메뉴 건너뛰기




Volumn 14, Issue 5, 2007, Pages 432-437

Tests of platelet function

Author keywords

Electron microscopy; Flow cytometry; PFA 100; Platelet aggregation; Platelet function; Platelet secretion

Indexed keywords

ABCIXIMAB; ADENINE NUCLEOTIDE; ANTITHROMBOCYTIC AGENT; CLOPIDOGREL; EPTIFIBATIDE; RISTOCETIN; THROMBOXANE RECEPTOR STIMULATING AGENT; TICLOPIDINE; TIROFIBAN; U 46612; UNCLASSIFIED DRUG; VASODILATOR AGENT;

EID: 34648815153     PISSN: 10656251     EISSN: 15317048     Source Type: Journal    
DOI: 10.1097/MOH.0b013e3282b9747b     Document Type: Review
Times cited : (34)

References (39)
  • 1
    • 33751114620 scopus 로고    scopus 로고
    • Michaelson A, editor, 2nd ed. New York: Academic Press;, A comprehensive and fairly updated review of platelet function testing in addition to disorders of platelet function
    • Michaelson A, editor. Platelets. 2nd ed. New York: Academic Press; 2006. A comprehensive and fairly updated review of platelet function testing in addition to disorders of platelet function.
    • (2006) Platelets
  • 2
    • 0020619235 scopus 로고
    • Duke and his bleeding time test: A commentary on platelet function
    • Brinkhous KM. W. W. Duke and his bleeding time test: a commentary on platelet function. JAMA 1983; 250:1210-1214.
    • (1983) JAMA , vol.250 , pp. 1210-1214
    • Brinkhous, K.W.W.1
  • 3
    • 33746602713 scopus 로고    scopus 로고
    • Favaloro EJ. Laboratory identification of von Willebrand disease: technical and scientific perspectives. Semin Thromb Hemost 2006; 32:456-471. An excellent review of the limitations and strengths of the PFA-100.
    • Favaloro EJ. Laboratory identification of von Willebrand disease: technical and scientific perspectives. Semin Thromb Hemost 2006; 32:456-471. An excellent review of the limitations and strengths of the PFA-100.
  • 4
    • 0031892624 scopus 로고    scopus 로고
    • The preoperative bleeding time test lacks clinical benefit: College of American Pathologists' and American Society of Clinical Pathologists' position article
    • Peterson P, Hayes TE, Arkin CF, et al. The preoperative bleeding time test lacks clinical benefit: College of American Pathologists' and American Society of Clinical Pathologists' position article. Arch Surg 1998; 133:134-139.
    • (1998) Arch Surg , vol.133 , pp. 134-139
    • Peterson, P.1    Hayes, T.E.2    Arkin, C.F.3
  • 5
    • 0021186345 scopus 로고
    • Prolonged bleeding time
    • Lind SE. Prolonged bleeding time. Am J Med 1984; 77:305-312.
    • (1984) Am J Med , vol.77 , pp. 305-312
    • Lind, S.E.1
  • 6
    • 0022356309 scopus 로고
    • Simulation of primary haemostasis in vitro
    • Kratzer MA, Born GV. Simulation of primary haemostasis in vitro. Haemostasis 1985; 15:357-362.
    • (1985) Haemostasis , vol.15 , pp. 357-362
    • Kratzer, M.A.1    Born, G.V.2
  • 7
    • 0029011142 scopus 로고
    • Description of an in vitro platelet function analyzer: PFA-100
    • Kundu SK, Heilmann EJ, Sio R, et al. Description of an in vitro platelet function analyzer: PFA-100. Semin Thromb Hemost 1995; 21 (Suppl 2):106-112.
    • (1995) Semin Thromb Hemost , vol.21 , Issue.SUPPL. 2 , pp. 106-112
    • Kundu, S.K.1    Heilmann, E.J.2    Sio, R.3
  • 8
    • 0029034485 scopus 로고    scopus 로고
    • Mammen EF, Alshameeri RS, Comp PC. Preliminary data from a field trial of the PFA-100 system. Semin Thromb Hemost 1995; 21 (Suppl 2):113-121.
    • Mammen EF, Alshameeri RS, Comp PC. Preliminary data from a field trial of the PFA-100 system. Semin Thromb Hemost 1995; 21 (Suppl 2):113-121.
  • 9
    • 27244434958 scopus 로고    scopus 로고
    • Variables influencing platelet function analyzer-100 closure times in healthy individuals
    • Haubelt H, Anders C, Vogt A, et al. Variables influencing platelet function analyzer-100 closure times in healthy individuals. Br J Haematol 2005; 130:759-767.
    • (2005) Br J Haematol , vol.130 , pp. 759-767
    • Haubelt, H.1    Anders, C.2    Vogt, A.3
  • 10
    • 25144504902 scopus 로고    scopus 로고
    • The platelet-function analyzer (PFA-100) for evaluating primary hemostasis
    • Franchini M. The platelet-function analyzer (PFA-100) for evaluating primary hemostasis. Hematology 2005; 10:177-181.
    • (2005) Hematology , vol.10 , pp. 177-181
    • Franchini, M.1
  • 11
    • 22144455398 scopus 로고    scopus 로고
    • The role of PFA-100 testing in the investigation and management of haemostatic defects in children and adults
    • Harrison P. The role of PFA-100 testing in the investigation and management of haemostatic defects in children and adults. Br J Haematol 2005; 130:3-10.
    • (2005) Br J Haematol , vol.130 , pp. 3-10
    • Harrison, P.1
  • 12
    • 0032755649 scopus 로고    scopus 로고
    • The relationship between the onset of labor mechanisms and the hemostatic system
    • Suzuki S, Morishita S. The relationship between the onset of labor mechanisms and the hemostatic system. Immunopharmacology 1999; 43:133-140.
    • (1999) Immunopharmacology , vol.43 , pp. 133-140
    • Suzuki, S.1    Morishita, S.2
  • 13
    • 33645557848 scopus 로고    scopus 로고
    • Hayward CP, Harrison P, Cattaneo M, et al. Platelet function analyzer (PFA)-100 closure time in the evaluation of platelet disorders and platelet function. J Thromb Haemost 2006; 4:312-319. A systematic review of the use of the PFA-100 in evaluating platelet disorders, by the Platelet Physiology Subcommittee of the Scientific and Standardization Committee of the International Society of Thrombosis and Haemostasis.
    • Hayward CP, Harrison P, Cattaneo M, et al. Platelet function analyzer (PFA)-100 closure time in the evaluation of platelet disorders and platelet function. J Thromb Haemost 2006; 4:312-319. A systematic review of the use of the PFA-100 in evaluating platelet disorders, by the Platelet Physiology Subcommittee of the Scientific and Standardization Committee of the International Society of Thrombosis and Haemostasis.
  • 14
    • 33746650150 scopus 로고    scopus 로고
    • The utility of the PFA-100 in the identification of von Willebrand disease: A concise review
    • Semin Thromb Hemost, 100 in diagnosing vWD
    • Favaloro EJ. The utility of the PFA-100 in the identification of von Willebrand disease: a concise review. Semin Thromb Hemost 2006; 32:537-545. Reviews the studies of the use of the PFA-100 in diagnosing vWD.
    • (2006) Reviews the studies of the use of the PFA , vol.32 , pp. 537-545
    • Favaloro, E.J.1
  • 15
    • 0036344893 scopus 로고    scopus 로고
    • Clinical application of the PFA-100
    • Favaloro EJ. Clinical application of the PFA-100. Curr Opin Hematol 2002; 9:407-415.
    • (2002) Curr Opin Hematol , vol.9 , pp. 407-415
    • Favaloro, E.J.1
  • 16
    • 3242755862 scopus 로고    scopus 로고
    • A practical concept for preoperative identification of patients with impaired primary hemostasis
    • Koscielny J, Ziemer S, Radtke H, et al. A practical concept for preoperative identification of patients with impaired primary hemostasis. Clin Appl Thromb Hemost 2004; 10:195-204.
    • (2004) Clin Appl Thromb Hemost , vol.10 , pp. 195-204
    • Koscielny, J.1    Ziemer, S.2    Radtke, H.3
  • 17
    • 1842852176 scopus 로고    scopus 로고
    • A practical concept for preoperative management of patients with impaired primary hemostasis
    • Koscielny J, von Tempelhoff GF, Ziemer S, et al. A practical concept for preoperative management of patients with impaired primary hemostasis. Clin Appl Thromb Hemost 2004; 10:155-166.
    • (2004) Clin Appl Thromb Hemost , vol.10 , pp. 155-166
    • Koscielny, J.1    von Tempelhoff, G.F.2    Ziemer, S.3
  • 19
    • 34247868876 scopus 로고    scopus 로고
    • Examination of platelet function in whole blood under dynamic flow conditions with the cone and plate(let) analyzer: Effect of erythrocytosis and thrombocytosis
    • Peerschke EI, Silver RT, Weksler BB, et al. Examination of platelet function in whole blood under dynamic flow conditions with the cone and plate(let) analyzer: effect of erythrocytosis and thrombocytosis. Am J Clin Pathol 2007; 127:422-428.
    • (2007) Am J Clin Pathol , vol.127 , pp. 422-428
    • Peerschke, E.I.1    Silver, R.T.2    Weksler, B.B.3
  • 20
    • 33748452702 scopus 로고    scopus 로고
    • Impact: The cone and plate(let) analyzer: testing platelet function and antiplatelet drug response
    • Savion N, Varon D. Impact: the cone and plate(let) analyzer: testing platelet function and antiplatelet drug response. Pathophysiol Haemost Thromb 2006; 35:83-88.
    • (2006) Pathophysiol Haemost Thromb , vol.35 , pp. 83-88
    • Savion, N.1    Varon, D.2
  • 21
    • 34247170406 scopus 로고    scopus 로고
    • Platelet function testing: Aggregometry and lumiaggregometry
    • Fritsma GA. Platelet function testing: aggregometry and lumiaggregometry. Clin Lab Sci 2007; 20:32-37.
    • (2007) Clin Lab Sci , vol.20 , pp. 32-37
    • Fritsma, G.A.1
  • 22
    • 0026563004 scopus 로고
    • Assessment of lumiaggregometry for research and clinical laboratories
    • White MM, Foust JT, Mauer AM, et al. Assessment of lumiaggregometry for research and clinical laboratories. Thromb Haemost 1992; 67:572-577.
    • (1992) Thromb Haemost , vol.67 , pp. 572-577
    • White, M.M.1    Foust, J.T.2    Mauer, A.M.3
  • 23
    • 13244292463 scopus 로고    scopus 로고
    • Platelet aggregation testing in platelet-rich plasma: Description of procedures with the aim to develop standards in the field
    • Zhou L, Schmaier AH. Platelet aggregation testing in platelet-rich plasma: description of procedures with the aim to develop standards in the field. Am J Clin Pathol 2005; 123:172-183.
    • (2005) Am J Clin Pathol , vol.123 , pp. 172-183
    • Zhou, L.1    Schmaier, A.H.2
  • 24
    • 0023932918 scopus 로고
    • Platelet volume and intraplatelet adenine nucleotides in various hematologic disorders
    • Nozaki H, Nagao T, Arimori S. Platelet volume and intraplatelet adenine nucleotides in various hematologic disorders. Eur J Haematol 1988; 40:65-68.
    • (1988) Eur J Haematol , vol.40 , pp. 65-68
    • Nozaki, H.1    Nagao, T.2    Arimori, S.3
  • 25
    • 0033302953 scopus 로고    scopus 로고
    • Laboratory markers of platelet activation and their clinical significance
    • Michelson AD, Furman MI. Laboratory markers of platelet activation and their clinical significance. Curr Opin Hematol 1999; 6:342-348.
    • (1999) Curr Opin Hematol , vol.6 , pp. 342-348
    • Michelson, A.D.1    Furman, M.I.2
  • 26
    • 3042561898 scopus 로고    scopus 로고
    • P-selectin and antibodies against heparin-platelet factor 4 in patients with venous or arterial diseases after a 7-day heparin treatment
    • Papalambros E, Sigala F, Travlou A, et al. P-selectin and antibodies against heparin-platelet factor 4 in patients with venous or arterial diseases after a 7-day heparin treatment. J Am Coll Surg 2004; 199:69-77.
    • (2004) J Am Coll Surg , vol.199 , pp. 69-77
    • Papalambros, E.1    Sigala, F.2    Travlou, A.3
  • 27
    • 10444228879 scopus 로고    scopus 로고
    • Platelet function analysis
    • Harrison P. Platelet function analysis. Blood Rev 2005; 19:111-123.
    • (2005) Blood Rev , vol.19 , pp. 111-123
    • Harrison, P.1
  • 28
    • 0035888583 scopus 로고    scopus 로고
    • Comparison between different laboratory tests for the detection and prevention of heparin-induced thrombocytopenia
    • Vitale M, Tazzari P, Ricci F, et al. Comparison between different laboratory tests for the detection and prevention of heparin-induced thrombocytopenia. Cytometry 2001; 46:290-295.
    • (2001) Cytometry , vol.46 , pp. 290-295
    • Vitale, M.1    Tazzari, P.2    Ricci, F.3
  • 29
    • 0032863073 scopus 로고    scopus 로고
    • A flow cytometric assay of platelet activation marker P-selectin (CD62P) distinguishes heparin-induced thrombocytopenia (HIT) from HIT with thrombosis (HITT)
    • Jy W, Mao WW, Horstman LL, et al. A flow cytometric assay of platelet activation marker P-selectin (CD62P) distinguishes heparin-induced thrombocytopenia (HIT) from HIT with thrombosis (HITT). Thromb Haemost 1999; 82:1255-1259.
    • (1999) Thromb Haemost , vol.82 , pp. 1255-1259
    • Jy, W.1    Mao, W.W.2    Horstman, L.L.3
  • 31
    • 0037220690 scopus 로고    scopus 로고
    • The predictive value of modified computerized thromboelastography and platelet function analysis for post-operative blood loss in routine cardiac surgery
    • Cammerer U, Dietrich W, Rampf T, et al. The predictive value of modified computerized thromboelastography and platelet function analysis for post-operative blood loss in routine cardiac surgery. Anesth Analg 2003; 96:51-57.
    • (2003) Anesth Analg , vol.96 , pp. 51-57
    • Cammerer, U.1    Dietrich, W.2    Rampf, T.3
  • 32
    • 0021815571 scopus 로고
    • Intraoperative changes in blood coagulation and thrombelastographic monitoring in liver transplantation
    • Kang YG, Martin DJ, Marquez J, et al. Intraoperative changes in blood coagulation and thrombelastographic monitoring in liver transplantation. Anesth Analg 1985; 64:888-896.
    • (1985) Anesth Analg , vol.64 , pp. 888-896
    • Kang, Y.G.1    Martin, D.J.2    Marquez, J.3
  • 33
    • 0023133536 scopus 로고
    • Thromboelastography as an indicator of postcardiopulmonary bypass coagulopathies
    • Spiess BD, Tuman KJ, McCarthy RJ, et al. Thromboelastography as an indicator of postcardiopulmonary bypass coagulopathies. J Clin Monit 1987; 3:25-30.
    • (1987) J Clin Monit , vol.3 , pp. 25-30
    • Spiess, B.D.1    Tuman, K.J.2    McCarthy, R.J.3
  • 34
    • 33751546229 scopus 로고    scopus 로고
    • Thrombelastography: Current clinical applications and its potential role in interventional cardiology
    • Hobson AR, Agarwala RA, Swallow RA, et al. Thrombelastography: current clinical applications and its potential role in interventional cardiology. Platelets 2006; 17:509-518.
    • (2006) Platelets , vol.17 , pp. 509-518
    • Hobson, A.R.1    Agarwala, R.A.2    Swallow, R.A.3
  • 35
    • 0019730084 scopus 로고
    • Comparison of thrombelastography with common coagulation tests
    • Zuckerman L, Cohen E, Vagher JP, et al. Comparison of thrombelastography with common coagulation tests. Thromb Haemost 1981; 46:752-756.
    • (1981) Thromb Haemost , vol.46 , pp. 752-756
    • Zuckerman, L.1    Cohen, E.2    Vagher, J.P.3
  • 36
    • 0029616069 scopus 로고
    • Application of thromboelastography in other medical and surgical states
    • Traverso CI, Caprini JA, Arcelus JI. Application of thromboelastography in other medical and surgical states. Semin Thromb Hemost 1995; 21 (Suppl 4):50-52.
    • (1995) Semin Thromb Hemost , vol.21 , Issue.SUPPL. 4 , pp. 50-52
    • Traverso, C.I.1    Caprini, J.A.2    Arcelus, J.I.3
  • 37
    • 0031952881 scopus 로고    scopus 로고
    • Use of the electron microscope for diagnosis of platelet disorders
    • White JG. Use of the electron microscope for diagnosis of platelet disorders. Semin Thromb Hemost 1998; 24:163-168.
    • (1998) Semin Thromb Hemost , vol.24 , pp. 163-168
    • White, J.G.1
  • 38
    • 0018720044 scopus 로고
    • Storage pool disease: Comparative fluorescence microscopical, cytochemical and biochemical studies on aminestoring organelles of human blood platelets
    • Lorez HP, Richards JG, Da Prada M, et al. Storage pool disease: comparative fluorescence microscopical, cytochemical and biochemical studies on aminestoring organelles of human blood platelets. Br J Haematol 1979; 43:297-305.
    • (1979) Br J Haematol , vol.43 , pp. 297-305
    • Lorez, H.P.1    Richards, J.G.2    Da Prada, M.3
  • 39
    • 0037910378 scopus 로고    scopus 로고
    • MYH9-related disease: May-Hegglin anomaly, Sebastian syndrome, Fechtner syndrome, and Epstein syndrome are not distinct entities but represent a variable expression of a single illness
    • Seri M, Pecci A, Di Bari F, et al. MYH9-related disease: May-Hegglin anomaly, Sebastian syndrome, Fechtner syndrome, and Epstein syndrome are not distinct entities but represent a variable expression of a single illness. Medicine (Baltimore) 2003; 82:203-215.
    • (2003) Medicine (Baltimore) , vol.82 , pp. 203-215
    • Seri, M.1    Pecci, A.2    Di Bari, F.3