US2003/0088164: United States.
    • (2003)
    • Stetson, P.F.1
  • 8
    • 0031239460 scopus 로고    scopus 로고
    • Extraction of ocular artifacts from EEG using independent component analysis
    • Vigario, R., Extraction of ocular artifacts from EEG using independent component analysis. Electroenceph, clin. Neurophysiol., 1997. 103(3): p. 395-404.
    • (1997) Electroenceph, clin. Neurophysiol , vol.103 , Issue.3 , pp. 395-404
    • Vigario, R.1
  • 9
    • 0034108247 scopus 로고    scopus 로고
    • Removing electroencephalographic artifacts by blind source separation
    • Jung, T.-P., et al., Removing electroencephalographic artifacts by blind source separation. Psychophysiology, 2000. 37: p. 163-178.
    • (2000) Psychophysiology , vol.37 , pp. 163-178
    • Jung, T.-P.1
  • 10
    • 0007210208 scopus 로고    scopus 로고
    • Transiently time-locked fMRI activations revealed by independent components analysis
    • Makeig, S., et al. Transiently time-locked fMRI activations revealed by independent components analysis. in Proceedings of the National Academy of Sciences. 1997. p. 803-810.
    • (1997) Proceedings of the National Academy of Sciences , pp. 803-810
    • Makeig, S.1
  • 11
    • 33846900361 scopus 로고    scopus 로고
    • The FastICA package for MATLAB
    • "The FastICA package for MATLAB," http://www.cis.hut.fi/ projects/ica/fastica/
  • 12
    • 0018924654 scopus 로고
    • Spectrophotometric monitoring of arterial oxygen saturation in the fingertip
    • Yoshiya, Y.S. and K. Tanaka, Spectrophotometric monitoring of arterial oxygen saturation in the fingertip. Med. Biol. Eng. Comput., 1980. 18: p. 27-32.
    • (1980) Med. Biol. Eng. Comput , vol.18 , pp. 27-32
    • Yoshiya, Y.S.1    Tanaka, K.2
  • 13
    • 33846931719 scopus 로고    scopus 로고
    • Technical Bulletin, Signal Extraction Technology®
    • "Technical Bulletin - Signal Extraction Technology®," http://www.masimo.com/IMAGES/tcchnology/lab1035.pdf
  • 14
    • 33846929320 scopus 로고    scopus 로고
    • Hemodynamic Measurement Terminology
    • Rnceus. "Hemodynamic Measurement Terminology," http://www.rnceus.com/hemo/term.htm
    • Rnceus1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.